• 제목/요약/키워드: Operating performance

검색결과 6,505건 처리시간 0.032초

Effect of LiCoO2-Coated Cathode on Performance of Molten Carbonate Fuel Cell

  • Kim, Dohyeong;Kim, Hyung Tae;Song, Shin Ae;Kim, Kiyoung;Lim, Sung Nam;Woo, Ju Young;Han, Haksoo
    • Journal of Electrochemical Science and Technology
    • /
    • 제13권1호
    • /
    • pp.112-119
    • /
    • 2022
  • Molten carbonate fuel cells (MCFCs) are environmentally friendly, large-capacity power generation devices operated at approximately 650℃. If MCFCs are to be commercialized by improving their competitiveness, their cell life should be increased by operating them at lower temperatures. However, a decrease in the operating temperature causes a reduction in the cell performance because of the reduction in the electrochemical reaction rate. The cell performance can be improved by introducing a coating on the cathode of the cell. A coating with a high surface area expands the triple phase boundaries (TPBs) where the gas and electrolyte meet on the electrode surface. And the expansion of TPBs enhances the oxygen reduction reaction of the cathode. Therefore, the cell performance can be improved by increasing the reaction area, which can be achieved by coating nanosized LiCoO2 particles on the cathode. However, although a coating improves the cell performance, a thick coating makes gas difficult to diffuse into the pore of the coating and thus reduces the cell performance. In addition, LiCoO2-coated cathode cell exhibits stable cell performance because the coating layer maintains a uniform thickness under MCFC operating conditions. Therefore, the performance and stability of MCFCs can be improved by applying a LiCoO2 coating with an appropriate thickness on the cathode.

난류영역에서 운전되는 유한폭 저어널베어링에서의 성능특성에 관한 실험적 연구 (Experimental Study on the Performance of Finite Journal Bearing Operting in Turbulent Regime)

  • 이득우;김경웅
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1991년도 제14회 학술강연회초록집
    • /
    • pp.14-21
    • /
    • 1991
  • The performance of finite journal bearing operating in turbulent regime was experimentally investigated. In order to obtain experimental data contained operating conditions(thermal deformation etc.) of bearing, this study measured the pressure and the film thickness with sensors mounted on the journal. And, the continuous pressure profile and the film thickness profile were obtained.

  • PDF

터미날 화면의 설계 특성에 관한 비교분석 (The analysis on the screen design of terminal display)

  • 황우상;이동춘
    • 대한인간공학회:학술대회논문집
    • /
    • 대한인간공학회 1995년도 추계학술대회논문집
    • /
    • pp.62-74
    • /
    • 1995
  • This study surveys four characteristics (overall density, local density, grouping, complexity) to effect user's performance on the on-line terminal displays of commercial banks, and makes the new screen by the screen design procedure. The new screen includes to increase the number of groups and to arrange the items on the screen. And then, this study carrys out experiments to compare performance(operating time and error number ) by each screen. The result is described that the operating time decreases about 20% at the new OUT-screen than the existing OUT-screens; about 25% at the new IN-screen.

  • PDF

난류영역에서 운전되는 유한폭 저어널베어링에서의 성능특성에 관한 실험적 연구 (Experimental Study on the Performance of Finite Bearing Operating in Turbulent Regime)

  • 이득우;김경웅
    • Tribology and Lubricants
    • /
    • 제8권1호
    • /
    • pp.44-47
    • /
    • 1992
  • The performance of finite journal bearing operating in turbulent regime was investigated experimentally. In order to obtain experimental data containing surrounding conditions (thermal deformation, machining error etc.) of journal bearing, this study mounted a pressure sensor and a gap sensor on the journal. The data for continuous pressure profile and continuous film thickness profile were presented in this paper.

Three buffer 맥동관 냉동기에 관한 실험적 연구 (An Experimental Study of Three Buffer Pulse Tube Refrigerator)

  • 박성제;고득용;김효봉;신완순
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 1999년도 제1회 학술대회논문집(KIASC 1st conference 99)
    • /
    • pp.189-193
    • /
    • 1999
  • An experimental study was carried out to improve the cooling capacity and performance of the pulse tube refrigerator. Three buffer pulse tube refrigerator was designed and fabricated, and the experimental apparatus was constructed. This paper presents operating process of three buffer pulse tube refrigerator and results obtained with the performance test. The cooldown characteristics and load characteristics are described. The lowest temperature measured in three pulse tube refrigerator was 88K and the cooling capacity at the optimum operating condition was 27W at 120K.

  • PDF

Three Buffer 맥동관 냉동기에 관한 실험적 연구 (An Experimental Study of a Therr Buffer Pulse Tube Refrigerator)

  • 박성재;고득용;김효봉;신완순
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제1권2호
    • /
    • pp.54-59
    • /
    • 1999
  • An experimental study was carried out to improve the cooling capacity and performance of the pulse tube refrigerator. Three buffer pulse tube refrigerator was designed and fabricated, and the experimental apparatus operating process of the therr buffer pulse tube refrigerator and results obtained with the performance test. The cooldown characteristics and load characteristics are described. The lowest temperature measured in the three buffer pulse tube refrigerator was 88K and the cooling capacity at the optimum operating condition was 27 W at 120K.

  • PDF

적외선 센서 냉각용 스터링 냉동기의 성능시험 (Performance Test of the Stirling Cryocooler for Cooling of the Infrared Detectors)

  • 고득용;박성제;김효봉;염한길;김홍국;김남환
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 1999년도 제1회 학술대회논문집(KIASC 1st conference 99)
    • /
    • pp.202-206
    • /
    • 1999
  • This paper presents operating process of the Stirling cryocooler and results obtained with the performance test for Signal Usfa UP 7075 Stirling cryocooler. An experimental study was carried out to develop the more reliable Stirling cryocooler. The cooldown characteristics and load characteristics are described. The lowest temperature measured in the Stirling cryocooler wa 62.5K and the cooling capacity at the optimum operating condition was 0.4W at 77K. At that time, carnot COP was 0.024.

  • PDF

우리나라 기업의 e-비즈니스 시스템 도입현황과 성과 : 실증분석 (E-Business, Firm Characteristics and Firm Performance : An Empirical Analysis of Korean Firms)

  • 성낙일;김민창;서성우
    • Journal of Information Technology Applications and Management
    • /
    • 제18권4호
    • /
    • pp.55-79
    • /
    • 2011
  • This study attempts to examine the factors affecting the introduction of e-Business systems and also, to assess the effects of various e-Business systems on firm performance. Empirical analysis is carried out with firm data of 2009, which is collected from Firm Activity Survey of Statistics Korea. Firm performance is measured by four indexes; operating income per employee, value added per employee, return on assets, and return on sales. Empirical results indicate that a firm is more likely to introduce any e-Business system as its size and its assets per employee are larger and as its ratio of labor compensations to operating costs is lower. Additionally, a firm with higher skill levels and more fruitful management experiences is more likely to have any e-Business system. In general, it appears that the presence of e-Business, especially enterprise resources planning, has positive effects on the firm performance.

지방의료원의 경영성과에 미치는 영향 (Factors Affecting the Performance of Local Public Hospitals)

  • 양종현;이정우
    • 보건의료산업학회지
    • /
    • 제11권3호
    • /
    • pp.1-11
    • /
    • 2017
  • Objectives : The purpose of this study was to analyze factors affecting the performance of public hospitals in South Korea. Methods : We collected management performance data from 2013 to 2015 from income statements, balance sheets, and annual reports from 32 local public hospitals. The dependent variable used was profitability, which included operating margin, return on assets and net profit to gross revenues. The independent variables were general characteristics, liquidity, stability, and activity. Results : Patient revenues, total assets, and total capital had increased steadily but patient expenses had increased to a greater extent. Operating profit, and net profit were consistently in deficits and the management status of local public hospitals had recently been in difficulty. The debt ratio, quick ratio, ratio of fixed liability and fixed assets turnover rate have a significant positive(+) effect on performance in the years 2013-2015. Conclusions : We suggest management strategies for these hospitals based on the results analyzed.

최근 10년간 대학병원 경영성과 비교분석 (A Comparative Analysis of Business Performance of University Hospitals for the Past 10 Years)

  • 양종현
    • 보건의료산업학회지
    • /
    • 제10권3호
    • /
    • pp.13-25
    • /
    • 2016
  • Objectives : The purposes of this study was to analyze business performance of university hospitals for the past 10 years. Methods : Management and finance data from 2005 to 2014 were collected from balance sheets, income statements and annual reports from 27 university hospitals. The dependant variable used was profitability which included return on assets, operating margin and net profit to gross revenues 1. The independent variables were general characteristics, liquidity, stability, activity and financial ratios. Results : University hospitals over the last 10 years had achieved good management performance. Using financial leverage, patient revenues, operating profit, nonpatient revenues, total assets and total debt, the total amount had increased by more than double. The ratio of fixed liability and fixed assets turnover was found to have a significant positive (+) effect on management performance in the years 2012-2014. Conclusions : Based on these results, this study suggests a more in-depth analysis using fixed liabilities and fixed assets.