• Title/Summary/Keyword: On-current

Search Result 53,455, Processing Time 0.077 seconds

Study on Extractable power capacity of Tidal current power farm in the Feasibility investigation (해양 조류발전단지 타당성 조사시 발전용량 산출방법에 관한 연구)

  • Jo, Chulhee;Kim, Doyoub;Chae, Kwangsu;Yim, Jinyoung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.169.1-169.1
    • /
    • 2010
  • Due to global warming, the need to secure an alternative resource has become the international issue. Not like other renewable energy sources, TCP is the high reliable and predictable and continuous energy source as the current pattern and speed can be predicted throughout the year. Having very strong tidal current speeds, there are many suitable site for the application of TCP (Tidal Current Power) on the west and south coastal region in Korea. The maximum current speed in the south is recorded up to 6.5m/s. Due to the high tidal current speed on the west coast of Korea, numerous tidal current projects are being planned. To extract a significant quantity of power, a tidal current farm with number of devices is required in the ocean. However, it is important to estimate the potential quantity of energy in the area. Also the realistic quantity that can be extracted is to be investigated. Based on the estimated energy production considering the number of devices and the interactional effects, system type, the water depth and etc., the cost of the development and the benefit from SMP can be estimated. The feasibility study for the 200MW tidal in Incheon, Korea has been performed recently. Based on the actual feasibility study, the procedure and the key points for the application of tidal current power farm are introduced in the paper.

  • PDF

Analysis on Current Limiting Characteristics of the SFCL with Magnetically Coupled Two Coils and YBCO Coated Conductor Due to the Winding Direction and the Turn Number' Ratio Between Two Coils (직렬 연결된 두 코일과 YBCO Coated Conductor로 구성된 초전도 전류제한기의 권선방향과 권선 비에 따른 전류제한 특성 분석)

  • Lee, Dong-Hyeok;Du, Ho-Ik;Kim, Yong-Jin;Han, Byoung-Sung;Han, Sang-Chul;Lee, Jeong-Phil
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.1
    • /
    • pp.52-56
    • /
    • 2011
  • The ongoing Superconducting Fault Current Limiter(SFCL) development mainly has focused on the application of commercializaton and power system through combining with normal-conducting device, moving away from current-limiting method, which is solely dependant on the existing superconductor. Compared to the structural development above, on the other hand, the research on applying superconducting current-limiting element to SFCL, the heart of SFCL, still has a lot left to do, apart form traditional resistive type SFCL. In this study, we looked into the current limiting characteristic of SFCL using core and coil. YBCO coated conductor with stainless steel stabilizer layer was verified by the excellent of current-limiting element of the resistive type SFCL that has a high Jc and index as well as being superior in mechanical property. Also, we study temperature characteristics and resistance characteristics, max voltage, response time and current-limiting ability that can be an indicator as current-limiting element while applying to superconducting current-limiting element caused by variation of winding direction, winding ratio of SFCL using core and coil.

The Effect of Pulse Plating on the Current Efficiency in Trivalent Chromium Bath (3가크롬 도금욕에서 펄스도금조건이 전류효율에 미치는 영향)

  • 황경진;안종관;이만승;오영주
    • Journal of the Korean institute of surface engineering
    • /
    • v.36 no.2
    • /
    • pp.161-167
    • /
    • 2003
  • In order to investigate the effects of pulse plating conditions on the electrodeposition of trivalent chromium, electroplating experiments from bath with low concentration of trivalent chromium were performed. The variation of current efficiency of chromium electroplating with the electroplating conditions was explained. The maximum current efficiency of pulse plating is 6.4 times as high as that of direct plating at the same mean current density The nodular size increased with pulse plating time and the pulse frequency.

Switching current density for spin transfer torque magnetic random access memory with Dzaloshinskii-Moriya Interaction

  • Song, Kyungmi;Lee, Kyung-Jin
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2015.05a
    • /
    • pp.78-79
    • /
    • 2015
  • We investigate the switching current for various cell diameters and DM interaction. We find that the current density for switching can depend strongly on the cell size when the switching is governed by the domain wall motion. Moreover the switching current density is also strongly influenced by DM interaction. In the presentation, we will discuss the effect of domain wall formation and more various DMI constant on the switching current desity in detail.

  • PDF

Effects of Circulating current on the controlled Circulating current Cycloconverter (순환전류제어형 싸이크로콘버터에서 순환전류의 영향)

  • Go, Seok-Jin;Lee, Kyu-Jong;Seong, Se-Jin
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.140-143
    • /
    • 1988
  • In this study, so called high frequency cycloconverter which converts commercial so power source directly to high frequency power source is proposed. In this system, the circulating current play very important role. Its state and magnitude effects on system characteristics. This paper deals with the control method of the circulating current and side band component analysis of high frequency side current which is produced by it.

  • PDF

A Study on the Current Change in Final Closing Section (최종체절구간에서 유속변화에 관한 연구)

  • 신문섭;유시흥;이용래;권철휘;최용규
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1999.10c
    • /
    • pp.181-184
    • /
    • 1999
  • The purpose of this study is to find on the Current Change and Residual current in Final closing section of Seamangum the sea dike . The M2 current was calculated in two case of the two and three point Final closing section. The residual currents are calculated diagnositically from the observed water temperature and salinity data and wind data and tidal residual current.

  • PDF

Passive Current Sharing Characteristics of Multi-Phase Synchronous Buck Converter (다상 동기 벅 컨버터의 Passive Current Sharing 특성)

  • Kim, Jeong-Hoon;Cho, Kyung-Sig;Chung, Se-Kyo
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.175-177
    • /
    • 2007
  • An analysis on a passive current sharing characteristics of a multi-phase synchronous buck converter is presented. The passive current sharing method is simple but its characteristics depend on the converter equivalent resistance and PWM uniformity. In this paper, the load sharing and power consumption of the passive current sharing system for the converter equivalent resistance and duty ratio inequalities are investigated through the simulation and experiment.

  • PDF

Accuracy Enhancement Technique in the Current-Attenuator Circuit (전류 감쇠 조정 회로에서의 정밀도 향상 기술)

  • Kim, Seong-Kweon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.8
    • /
    • pp.116-121
    • /
    • 2005
  • To realize the tap coefficient of a finite impulse response(FIR) filter or the twiddle factor of a fast Fourier transform(FFT) using a current-mode analog circuit, a high accurate current-attenuator circuit is needed This paper introduces an accuracy enhancement technique in the current-mode signal processing. First of all, the DC of set-current error in a conventional current-attenuator using a gate-ratioed orient mirror circuit is analyzed and then, the current-attenuator circuit with a negligibly small DC offset-current error is introduced. The circuit consists of N-output current mirrors connected in parallel with me another. The output current of the circuit is attenuated to 1/N of the input current. On the basis of the Kirchhoff current law, the current scale ratio is determined simply by the number of the current mirrors in the N-current mirrors connected in parallel. In the proposed current-attenuator circuit the scale accuracy is limited by the ac gain error of the current mirror. Considering that a current mirror has a negligibly small ac gain error, the attainable maximum scale accuracy is theoretically -80[dB] to the input current.

Analysis and Understanding of Eddy Current Problem using electromagnetic field Packeg (전자장 해석 프로그램을 이용한 와전류 문제의 해석 및 이해)

  • Lim, Keon-Gyu;Lee, Hyang-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.2203-2204
    • /
    • 2006
  • When the coil with alternating current approaches to the conductor the eddy current flows in conductor. Eddy current is concentrated on the conductor surface and decrescent because of skin effet.. In this paper investigated eddy current characteristic that is happened in conductor. Analyzed characteristic using electromagnetic field finite element analysis program that is commercialized to analyze value of eddy current and penetration depth. Analyzed creation value of eddy current and penetration depth in conductor that change operation frequency and the material of conductor, coil outside diameter, inside diameter, position, type of conductor from analyzed eddy current characteristic. The results. using distribution of eddy current and penetration depth data is that will help to forecast ECT(Eddy Current Testing), Eddy current application and use field, eddy current loss.

  • PDF

Analysis and Understanding of Eddy Current Problem using electromagnetic field Packeg (전자장 해석 프로그램을 이용한 와전류 문제의 해석 및 이해)

  • Lim, Keon-Gyu;Lee, Hyang-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.571-572
    • /
    • 2006
  • When the coil with alternating current approaches to the conductor the eddy current flows in conductor. Eddy current is concentrated on the conductor surface and decrescent because of skin effet.. In this paper investigated eddy current characteristic that is happened in conductor. Analyzed characteristic using electromagnetic field finite element analysis program that is commercialized to analyze value of eddy current and penetration depth. Analyzed creation value of eddy current and penetration depth in conductor that change operation frequency and the material of conductor, coil outside diameter, inside diameter, position, type of conductor from analyzed eddy current characteristic. The results, using distribution of eddy current and penetration depth data is that will help to forecast ECT(Eddy Current Testing), Eddy current application and use field, eddy current loss.

  • PDF