• Title/Summary/Keyword: Nuclear medicine image

Search Result 615, Processing Time 0.038 seconds

Increase of Tc-99m RBC SPECT Sensitivity for Small Liver Hemangioma using Ordered Subset Expectation Maximization Technique (Tc-99m RBC SPECT에서 Ordered Subset Expectation Maximization 기법을 이용한 작은 간 혈관종 진단 예민도의 향상)

  • Jeon, Tae-Joo;Bong, Jung-Kyun;Kim, Hee-Joung;Kim, Myung-Jin;Lee, Jong-Doo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.6
    • /
    • pp.344-356
    • /
    • 2002
  • Purpose: RBC blood pool SPECT has been used to diagnose focal liver lesion such as hemangioma owing to its high specificity. However, low spatial resolution is a major limitation of this modality. Recently, ordered subset expectation maximization (OSEM) has been introduced to obtain tomographic images for clinical application. We compared this new modified iterative reconstruction method, OSEM with conventional filtered back projection (FBP) in imaging of liver hemangioma. Materials and Methods: Sixty four projection data were acquired using dual head gamma camera in 28 lesions of 24 patients with cavernous hemangioma of liver and these raw data were transferred to LINUX based personal computer. After the replacement of header file as interfile, OSEM was performed under various conditions of subsets (1,2,4,8,16, and 32) and iteration numbers (1,2,4,8, and 16) to obtain the best setting for liver imaging. The best condition for imaging in our investigation was considered to be 4 iterations and 16 subsets. After then, all the images were processed by both FBP and OSEM. Three experts reviewed these images without any information. Results: According to blind review of 28 lesions, OSEM images revealed at least same or better image quality than those of FBP in nearly all cases. Although there showed no significant difference in detection of large lesions more than 3 cm, 5 lesions with 1.5 to 3 cm in diameter were detected by OSEM only. However, both techniques failed to depict 4 cases of small lesions less than 1.5 cm. Conclusion: OSEM revealed better contrast and define in depiction of liver hemangioma as well as higher sensitivity in detection of small lesions. Furthermore this reconstruction method dose not require high performance computer system or long reconstruction time, therefore OSEM is supposed to be good method that can be applied to RBC blood pool SPECT for the diagnosis of liver hemangioma.

A Study on GPU-based Iterative ML-EM Reconstruction Algorithm for Emission Computed Tomographic Imaging Systems (방출단층촬영 시스템을 위한 GPU 기반 반복적 기댓값 최대화 재구성 알고리즘 연구)

  • Ha, Woo-Seok;Kim, Soo-Mee;Park, Min-Jae;Lee, Dong-Soo;Lee, Jae-Sung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.5
    • /
    • pp.459-467
    • /
    • 2009
  • Purpose: The maximum likelihood-expectation maximization (ML-EM) is the statistical reconstruction algorithm derived from probabilistic model of the emission and detection processes. Although the ML-EM has many advantages in accuracy and utility, the use of the ML-EM is limited due to the computational burden of iterating processing on a CPU (central processing unit). In this study, we developed a parallel computing technique on GPU (graphic processing unit) for ML-EM algorithm. Materials and Methods: Using Geforce 9800 GTX+ graphic card and CUDA (compute unified device architecture) the projection and backprojection in ML-EM algorithm were parallelized by NVIDIA's technology. The time delay on computations for projection, errors between measured and estimated data and backprojection in an iteration were measured. Total time included the latency in data transmission between RAM and GPU memory. Results: The total computation time of the CPU- and GPU-based ML-EM with 32 iterations were 3.83 and 0.26 see, respectively. In this case, the computing speed was improved about 15 times on GPU. When the number of iterations increased into 1024, the CPU- and GPU-based computing took totally 18 min and 8 see, respectively. The improvement was about 135 times and was caused by delay on CPU-based computing after certain iterations. On the other hand, the GPU-based computation provided very small variation on time delay per iteration due to use of shared memory. Conclusion: The GPU-based parallel computation for ML-EM improved significantly the computing speed and stability. The developed GPU-based ML-EM algorithm could be easily modified for some other imaging geometries.

A Study of Influence of Filgrastim on PET/CT In Diffuse Large B cell Lymphoma (미만성 거대 B 세포 림프종 환자에서 Filgrastim 사용이 PET/CT 영상에 미치는 영향에 대한 고찰)

  • NamKoong, Hyuk;Park, Hoon-Hee;Ban, Yung-Gak;Kang, Sin-Chang;Kim, Sang-Kyoo;Lim, Han-Sang;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.17-23
    • /
    • 2009
  • Purpose: It has been known that PET/CT is very valuable in follow-up study of diffuse large B cell lymphoma (DLBCL). Generally, in DLBCL, radiotherapy and chemotherapy has been progressed, because the lesion hasn‘t been limited to one site. And, it has lead to the decrease of leukocyte like neutropenia, due to myelosuppression of chemotherapy. So, in that case, administration of Filgrastim (Granulocyte colony-stimulating factor; G-CSF) is universal. However, in short time after administration, PET/CT has limitation to offer accurate images, through the uptake of $^{18}F$-FDG is increased in the region that is activated bone marrow by hematopoietic growth. Therefore, the aim of this study is that PET/CT in a certain period of time after administration of Filgrastim is able to show normal degree of $^{18}F$-FDG uptake. Materials and Methods: 10 patients under follow-up study of diffuse large B cell lymphoma were examined in this study from January, 2007 to January, 2009 (Male: 4 persons; Female: 6 persons; The mean age: 53.8 years old; The mean weight: 57.3 Kg). Using PET/CT (Discovery STe; GE Healthcare, Milwaukee, WI, USA), whole body images were acquired in 1 hour after $^{18}F$-FDG injection. For image analysis, each ROI ($120\;mm^2$) was drawn on $C^6$ (the sixth C-spine), $L_4$ (the forth L-spine), liver, spleen, and lung, then SUV (Standard Uptake Value)s were measured. We compared with each uptake between in 1-day and 5~7 days after administration of Filgrastim at same patient, so confirmed significance about these by SPSS version 12. Results: In case of $C_6$, $L_4$, spleen, every SUV of 1 day later was remarkably higher than that of 5~7 days later, but liver and lung were similar. Also, the images acquired after 5~7 days distinct remarkably and show normal degree of $^{18}F$-FDG uptake, because uptake of bone was almost disappeared. Conclusions: In this study, each SUV was prominent difference as a period of time after Filgrastim’s administration. And Filgrastim makes concentrate uptake of $^{18}F$-FDG in bone, but, after 5~7 days, bone‘s uptake was greatly decreased. Therefore, we are able to infer a certain period of time that shows normal degree of uptake, by numerical value proven. Also, we consider that this study contribute to advanced study about the other agent like Pegfilgrastim, Lenograstim besides Filgrastim, afterwards.

  • PDF

A Refined Method for Quantification of Myocardial Blood Flow using N-13 Ammonia and Dynamic PET (N-13 암모니아와 양전자방출단층촬영 동적영상을 이용하여 심근혈류량을 정량화하는 새로운 방법 개발에 관한 연구)

  • Kim, Joon-Young;Lee, Kyung-Han;Kim, Sang-Eun;Choe, Yearn-Seong;Ju, Hee-Kyung;Kim, Yong-Jin;Kim, Byung-Tae;Choi, Yong
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.1
    • /
    • pp.73-82
    • /
    • 1997
  • Regional myocardial blood flow (rMBF) can be noninvasively quantified using N-13 ammonia and dynamic positron emission tomography (PET). The quantitative accuracy of the rMBF values, however, is affected by the distortion of myocardial PET images caused by finite PET image resolution and cardiac motion. Although different methods have been developed to correct the distortion typically classified as partial volume effect and spillover, the methods are too complex to employ in a routine clinical environment. We have developed a refined method incorporating a geometric model of the volume representation of a region-of-interest (ROI) into the two-compartment N-13 ammonia model. In the refined model, partial volume effect and spillover are conveniently corrected by an additional parameter in the mathematical model. To examine the accuracy of this approach, studies were performed in 9 coronary artery disease patients. Dynamic transaxial images (16 frames) were acquired with a GE $Advance^{TM}$ PET scanner simultaneous with intravenous injection of 20 mCi N-13 ammonia. rMBF was examined at rest and during pharmacologically (dipyridamole) induced coronary hyperemia. Three sectorial myocardium (septum, anterior wall and lateral wall) and blood pool time-activity curves were generated using dynamic images from manually drawn ROIs. The accuracy of rMBF values estimated by the refined method was examined by comparing to the values estimated using the conventional two-compartment model without partial volume effect correction rMBF values obtained by the refined method linearly correlated with rMBF values obtained by the conventional method (108 myocardial segments, correlation coefficient (r)=0.88). Additionally, underestimated rMBF values by the conventional method due to partial volume effect were corrected by theoretically predicted amount in the refined method (slope(m)=1.57). Spillover fraction estimated by the two methods agreed well (r=1.00, m=0.98). In conclusion, accurate rMBF values can be efficiently quantified by the refined method incorporating myocardium geometric information into the two-compartment model using N-13 ammonia and PET.

  • PDF

Research on The Utility of Acquisition of Oblique Views of Bilateral Orbit During the Dacryoscintigraphy (눈물길 조영검사 시 양측 안 와 사위 상 획득의 유용성에 대한 연구)

  • Park, Jwa-Woo;Lee, Bum-Hee;Park, Seung-Hwan;Park, Su-Young;Jung, Chan-Wook;Ryu, Hyung-Gi;Kim, Ho-Shin
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.76-81
    • /
    • 2014
  • Purpose: Diversity and the lachrymal duct deformities and the passage inside the nasal cavity except for anterior image such as epiphora happens during the test were able to express more precisely during the dacryoscintigraphy. Also, we thought about the necessity of a method to classify the passage into the naso-lachrymal duct from epiphora. Therefore, we are to find the validity of the method to obtain both oblique views except for anterior views. Materials and Methods: The targets of this research are 78 patients with epiphora due to the blockage at the lachrymal duct from January 2013 to August 2013. Average age was $56.96{\pm}13.36$. By using a micropipette, we dropped 1-2 drops of $^{99m}TcO4^-$ of 3.7 MBq (0.1 mCi) with $10{\mu}L$ of each drop into the inferior conjunctival fold, then we performed dynamic check for 20 minutes with 20 frames of each minute. In case of we checked the passage from both eyes to nasal cavity immediately after the dynamic check, we obtained oblique view immediately. If we didn't see the passage in either side of the orbit, we obtained oblique views of the orbit after checking the frontal film in 40 minutes. The instrument we used was Pin-hole Collimator with Gamma Camera(Siemens Orbiter, Hoffman Estates, IL, USA). Results: Among the 78 patients with dacryoscintigraphy, 35 patients were confirmed with passage into the nasal cavity from the anterior view. Among those 35 patients, 15 patients were confirmed with passage into the nasal cavity on both eyes, and it was able to observe better passage patterns through oblique view with a result of 8 on both eyes, 2 on left eye, and 1 on right eye. 20 patients had passage in left eye or right eye, among those patients 10 patients showed clear passage compared to the anterior view. 13 patients had possible passage, and 30 patients had no proof of motion of the tracer. To sum up, 21 patients (60%) among 35 patients showed clear pattern of passage with additional oblique views compared to anterior view. People responded obtaining oblique views though 5 points scale about the utility of passage identification helps make diagnoses the passage, passage delayed, and blockage of naso-lachrymal duct by showing the well-seen portions from anterior view. Also, when classifying passage to naso-lachrymal duct and flow to the skin, oblique views has higher chance of classification in case of epiphora (anterior:$4.14{\pm}0.3$, oblique:$4.55{\pm}0.4$). Conclusion: It is considered that if you obtain oblique views of the bilateral orbits in addition to anterior view during the dacryoscintigraphy, the ability of diagnose for reading will become higher because you will be able to see the areas that you could not observe from the anterior view so that you can see if it emitted after the naso-lachrymal duct and the flow of epiphora on the skin.

  • PDF

Comparison of Activity Capacity Change and GFR Value Change According to Matrix Size during 99mTc-DTPA Renal Dynamic Scan (99mTc-DTPA 신장 동적 검사(Renal Dynamic Scan) 시 동위원소 용량 변화와 Matrix Size 변경에 따른 사구체 여과율(Glomerular Filtration Rate, GFR) 수치 변화 비교)

  • Kim, Hyeon;Do, Yong-Ho;Kim, Jae-Il;Choi, Hyeon-Jun;Woo, Jae-Ryong;Bak, Chan-Rok;Ha, Tae-Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.24 no.1
    • /
    • pp.27-32
    • /
    • 2020
  • Purpose Glomerular Filtration Rate(GFR) is an important indicator for evaluating renal function and monitoring the progress of renal disease. Currently, the method of measuring GFR in clinical trials by using serum creatinine value and 99mTc-DTPA(diethylenetriamine pentaacetic acid) renal dynamic scan is still useful. After the Gates method of formula was announced, when 99mTc-DTPA Renal dynamic scan is taken, it is applied the GFR is measured using a gamma camera. The purpose of this paper is to measure the GFR by applying the Gates method of formula. It is according to effect activity and matrix size that is related in the GFR. Materials and Methods Data from 5 adult patients (patient age = 62 ± 5, 3 males, 2 females) who had been examined 99mTc-DTPA Renal dynamic scan were analyzed. A dynamic image was obtained for 21 minutes after instantaneous injection of 99mTc-DTPA 15 mCi into the patient's vein. To evaluate the glomerular filtration rate according to changes in activity and matrix size, total counts were measured after setting regions of interest in both kidneys and tissues in 2-3 minutes. The distance from detector to the table was maintained at 30cm, and the capacity of the pre-syringe (PR) was set to 15, 20, 25, 30 mCi, and each the capacity of post-syringe (PO) was 1, 5, 10, 15 mCi is set to evaluate the activity change. And then, each matrix size was changed to 32 × 32, 64 × 64, 128 × 128, 256 × 256, 512 × 512, and 1024 × 1024 to compare and to evaluate the values. Results As the activity increased in matrix size, the difference in GFR gradually decreased from 52.95% at the maximum to 16.67% at the minimum. The GFR value according to the change of matrix size was similar to 2.4%, 0.2%, 0.2% of difference when changing from 128 to 256, 256 to 512, and 512 to 1024, but 54.3% of difference when changing from 32 to 64 and 39.43% of difference when changing from 64 to 128. Finally, based on the presently used protocol, 256 × 256, PR 15 mCi and PO 1 mCi, the GFR value was the largest difference with 82% in PR 15 mCi and PO 1 mCi. conditions, and at the least difference is 0.2% in the conditions of PR 30 mCi and PO 15 mCi. Conclusion Through this paper, it was confirmed that when measuring the GFR using the gate method in the 99mTc-DTPA renal dynamic scan. The GFR was affected by activity and matrix size changes. Therefore, it is considered that when taking the 99mTc-DTPA renal dynamic scan, is should be careful by applying appropriate parameters when calculating GFR in the every hospital.

Implementation of a Coded Aperture Imaging System for Gamma Measurement and Experimental Feasibility Tests

  • Kim, Kwangdon;Lee, Hakjae;Jang, Jinwook;Chung, Yonghyun;Lee, Donghoon;Park, Chanwoo;Joung, Jinhun;Kim, Yongkwon;Lee, Kisung
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.6 no.1
    • /
    • pp.66-70
    • /
    • 2017
  • Radioactive materials are used in medicine, non-destructive testing, and nuclear plants. Source localization is especially important during nuclear decommissioning and decontamination because the actual location of the radioactive source within nuclear waste is often unknown. The coded-aperture imaging technique started with space exploration and moved into X-ray and gamma ray imaging, which have imaging process characteristics similar to each other. In this study, we simulated $21{\times}21$ and $37{\times}37$ coded aperture collimators based on a modified uniformly redundant array (MURA) pattern to make a gamma imaging system that can localize a gamma-ray source. We designed a $21{\times}21$ coded aperture collimator that matches our gamma imaging detector and did feasibility experiments with the coded aperture imaging system. We evaluated the performance of each collimator, from 2 mm to 10 mm thicknesses (at 2 mm intervals) using root mean square error (RMSE) and sensitivity in a simulation. In experimental results, the full width half maximum (FWHM) of the point source was $5.09^{\circ}$ at the center and $4.82^{\circ}$ at the location of the source was $9^{\circ}$. We will continue to improve the decoding algorithm and optimize the collimator for high-energy gamma rays emitted from a nuclear power plant.

Phantom Image Evaluations Depending on the Quality Control-Uniformity of Brain Perfusion SPECT Scanner (뇌 관류 SPECT 스캐너의 정도관리-균일도에 따른 팬텀 영상 평가)

  • Jung-Soo, Kim;Hyun-Jin, Yang;Joon, Kim;Chan-Rok, Park
    • Journal of radiological science and technology
    • /
    • v.46 no.1
    • /
    • pp.29-36
    • /
    • 2023
  • To have highly reliable diagnostic performance of it, this study comparatively analyzed spatial resolution of SPECT images and interrelationship depending on the changes of system uniformity of ga㎜a camera through phantom analysis. This study chose 6 kinds of results from quality control (uniformity) of triple head SPECT scanner operated in an university hospital in Seoul for six months. Then, study measured spatial resolutions (FWHM) of the images restructured by injecting radiopharmaceuticals to Jaszczak phantom, and doing SPECT scanning under the same conditions as clinical ones using the analytical program (image J). Quality controls performed by the experimental institution showed that differential uniformity of UFOV ranged from 2.76% to 7.61% (4.46±2.07), and integral uniformity of UFOV ranged from 1.98% to 5.42% (3.01±1.43). Meanwhile, Quantitative analysis evaluations of phantom images depending on the changes of uniformity of SPECT scanner detector showed that as the uniformity values of UFOV and CFOV decreased, FWHM values of phantom images decreased from 8.5 ㎜ to 5.8 ㎜. That is, it was quantitatively identified that the higher uniformity of detector is, the better spatial resolution of images gets (P<0.05). It is very important to perform continuous and consistent quality control of the nuclear medicinal system, and users should be clearly conscious of it.

Hybrid model-based and deep learning-based metal artifact reduction method in dental cone-beam computed tomography

  • Jin Hur;Yeong-Gil Shin;Ho Lee
    • Nuclear Engineering and Technology
    • /
    • v.55 no.8
    • /
    • pp.2854-2863
    • /
    • 2023
  • Objective: To present a hybrid approach that incorporates a constrained beam-hardening estimator (CBHE) and deep learning (DL)-based post-refinement for metal artifact reduction in dental cone-beam computed tomography (CBCT). Methods: Constrained beam-hardening estimator (CBHE) is derived from a polychromatic X-ray attenuation model with respect to X-ray transmission length, which calculates associated parameters numerically. Deep-learning-based post-refinement with an artifact disentanglement network (ADN) is performed to mitigate the remaining dark shading regions around a metal. Artifact disentanglement network (ADN) supports an unsupervised learning approach, in which no paired CBCT images are required. The network consists of an encoder that separates artifacts and content and a decoder for the content. Additionally, ADN with data normalization replaces metal regions with values from bone or soft tissue regions. Finally, the metal regions obtained from the CBHE are blended into reconstructed images. The proposed approach is systematically assessed using a dental phantom with two types of metal objects for qualitative and quantitative comparisons. Results: The proposed hybrid scheme provides improved image quality in areas surrounding the metal while preserving native structures. Conclusion: This study may significantly improve the detection of areas of interest in many dentomaxillofacial applications.

Imaging of Tumor Proliferation Using Iodine-131-Iodomethyluridine (Iodine-131-Iodomethyluridine을 이용한 종양세포증식의 영상화에 관한 실험적 연구)

  • Min Kyung-Yoon;Kim, Chang-Guhn;Kim, Hyun-Jeong;Lim, Hyung-Guhn;Rho, Ji-Young;Juhng Seon-Kwan;Won Jong-Jin;Yang, David J.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.3
    • /
    • pp.344-350
    • /
    • 1996
  • Purpose : Noninvasive imaging of tumor cell proliferation could be helpful in the evaluation of tumor growth potential and could provide an early assessment of treatment response. Radiolabeled thymidine, uridine and adenosine have been used to evaluate tumor cell proliferation. These nucleoside analogs are incorporated into DNA during proliferation. Iodine-131-Iodomethyluridine, an analog of Iodine-131-Iododeoxyuridine, is also involved in DNA/RNA synthesis. The purpose of this study was to develop Iodine-131-Iodomethylurdine and image tumor proliferation using Iodine-131-Iodomethyluridine. Materials and Methods : Radiosynthesis of Iodine-131-5-Iodo-2'-O-methyluridine (Iodine-131-Iodomethyluridine) was prepared from 10 mg of 2'-O-methyluridine(Sigma chemical Co., St. Louis, Missouri) and 2.1 mCi(SP. 10Ci/mg) of Iodine-131-labeled sodium iodide in $100{\mu}l$ of water using iodogen reaction. Female Fischer 344 rats were inoculated in the thigh area with breast tumor cells(13765 NF, $10^5$ cells/rat S.C.). After 14 days, the Iodine-131-Iodomethyluridine $10{\mu}Ci$ was injected to three groups of rats(3/group). The percent of injected dose per gram of tissue weight was determined at 0.5-hours, 2-hours, 4-hours, and 24-hours respectively. Tumor bearing rats after receiving Iodine-131-Iodomethyluridine($50{\mu}Ci$ IV) were euthanized at 2 hours after injection. Autoradiography was done using freeze-dried $50{\mu}m$ coronal section. After injection of Iodine-131- Iodomethyluridine ($10{\mu}Ci$/rat, IV) in three breast tumor-bearing rats, planar scintigraphy was taken at 45 minutes, 90 minutes and 24 hours. Results : Iodine-131-Iodomethyluridine was conveniently synthesized using iodogen reaction. The biodistribution showed fast blood clearance and the tumor-to-tissue uptake ratios showed that optimal imaging time was at 2 hours postinjection. Autoradiogram and planar scintigram indicated that tumor could be well visualized. Conclusion : The findings suggest that Iodine-131-Iodomethyluridine, a new radio-iodinated nucleoside, has potential use for evaluation of active regions of tumor growth.

  • PDF