Characteristics Evaluation of the Lens for Underwater Acoustic Imaging (수중음향 영상화를 위한 렌즈 제작 및 특성 평가)

  • Cho, Wan-Ho;Kwon, Hyu-Sang;Cho, Yo-Han;Seo, Hee-Seon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.6_spc
    • /
    • pp.687-696
    • /
    • 2016
  • A series of process to design an acoustic lens for underwater imaging is reviewed and the method to evaluate characteristics of the lens is investigated. If the target specification of lens is given, the design process consists of the material selection, evaluation of its properties, lens geometry design, prediction of lens characteristics, manufacturing, and evaluation by measurement. In this study, an actual acoustical lens is made by cutting polymethylpentene block. The characteristics of lens are predicted by the hybrid method, combination of ray tracing and Rayleigh integral. For the direct comparison between the prediction and measurement results, a simulation method based on the equivalent source method is suggested to reflect the actual radiation pattern of transducer used for measurements. Finally, the measurement is conducted in a small water tank to observe the actual characteristics of the manufactured lens.

Analysis of Image Quality According to Imaging Parameters in Digital Tomosynthesis (디지털 단층영상합성장치의 영상획득 조건에 따른 화질 분석)

  • Lee, Dahye;Lee, Seungwan;Kim, Burnyoung;Yim, Dobin;Nam, Kibok;Cho, Jeonghyo
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.477-486
    • /
    • 2020
  • The purpose of this study was to evaluate the effects of reconstruction filters, X-ray source trajectories and intervals in the quality of digital tomosynthesis (DT) images, and the results was clinically validated. The filtered back-projection was implemented by using Ramp, Shepp-Logan, Cosine, Hamming, Hann and Blackman filters, and the X-ray source trajectories were simulated with 1 × 36, 2 × 18, 3 × 12, 4 × 9 and 6 × 6 arrays. The X-ray source intervals were 5, 10, 20, 30 and 40 mm. The depth resolution, spatial resolution and noise of DT image were evaluated by measuring artifact spread function (ASF), full width at half maximum (FWHM) and signal-to-noise ratio (SNR), respectively. The results showed that the spatial resolution and noise properties of DT images were maximized by the Ramp and Blackman filters, respectively, and the depth resolution and noise properties of the DT images obtained with a 1 × 36 X-ray source trajectory were superior to the other trajectories. The depth resolution and noise properties of DT images improved with an increase of X-ray source intervals, and the high X-ray source intervals degraded the spatial resolution of DT images. Therefore, the characteristics of DT images are highly dependent on reconstruction filters, X-ray source trajectories and intervals, and it is necessary to use optimal imaging parameters in accordance with diagnostic purpose.

Microphone Array Eesign and its Performance for Noise Source Imaging (소음원 영상화를 위한 마이크로폰 배열설계 및 모의 성능 실험)

  • ;Glegg, S. A. L.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1996.10a
    • /
    • pp.130-134
    • /
    • 1996
  • 본 논문에서는 광대역 소음원의 위치를 탐지하여 2차원 영상면에 소음원을 영상화할 수 있는 3차원 마이크로폰 배열을 제안하였다. 배열요소간의 상호상관함수가 2차원 영상면의 화소의 밝기에 대응되도록 영상함수를 유도하였으며 영상면은 사각면 및 원통면등으로 선택 가능 하도록 하여 소음원의 위치동정 해석이 용이하도록 하였다. 몇가지 소음원에 대한 수치 모의 실험결과는 제안된 배열이 소음제어 분야 등에 응용 될 수 있음을 보인다.

  • PDF

Effects of Gradient Switching Noise on ECD Source Localization with the EEG Data Simultaneously Recorded with MRI (MRI와 동시에 측정한 뇌전도 신호로 전류원 국지화를 할 때 경사자계 유발 잡음의 영향 분석)

  • Lee H. R.;Han J. Y.;Cho M. H.;Im C. H.;Jung H. K.;Lee S. Y.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.7 no.2
    • /
    • pp.108-115
    • /
    • 2003
  • Purpose : To evaluate the effect of the gradient switching noise on the ECD source localization with the EEG data recorded during the MRI scan. Materials and Methods : We have fabricated a spherical EEG phantom that emulates a human head on which multiple electrodes are attached. Inside the phantom, electric current dipole(ECD) sources are located to evaluate the source localization error. The EEG phantom was placed in the center of the whole-body 3.0 Tesla MRI magnet, and a sinusoidal current was fed to the ECD sources. With an MRI-compatible EEG measurement system, we recorded the multi channel electric potential signals during gradient echo single-shot EPI scans. To evaluate the effect of the gradient switching noise on the ECD source localization, we controlled the gradient noise level by changing the FOV of the EPI scan. With the measured potential signals, we have performed the ECD source localization. Results : The source localization error depends on the gradient switching noise level and the ECD source position. The gradient switching noise has much bigger negative effects on the source localization than the Gaussian noise. We have found that the ECD source localization works reasonably when the gradient switching noise power is smaller than $10\%$ of the EEG signal power. Conclusion : We think that the results of the present study can be used as a guideline to determine the degree of gradient switching noise suppression in EEG when the EEG data are to be used to enhance the performance of fMRI.

  • PDF

MCNP-polimi simulation for the compressed-sensing based reconstruction in a coded-aperture imaging CAI extended to partially-coded field-of-view

  • Jeong, Manhee;Kim, Geehyun
    • Nuclear Engineering and Technology
    • /
    • v.53 no.1
    • /
    • pp.199-207
    • /
    • 2021
  • This paper deals with accurate image reconstruction of gamma camera using a coded-aperture mask based on pixel-type CsI(Tl) scintillator coupled with silicon photomultipliers (SiPMs) array. Coded-aperture imaging (CAI) system typically has a smaller effective viewing angle than Compton camera. Thus, if the position of the gamma source to be searched is out of the fully-coded field-of-view (FCFOV) region of the CAI system, artifacts can be generated when the image is reconstructed by using the conventional cross-correlation (CC) method. In this work, we propose an effective method for more accurate reconstruction in CAI considering the source distribution of partially-coded field-of-view (PCFOV) in the reconstruction in attempt to overcome this drawback. We employed an iterative algorithm based on compressed-sensing (CS) and compared the reconstruction quality with that of the CC algorithm. Both algorithms were implemented and performed a systematic Monte Carlo simulation to demonstrate the possiblilty of the proposed method. The reconstructed image qualities were quantitatively evaluated in sense of the root mean square error (RMSE) and the peak signal-to-noise ratio (PSNR). Our simulation results indicate that the proposed method provides more accurate location information of the simulated gamma source than the CC-based method.

Similarity analysis of pixelated CdTe semiconductor gamma camera image using a quadrant bar phantom for nuclear medicine: Monte Carlo simulation study

  • Park, Chan Rok;Kang, Seong-Hyeon;Lee, Youngjin
    • Nuclear Engineering and Technology
    • /
    • v.53 no.6
    • /
    • pp.1947-1954
    • /
    • 2021
  • In the nuclear medicine imaging, quality control (QC) process using quadrant bar phantom is fundamental aspect of evaluating the spatial resolution. In addition, QC process of gamma camera is performed by daily or weekly. Recently, Monte Carlo simulation using the Geant4 application for tomographic emission (GATE) is widely applied in the pre-clinical nuclear medicine field for modeling gamma cameras with pixelated cadmium telluride (CdTe) semiconductor detector. In this study, we modeled a pixelated CdTe semiconductor detector and quadrant bar phantom (0.5, 1.0, 1.5, and 2.0 mm bar thicknesses) using the GATE tool. Similarity analysis based on correlation coefficients and peak signal-to-noise ratios was performed to compare image qualities for various source to collimator distances (0, 2, 4, 6, and 8 cm) and collimator lengths (0.2, 0.4, 0.6, 0.8, and 1.0 cm). To this end, we selected reference images based on collimator length and source to collimator distance settings. The results demonstrate that as the collimator length increases and the source to collimator distance decreases, the similarity to reference images improves. Therefore, our simulation results represent valuable information for the modeling of CdTe-based semiconductor gamma imaging systems and QC phantoms in the field of nuclear medicine.

Improvement of signal and noise performance using single image super-resolution based on deep learning in single photon-emission computed tomography imaging system

  • Kim, Kyuseok;Lee, Youngjin
    • Nuclear Engineering and Technology
    • /
    • v.53 no.7
    • /
    • pp.2341-2347
    • /
    • 2021
  • Because single-photon emission computed tomography (SPECT) is one of the widely used nuclear medicine imaging systems, it is extremely important to acquire high-quality images for diagnosis. In this study, we designed a super-resolution (SR) technique using dense block-based deep convolutional neural network (CNN) and evaluated the algorithm on real SPECT phantom images. To acquire the phantom images, a real SPECT system using a99mTc source and two physical phantoms was used. To confirm the image quality, the noise properties and visual quality metric evaluation parameters were calculated. The results demonstrate that our proposed method delivers a more valid SR improvement by using dense block-based deep CNNs as compared to conventional reconstruction techniques. In particular, when the proposed method was used, the quantitative performance was improved from 1.2 to 5.0 times compared to the result of using the conventional iterative reconstruction. Here, we confirmed the effects on the image quality of the resulting SR image, and our proposed technique was shown to be effective for nuclear medicine imaging.

Study on Smart Cooling Technology by Acoustic Streaming Generated by Ultrasonic Vibration Using 3D PIV (3차원 PIV를 활용한 초음파 진동에 의해 발생된 음향 유동을 이용한 스마트 냉각법 연구)

  • Lee, Dong-Ryul;Loh, Byoung-Gook;Kwon, Ki-Jung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.11
    • /
    • pp.1078-1088
    • /
    • 2010
  • In order to analyze the quantitative characteristics of acoustic streaming, experimental setup of 3-D stereoscopic PIV(particle imaging velocimetry) was designed and quantitative ultrasonic flow fields in the gap between the ultrasonic vibrator and heat source were measured. Utilizing acoustic streaming induced by ultrasonic vibration, surface temperature drop of cooling object was also measured. The study on smart cooling method by acoustic streaming induced by ultrasonic vibration was performed due to the empirical relations of flow pattern, average flow velocity, different gaps, and enhancement on cooling rates in the gap. Average velocity fields and maximum acoustic streaming velocity in the open gap between the stationary cylindrical heat source and ultrasonic vibrator were experimentally measured at no vibration, resonance, and non-resonance. It was clearly observed that the enhancement of cooling rates existed owing to the acoustic air flow in the gap at resonance and non-resonance induced by ultrasonic vibration. The ultrasonic wave propagating into air in the gap creates steady-state secondary eddy called acoustic streaming which enhances heat transfer from the heat source to encompassing air. The intensity of the acoustic streaming induced by ultrasonic vibration experimentally depended upon the gap between the heat source and ultrasonic vibrator. The ultrasonic vibration at resonance caused the increase of the acoustic streaming velocity and convective heat transfer augmentation when the flow fields by 3D stereoscopic PIV and temperature drop of the heat source were measured experimentally. The acoustic streaming velocity of air enhancement on cooling rates in the gap is maximal when the gap agrees with the multiples of half wavelength of the ultrasonic wave, which is specifically 12 mm.

Rapid Cooling Mechanism Utilizing Acoustic Streaming Generated by Ultrasonic Vibrations (초음파 진동에 의해 발생된 음향유동을 활용한 급속냉각 메카니즘)

  • Loh, Byoung-Gook;Kwon, Ki-Jung;Lee, Dong-Ryul
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.10 s.115
    • /
    • pp.1057-1066
    • /
    • 2006
  • Acoustic streaming Induced by longitudinal vibration at 30 kHz is visualized for a test fluid flow between the stationary glass plate and ultrasonic vibrating surface with particle imaging velocimetry (PIV) To measure an increase in the velocity of air flow due to acoustic streaming, the velocity of air flow in a gap between the heat source and ultrasonic vibrator is obtained quantitatively using PIV. The ultrasonic wave propagating into air in the gap generates steady-state secondary vortex called acoustic streaming which enhances convective cooling of the stationary heat source. Heat transfer through air in the gap is represented by experimental convective heat transfer coefficient with respect to the gap. Theoretical analysis shows that gaps for maximum heat transfer enhancement are the multiple of half wavelength. Optimal gaps for the actual design are experimentally found to be half wavelength and one wavelength. A drastic temperature variation exists for the local axial direction of the vibrator according to the measurement of the temperature distribution in the gap. The acoustic streaming velocity of the test fluid in the gap is at maximum when the gap agrees with the multiples of half wavelength of the ultrasonic wave, which are specifically 6 mm and 12 mm.

Studies on the millimeter-wave Passive Imaging System (밀리미터파 수동 이미징 시스템 연구)

  • Jung Min-Kyoo;Chae Yeon-Sik;Kim Soon-Koo;Koji Mizuno;Rhee Jin-Koo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.43 no.5 s.347
    • /
    • pp.182-188
    • /
    • 2006
  • In this study, we have designed the millimeter-wave passive imaging system which records energy that is reflected or emitted from the source and produces image. The lens and front-end of receiver appeared to be important in the system to detect input thermal noise signal. The lens for signal focusing has been designed by optical transfer function. Amplifier of the imaging systemhas been set up with 40dB in maximum gain, 5 dB in maximum noise figure, and 10GHz in bandwidth to enhance sensitivity for thermal noise and to receive it in wide-band width as well. The SBD MSS-20 141B10D diode has been used for the detector circuit to convert amplified millimeter-wave signals to DC output.