• 제목/요약/키워드: New-Ring Test

검색결과 82건 처리시간 0.027초

A NEW SYSTEM OF VISUAL PRESENTATION OF ANALYSIS OF TEST PERFORMANCE: THE 'DOUBLE-RING' DIAGRAM

  • Stefadouros Miltiadis A.
    • 대한예방의학회:학술대회논문집
    • /
    • 대한예방의학회 1994년도 교수 연수회(역학)
    • /
    • pp.142-149
    • /
    • 1994
  • Substitution of graphic representation for extensive lists of numerical statistical data is highly desirable by both editors and readers of medical journals, faced with an exploding abundance of contemporary medical literature. A novel graphic tool. the 'double-ring diagram', is described herein which permits visual representation of information regarding certain statistical variables used to describe the performance of a test or physical sign in the diagnosis of a disease. The diagram is relatively easy to construct on the basis of a number of primary data such as the prevalence and the true positive, true negative. false positive and false negative test results. These values are reflected in the diagram along with the values of other statistical variables derived from them. such as the sensitivity. specificity, predictive values for positive and negative test result. and accuracy. This diagram may be useful in visualizing a test's performance and facilitating visual comparison of performance of two or more tests.

  • PDF

LNG 저장탱크용 벽체 멤브레인 개발 (The Development of Wall Membrane for LNG Storage Tank)

  • 오병택;홍성호;윤인수;김영균;서흥석
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집A
    • /
    • pp.907-912
    • /
    • 2001
  • KOGAS had developed the Ring-knot membrane for LNG storage tank. But we found that some modifications were needed in using the Ring-knot membrane for the commercial LNG storage tanks. So, both analytical and experimental studies have been performed to investigate the strength of the new membrane and the reaction force at the anchor point. Using nonlinear FEM code and experiments, the stress analysis of the new corrugated membrane shapes subject to the cryogenic liquid pressure and thermal loading are performed to ensure the stability and fatigue strength of the new membrane. This paper reports on the results of investigations into this new type of membrane.

  • PDF

골드링을 이용한 완전 밀폐형 어버트먼트 개발 및 성능평가 (Development and Performance Evaluation of a Sealing-Type Abutment Inserted with a Gold Ring)

  • 홍대선;전용재;이현열;이승영
    • 한국기계가공학회지
    • /
    • 제15권2호
    • /
    • pp.97-103
    • /
    • 2016
  • When chewing forces are repetitively applied to a dental implant, gaps are often generated at the interface surfaces between the abutment and the fixture, which results in some deterioration, such as loosening of the fastening screw, dental retraction, and fixture fractures. To cope with such problems, a sealing-type abutment having a number of grooves along the conical-surface circumference was previously developed, and it showed better sealing performance than conventional ones. To enhance the sealing performance, a new model in which a gold ring is inserted into the top groove of the sealing-type abutment is developed in this study. In addition, a manufacturing process is developed, and performance evaluations, such as fatigue and sealing tests, are carried out. The evaluation results show that the gold-ring-inserted sealing abutment yields better performance than conventional ones.

체질 진단을 위한 센서 시스템의 개발 (A Development of Measurement System for Diathesis-Diagnosis)

  • 정용래;김승우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 합동 추계학술대회 논문집 정보 및 제어부문
    • /
    • pp.260-263
    • /
    • 2001
  • This paper is to develop the sensing system for opening-force measurement such as O-Ring muscular meridian. We designed to overcome the functional limit that the conventional force-sensor can measure just the closing-force. Therefore, the new sensor can meet a variety of application as well as O-Ring test. The structure of the new sensor is an actuator-type system using an electromagnet. That is made up of mechanical system, electromagnet, current transformer and computer interface circuit. Driving software and user interface program of the new sensor system also is explained in this paper.

  • PDF

휴대전화 이용자 자아이미지가 벨소리와 통화연결음 선택에 미치는 영향 (Effect of Cellular Phone User's Self Image to select Ring-Tone and Ring-Back-Tone)

  • 양승훈
    • 한국콘텐츠학회논문지
    • /
    • 제12권9호
    • /
    • pp.182-193
    • /
    • 2012
  • 벨소리와 통화연결음 시장의 확대에 주목하여 음원소비가 감상용 음원에서 꾸미기용 음원으로의 활용 확대되는 시점에서 발신자와 수신자가 음원에 대하여 브랜드개성으로 인식하는지, 자아표현이 어떠한 방식으로 이루어 질 것인가에 관한 연구이다. 대학생 196명을 대상으로 본인의 자아이미지와 본인이 선택 혹은 선택 예정인 벨소리와 통화연결음이 일치하는지에 대한 설문조사를 실시하였다. 표본을 대상으로 SPSS 19.0 통계패키지를 사용하여 대응표본 t테스트를 실시한 결과 자아이미지의 요인으로 도출된 내향성, 외향성과 벨소리, 통화연결음의 요인으로 도출된 내향성과 외향성의 관계가 서로 불일치하였다. 즉 내향성을 가진 소비자는 외향적인 음원을, 외향적인 소비자는 내향적인 음원을 선택하고 있었다. 휴대전화 발신자는 벨소리와 통화연결음 등 음원을 선택함에 있어 본인이 아닌 상대방을 염두에 두어 본인의 자아이미지와 상반되는 브랜드개성을 가진 음원을 선택하는 즉 과시적 소비성향을 보여주고 있다.

레이저 자극과 O-Ring 경근 측정시스템에 의한 체질진단의 객관화에 관한 연구 (A Study on Objective Diagnosis of constitutions by Laser Stimulation and O-Ring Measurement Systems of Muscular Meridians)

  • 김양영;김주명;이의원;정동명
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1995년도 춘계학술대회
    • /
    • pp.173-178
    • /
    • 1995
  • This paper relates the occidental constitutional theory to the oriental one, concluding their origins to be similar, and demonstrates a new method of constitutional diagnosis by O-Ring Measurement System Of Muscular Meridians and Laser Constitutional Diagnosis. It establishes Laser Constitutional Diagnosis(L.C.D) using laser beams according to the principles of acupuncture and Sa-Sang constitutional physiology under the effect of spatial morphological energy of geometric isomers. Finally, hypothetical theory of L.C.D. was experimented by the O-Ring Measurement Systems of Muscular Meridians(O-R MSMM). O-R MSMM has been specially devised to improve the manual O-Ring Test prevailing to distinguish energetic response by muscle tonicity. Statistically, it has been proved that the constitutional diagnosis with O-R MSMM was highly effective and objective in the clinical experiences.

  • PDF

Synthesis, Characterization and Antimicrobial Activity of New Thiadiazole Derivatives

  • Mullick, Pooja;Khan, Suroor A.;Verma, Surajpal;Alam, Ozair
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권8호
    • /
    • pp.2345-2350
    • /
    • 2010
  • A series of thiadiazole derivatives were synthesized with differently substituted benzoic acids which were cyclized to give differently substituted thiazolidin-4-one. Elemental analysis, IR, $^1H$ NMR, $^{13}C$ NMR and mass spectral data confirmed the structure of the newly synthesized compounds. The derivatives of these moieties were evaluated for antimicrobial activity. Most of the synthesized compounds showed good antimicrobial activity at 200 and $100\;{\mu}g/mL$. Compounds showed most significant antibacterial activity against gram negative test organism Escherichia coli and most significant antifungal activity against test organisms Aspergillus niger and Candida albicans. It was observed that compounds with $OCH_3$ at 3, 4 position of phenyl ring [5(a-l)] were more potent against microbes as compared to compounds having unsubstituted phenyl ring [4(a-l)].

포항가속기 저장링챔버의 헬륨누설검사 (Helium Leak Test for the PLS Storage Ring Chamber)

  • 최만호;김형종;최우천
    • 비파괴검사학회지
    • /
    • 제13권3호
    • /
    • pp.31-38
    • /
    • 1993
  • 포항가속기 저장링 진공챔버는 진공도가 $10^{-10}Torr$로 유지될 수 있도록 설계되었고, 초고진공에 적합하도록 TIG용접을 하여 헬륨에 대한 누설률이 $1{\times}10^{-10}Torr{\cdot}{\ell}/sec$ 이하의 기밀성이 요구되고 있다. 저장링 진공챔버에 적용된 TIG용접방법과 결함에 대해 논하고 누설검사에 사용된 헬륨누설검사기의 원리 및 검사방법에 대해서 보고하고자 한다.

  • PDF

매입형 센서를 활용한 시멘트 풀의 응결 시간 측정 (Setting Estimation of Cement Paste Using New-type Embedded Sensor)

  • 신경준;이도근;서동완;유철민;임민혁;임성환
    • 한국건설순환자원학회논문집
    • /
    • 제4권4호
    • /
    • pp.483-488
    • /
    • 2016
  • 본 연구에서는 시멘트풀 및 모르타르의 초기재령 변형률 거동을 측정할 수 있는 경제적인 매입형 링센서를 고안하였고, 이를 활용하여 시멘트 풀 및 모르타르의 응결시간을 편리하게 측정할 수 있는 방법을 제안하고자 하였다. W/C가 0.30, 0.35, 0.40, 0.45인 배합들에 대하여 실험 연구를 수행하였다. 기존의 비카침과 관입저항침에 의해 측정된 응결시간과 제안된 방법에 의한 응결시간을 비교하였다. 실험결과에 따르면 개발된 링센서는 초기의 팽창거동이 수축거동으로 변화하는 수축의 시작시점을 정확하게 측정할 수 있었다. 또한, 수축 시작 시점을 응결에 대한 합리적인 기준으로 간주할 수 있었으며, 이는 기존 방법의 초결시간과 유사한 것으로 평가되었다.

Cathode Side Engineering to Raise Holding Voltage of SCR in a 0.5-㎛ 24 V CDMOS Process

  • Wang, Yang;Jin, Xiangliang;Zhou, Acheng;Yang, Liu
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제15권6호
    • /
    • pp.601-607
    • /
    • 2015
  • A set of novel silicon controlled rectifier (SCR) devices' characteristics have been analyzed and verified under the electrostatic discharge (ESD) stress. A ring-shaped diffusion was added to their anode or cathode in order to improve the holding voltage (Vh) of SCR structure by creating new current discharging path and decreasing the emitter injection efficiency (${\gamma}$) of parasitic Bipolar Junction Transistor (BJT). ESD current density distribution imitated by 2-dimensional (2D) TCAD simulation demonstrated that an additional current path exists in the proposed SCR. All the related devices were investigated and characterized based on transmission line pulse (TLP) test system in a standard $0.5-{\mu}m$ 24 V CDMOS process. The proposed SCR devices with ring-shaped anode (RASCR) and ring-shaped cathode (RCSCR) own higher Vh than that of Simple SCR (S_SCR). Especially, the Vh of RCSCR has been raised above 33 V. What's more, their holding current is kept over 800 mA, which makes it possible to design power clamp with SCR structure for on chip ESD protection and keep the protected chip away from latch-up risk.