DOI QR코드

DOI QR Code

Setting Estimation of Cement Paste Using New-type Embedded Sensor

매입형 센서를 활용한 시멘트 풀의 응결 시간 측정

  • Shin, Kyung-Joon (Department of Civil Engineering, Chungnam National University) ;
  • Lee, Do-Keun (Department of Civil Engineering, Chungnam National University) ;
  • Seo, Dong-Wan (Department of Civil Engineering, Chungnam National University) ;
  • Yoo, Chul-Min (Department of Civil Engineering, Chungnam National University) ;
  • Lim, Min-Hyuk (Department of Civil Engineering, Chungnam National University) ;
  • Lim, Sung-Hwan (Department of Civil Engineering, Chungnam National University)
  • Received : 2016.12.05
  • Accepted : 2016.12.22
  • Published : 2016.12.30

Abstract

The present study proposes an economical embedded ring-sensor that can measure a strain behavior of cement paste and mortar in early age. Using the proposed ring-sensor, the experimental method is proposed that can measure the setting time of the cement paste and mortar conveniently. The experimental study has been conducted using the mixtures of which W/C are 0.30, 0.35, 0.40, and 0.45. From the test result, the setting times measured by convectional test methods such as vicat method and penetration resistance method are compared with the setting time proposed by this study. The result reveals that the proposed ring-sensor can effectively measure the early age behavior so that can evaluate the time when the contraction starts. In addition, the contraction starting time can be regarded as a rational setting time, which is similar to the initial setting of convectional test methods.

본 연구에서는 시멘트풀 및 모르타르의 초기재령 변형률 거동을 측정할 수 있는 경제적인 매입형 링센서를 고안하였고, 이를 활용하여 시멘트 풀 및 모르타르의 응결시간을 편리하게 측정할 수 있는 방법을 제안하고자 하였다. W/C가 0.30, 0.35, 0.40, 0.45인 배합들에 대하여 실험 연구를 수행하였다. 기존의 비카침과 관입저항침에 의해 측정된 응결시간과 제안된 방법에 의한 응결시간을 비교하였다. 실험결과에 따르면 개발된 링센서는 초기의 팽창거동이 수축거동으로 변화하는 수축의 시작시점을 정확하게 측정할 수 있었다. 또한, 수축 시작 시점을 응결에 대한 합리적인 기준으로 간주할 수 있었으며, 이는 기존 방법의 초결시간과 유사한 것으로 평가되었다.

Keywords

References

  1. ASTM C1698-09. (2014). Standard Test Method for Autogenous Strain of Cement Paste and Mortar, ASTM International, West Conshohocken, PA.
  2. Kim, C.H. (2001). Chemistry Dictionaries, Sehwa pub.
  3. Kim, J.H., Yim, H.J. (2014). "Ultrasonic wave reflection technique to evaluate the initial setting of cement paste," Korea Institute for Structural Maintenance and Inspection Autumn Conference, Jeju, Korea, 18(2), 252-253.
  4. Kim, S.S., Ryu, J.S., Lee, S.T., Jung, H.S. (2009). Materials for Civil Engineering, Third edition, Gumi Publication, Korea [in Korean].
  5. KS F 2436. (2012). Testing Method for Time of Setting of Concrete Mixtures by Penetration Resistance, Korean Agency for Technology and Standards, Korea.
  6. KS L 5108. (2012). Testing Method for Setting Time of Hydraulic Cement by Vicat Needle, Korean Agency for Technology and Standards, Korea.
  7. KS L 5109. (2012). Testing Method for Mechanical Mixing of Hydraulic Cement Pastes and Mortars of Plastic Consistency, Korean Agency for Technology and Standards, Korea.
  8. Lee, H.K., Lee, K.M. (2002). Setting assessment of high strength concrete using the ultrasonic pulse velocity monitoring, Journal of the Korea Concrete Institute, 14(6), 973-981 [in Korean]. https://doi.org/10.4334/JKCI.2002.14.6.973
  9. Lee, H.K., Lee, K.M., Kim, Y.H., Yim, H.J. (2002). Estimation of setting time and early-age strength of concrete using the ultrasonic pulse velocity, Journal of the Korean Society, 22(3), 292-303 [in Korean].
  10. Lee, S.B., Yang, J.M., Choi, S.H., Kim, S.H., Shin, K.J. (2014). "Measurements of setting time for fiber reinforced mortar," Korean Society of Civil Engineers Annual Convention, Daegu, Korea, 1205-1206 [in Korean].
  11. Mehta, P.K., Monteiro, P.J.M. (2014). Concrete, Microstructure Properties and Materials, Third edition, McGraw-hill, NewYork.