• Title/Summary/Keyword: NPD

Search Result 317, Processing Time 0.03 seconds

Small Molecular Organic Nonvolatile Memory Cells Fabricated with in Situ O2 Plasma Oxidation

  • Seo, Sung-Ho;Nam, Woo-Sik;Park, Jea-Gun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.8 no.1
    • /
    • pp.40-45
    • /
    • 2008
  • We developed small molecular organic nonvolatile $4F^2$ memory cells using metal layer evaporation followed by $O_2$ plasma oxidation. Our memory cells sandwich an upper ${\alpha}$-NPD layer, Al nanocrystals surrounded by $Al_2O_3$, and a bottom ${\alpha}$-NPD layer between top and bottom electrodes. Their nonvolatile memory characteristics are excellent: the $V_{th},\;V_p$ (program), $V_e$ (erase), memory margin ($I_{on}/I_{off}$), data retention time, and erase and program endurance were 2.6 V, 5.3 V, 8.5 V, ${\approx}1.5{\times}10^2,\;1{\times}10^5s$, and $1{\times}10^3$ cycles, respectively. They also demonstrated symmetrical current versus voltage characteristics and a reversible erase and program process, indicating potential for terabit-level nonvolatile memory.

SCREENING OF BENZODIAZEPINES IN URINE BY THE IMMUNOASSAY AND QUANTITATION BY GC-NPD METHOD

  • Park, Jongsei;Park, Jeongeum;Park, Myung-Ja
    • Toxicological Research
    • /
    • v.7 no.1
    • /
    • pp.21-27
    • /
    • 1991
  • We developed a simple method to determine benzodiazepines in biological samples using electron capature detectors and nitrogen-phosphorous detectors. The extraction of 13 benezodiazepines in urine at pH 9.5 with toluene and its analysis in GC/NPD showed the peaks in 9-16 min. In this retention time range, the biological backaground was fairly low and the drugs could be identified in low concentrations. The benzodiazepines in urine samples were screened by the fluorescence polarization immunoassay and positive samples were confirmed by the GC/NPD method.

  • PDF

Applicability of Using GC-PDD (Pulsed Discharge Detector) for Multiresidual Pesticides Analysis

  • Oh, Chang-Hwan
    • Food Science and Biotechnology
    • /
    • v.15 no.6
    • /
    • pp.959-966
    • /
    • 2006
  • The electron-capture detector (ECD) of gas chromatographs (GC) has been used widely in pesticide analysis. However, as ECD relies on radioactive material, it is troublesome to purchase and maintain. Therefore, potent replacements for ECD were investigated. A Pulsed-discharge detector (PDD) for ECD was tested and the analytical results of PDD (ECD mode), ${\mu}ECD$, and nitrogen-phosphorus detector (NPD) were compared for 107 pesticides including organochroline, organophosphorus, pyrethroids etc. The number of pesticides identified at the lowest limit of detection (LOD) was 36, 29, and 2 for PDD, ${\mu}ECD$, and NPD, respectively. The remaining pesticides showed same response to PDD and ${\mu}ECD$. The GC-PDD analysis of pesticides spiked into representative agricultural products (brown rice, spinach, and mandarin oranges) also showed good and/or equivalent recoveries using $GC-{\mu}ECD$.

Multi-Pesticide Residue Method for Organopesticide Analysis (유기농약 분석을 위한 Multi-Pesticide Residue Method)

  • 김우성;이봉헌
    • Journal of Environmental Science International
    • /
    • v.6 no.4
    • /
    • pp.385-389
    • /
    • 1997
  • Pesticide residues were extracted with 70% acetone and transferred to dichloromethane. Extracts were applied to open-column chromatography with florisil and alumina-N. The final extract was analyzed by gas chromatography with electron-capture detector(GC /ECD) and nitrogen-phosphorus detector(GC/NPD). Recoveries of the 17 organochlorine pegticides were ranged from 60.8 to 84.9% and those of 15 organophosphate pesticides, from 70.5% to 100.0%(except phosmet and azlnphos-methyls. The minimum detectable levels of this analytical method were low(0.021-0.058mg/kg).

  • PDF

A comparison of new product success factors across advanced countries: A multi-level approach (선진국 제조기업의 신제품 성공요인에 관한 비교 연구: 다수준 접근 방식)

  • Lee, Youngwoo;Cho, Youngsam
    • Knowledge Management Research
    • /
    • v.21 no.2
    • /
    • pp.59-75
    • /
    • 2020
  • In this paper, we investigate the influence of factors on the firm, industry, and country levels on the new product development performance (NPD) of manufacturing firms in advanced economies. The resource-based view, industrial organization theory and institutional theory have established that firm-, industry- and country-level factors are all relevant for the NPD of firms. However, little is known about the relative importance of factors at the three different levels across countries, as prior studies on firms' NPD have focused on specific countries and levels of analysis. Our analysis of survey data from 1,437 manufacturing firms in nine advanced OECD countries shows that while firm-level factors are generally better predictors of firms' innovativeness than either industry- or country-level factors, the results strongly differ across countries, indicating that the relative importance of antecedents of innovativeness is country-specific rather than universal.

Product Specification Management in Collaborative NPD: An Investigation of Problems and Good Practices in Electronics Industry

  • Lam, Ping-Kit;Chin, Kwai-Sang;Cheung, Wai-Ying
    • International Journal of Quality Innovation
    • /
    • v.7 no.1
    • /
    • pp.35-47
    • /
    • 2006
  • Client-supplier collaboration has been an imperative approach to new product development (NPD), in which a good product specification management system and practice is crucial to the assurance of product quality. This study investigates product specification management in client-supplier collaborative NPD. Based on the interviews and survey study, 12 problems and 13 good practices of product specification management are identified. It also compares the importance and degree of the implementation of the product specification practices in Hong Kong electronics industry. The results suggest that more intensive practices should be implemented for better product specification management.

Synthesis of Hole Transport Materials for Organic Light Emitting Device (유기발광디바이스용 정공수송재료의 합성)

  • Chung, Pyung-Jin;Cho, Min-Ju
    • Korean Journal of Materials Research
    • /
    • v.15 no.7
    • /
    • pp.448-452
    • /
    • 2005
  • This study was based on organic electroluminescence display. Especially, TPD and $\alpha-NPD$ for the hole transport materials were synthesized by Ullmann reaction. This reaction was conducted between 3­methylphenylamine, 1-naphthylamine and 4,4'-diiodobiphenyl in toluene containing CuCl catalyst and KOH base. The structural property of reaction products were analyzed by FT-IR, $^1H-NMR$ spectroscopy, and thermal stability, reactivity and PL property were analyzed by melting point, yield and emission spectrum, respectively. The photoluminescence spectra of a pure TPD and $\alpha-NPD$ were observed at approximately 416nm and 438nm respectively. In this study, it was known that the melting point, yield, PL properties of TPD and $\alpha-NPD$ were changed by substituent group of amines.

Monitoring of Uniconazole by GC-NPD (GC-NPD 동시분석법을 이용한 유니코나졸 잔류실태조사)

  • Kim, Eun-Jeung;Choi, Bu-Chuhl;Choi, Su-Jeong;Hong, Chae-Kyu;Kim, Eun-Hee;Choi, Chae-Man;Seo, Young-Ho;Hwang, Young-Sook;Jang, Mi-Ra;Hwang, In-Sook;Kim, Moo-Sang;Chae, Young-Zoo
    • Korean Journal of Food Science and Technology
    • /
    • v.44 no.3
    • /
    • pp.378-381
    • /
    • 2012
  • The monitoring of the uniconazole residual pesticide for agricultural products was conducted by multiclass pesticide multiresidue methods. Samples were collected from June to November, 2011. Uniconazole pesticide was detected in 49 samples from a total of 3,939 samples. The amount of uniconazole pesticide ranged from 0.09 to 17.89 mg/kg in 49 samples. This method was described for the simultaneous determination of uniconazole by gas chromatography with a nitrogen phosphorus detector (GC-NPD) and mass spectrometry (MS). The limit of detection and quantification were 0.006 and 0.018 mg/kg GC-NPD, respectively. For an evaluation of the GC-NPD method, uniconazole spiked into gyeojachae at a level of 0.5, 5 mg/kg was determined. The recoveries of uniconazole by the GC-NPD method ranged from 83.4 to 101.4%. The results indicate that the method of simultaneous analysis is applicable to uniconazole analysis.

Development of analytical method for Isotianil in agricultural commodities using GC-NPD and GC-MSD (GC-NPD와 GC-MSD를 이용한 농산물 중 Isotianil의 공정분석법 개발)

  • Do, Jung-Ah;Lee, Mi-Young;Kang, Il-Hyun;Kwon, Kisung;Oh, Jae-Ho
    • Analytical Science and Technology
    • /
    • v.25 no.6
    • /
    • pp.364-369
    • /
    • 2012
  • Isotianil is a novel fungicide which induces systemic acquired resistance in plants. It has excellent preventive effects as low dosages against rice blast which is one of the most serious diseases in rice. The Maximum Residue Limit (MRL) of Isotianil in republic of korea was set to 0.1 mg/kg in rice, so it is necessary to determine levels of Isotianil residues in agricultural commodities for controlling food safety. Therefore, The purpose of this study was to develop analytical method for the determination of isotiical residues in agricultural commodities using GC-NPD/MSD. Isotianil was extracted with acetonitrile from apple, chinese cabbage, hulled rice, mandarin, pepper, and soybean. The extract was diluted with saline water, and then dichloromethane partition was followed to recover this fungcide from the aqueous phase. A solid phase extraction with Florisil cartridge was additionally employed for final clean up. Isotianil was analyzed and quantitated by GC-NPD and confirmed by GC-MSD. Average recovery of Isotianil ranged from 70.0 to 103.9% in six representative agricultural commodities with relative standard deviations less than 10%, and limit of quantification (LOQ) was 0.05 mg/kg.

Development of Analytical Method for Fenoxanil in Agricultural Products Using GC-NPD and GC/MS (농산물 중 Fenoxanil 잔류성 시험법 개발)

  • Kim, Gyeong-Ha;Ahn, Kyung-Geun;Kim, Gi-Ppeum;Hwang, Young-Sun;Lee, Young Deuk;Choung, Myoung-Gun
    • The Korean Journal of Pesticide Science
    • /
    • v.19 no.4
    • /
    • pp.345-353
    • /
    • 2015
  • The aim of this study is to develop residue analysis method for fenoxanil, a MBI (melanin biosynthesis inhibitor) propionamide fungicide, had mainly been used to control rice blast, and disease of other crops, fruits, and vegetables by using GLC/NPD and GC/MS. Extraction with acetone and partition with n-hexane/dichloromethane (80/20, v/v) were performed from hulled rice, soybean, Kimchi cabbage, green pepper, and apple, then column clean-up with florisil was applied. Mean recoveries were 82.2%-109.1% with less than 7.2% of coefficients of variation and limit of quantitation was set at the concentration of 0.04 mg/kg from the five agricultural products through the determination by GLC/NPD equipped with DB-5 capillary column and single laboratory validation. As a confirmatory method, GC/MS selected ion monitoring (SIM) was set from m/z 125.0, 188.9, and 293.0. Developed method is expected to apply the single residue analysis of fenoxanil in agricultural products.