• Title/Summary/Keyword: Multi winding transformer

Search Result 38, Processing Time 0.036 seconds

Suppression of Common-Mode Voltage in a Multi-Central Large-Scale PV Generation Systems for Medium-Voltage Grid Connection (중전압 계통 연계를 위한 멀티 센트럴 대용량 태양광 발전 시스템의 공통 모드 전압 억제)

  • Bae, Young-Sang;Kim, Rae-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.1
    • /
    • pp.31-40
    • /
    • 2014
  • This paper describes an optimal configuration for multi-central inverters in a medium-voltage (MV) grid, which is suitable for large-scale photovoltaic (PV) power plants. We theoretically analyze a proposed common-mode equivalent model for problems associated with multi-central transformerless-type three-phase full bridge(3-FB) PV inverters employing two-winding MV transformers. We propose a synchronized PWM control strategy to effectively reduce the common-mode voltages that may simultaneously occur. In addition, we propose that the existing 3-FB topology may also have the configuration of a multi-central inverter with a two-winding MV transformer by making a simple circuit modification. Simulation and experimental results of three 350kW PV inverters in a multi-central configuration verify the effectiveness of the proposed synchronization control strategy. The modified transformerless-type 3-FB topology for a multi-central PV inverter configuration is verified using an experimental prototype of a 100kW PV inverter.

Performance improvement of PV_system's inverter that use transformer tap (변압기 탭을 이용한 태양광인버터의 성능개선)

  • Park Noh-Sik;Park Sung-Jun;Kim Kwang-Heon;Lim Young-Cheol;Kwon Soon-Jae;Kim Cheul-U
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.511-514
    • /
    • 2004
  • Proposed about new inverter that can use in PV system in this paper. Multi_level inverter that used inverter makes use of 4 transformers is basis, primary winding of each transformer voltage as can do step_up or step_down to appropriate voltage space tap lake. Put circuit that tap that turn in transformer connects properly according to inhibit signal that sense change of input voltage (output voltage of solar cell place) and transformer secondary voltage controls point of contact of relay so that get into fixed output voltage. As a result, can minimise relative harmonic content despite change width of input voltage are wide because number of output voltage level of multi_level inverter does not decrease. Because proposed circuit manufactures is easy and control is easy and is no burden of cost price rise economically, commercialization expected to do easily and this study examined propriety of action as that compose and experiments proposed circuit.

  • PDF

A Study on Transformer Design of Multi-Level Converter (멀티레벨 컨버터의 변압기 설계에 대한 연구)

  • Kim, Chun-Sik;Kwon, Soon-Kurl;Lee, Hyun-Woo;Park, Sung-Woo;Chun, Jung-Ham
    • Proceedings of the KIEE Conference
    • /
    • 2003.04a
    • /
    • pp.303-305
    • /
    • 2003
  • This paper discusses single-phase AC-DC converter that driven by binary combination at different transformer winding ratio. It has a advantage that constructs a control system simply and obtain load current of good quality without filter circuit and free from noise or isolation for lower switching frequency. Also, this has merit that can do high power capacity. In this research, study on feedback circuit that consist for load stability of AC-DC multi-level converter.

  • PDF

Design Methodology of Multi-winding High-frequency Transformer for Solid-state Transformer (지능형 반도체 변압기용 다권선 고주파 변압기 설계 방안)

  • Park, Siho;Ryu, Myunghyo;Kim, Ho-sung;Cha, Honnyong
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.306-307
    • /
    • 2018
  • 본 논문은 지능형 반도체 변압기 (Solid-state transformer, SST)용 다권선 고주파 변압기의 최적 설계 방안을 제안한다. 설계된 변압기는 10 kHz의 스위칭 주파수를 운전 조건으로 하며, 60 kVA의 정격 용량을 가진다. 특히 13.2 kV의 중전압 계통에 적용하기 위해 30 kV 이상의 절연 내력으로 설계하였으며, SST 시스템의 부피가 커지는 것을 억제하기 위해 3 입력-1 출력으로 구성된 4-권선 방식으로 구성하였다. 절연 내력을 만족시키기 위해 teflon PTFE를 이용한 내부 보빈과 외부 보빈 및 가드를 제작하였으며, 누설 인덕턴스 최소화 및 근접 효과와 표피 효과로 인한 AC 손실을 최소화하기 위해 쉘-타입으로 설계하였다. 시제품 제작 후 60 kVA의 정격 하에 동작 검증을 완료하였으며, 내전압 시험을 이용하여 30 kV급의 절연 내력을 검증하였다.

  • PDF

Triple Delta Sourced Winding Structure of 4-winding Transformer for Multi-level Operation (멀티레벨 운전을 위한 4권선 변압기의 삼중 델타 전원 연결)

  • Ohn, Sung-Jae;Park, Yongsoon;Sul, Seung-Ki
    • Proceedings of the KIPE Conference
    • /
    • 2014.11a
    • /
    • pp.48-49
    • /
    • 2014
  • 본 논문에서는 4권선 변압기를 이용하여 멀티레벨 운전을 하는 새로운 결선 방식을 제안하였다. 일종의 개방형 권선 구조의 확장으로서, 동일한 하드웨어에서 결선만 바꿈으로써 2차단 권선에 인가되는 전압의 레벨 수를 늘릴 수 있다. 본 논문에서는 제안된 결선 방식에 대한 등가회로를 중첩원리를 이용하여 유도하였다. 제안된 결선 방식을 3개의 델타 결선된 권선에 적용하면, 2레벨 인버터를 사용하더라도 1개 권선의 전압을 합성하는 데 6개의 스위칭 상태가 관여하게 되어 권선 전압의 레벨수를 9개까지 늘일 수 있다. 제안된 회로의 등가회로를 도출하고 모의실험을 통해 등가회로의 타당성을 검증하였다.

  • PDF

Analysis and Design of DC-DC Converter with Independent Dual Outputs (독립적인 이중 출력을 갖는 DC-DC 컨버터의 해석 및 설계)

  • Heo, Tae-Won;Park, Ji-Ho;Kim, Dong-Wan;Woo, Jung-In
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.54 no.4
    • /
    • pp.171-178
    • /
    • 2005
  • The proposed dual-output DC-DC converter that bases on flyback converter can obtain two output voltage with non-isolated main-output and isolated sub-output at the same time using single-winding high frequency transformer. It can solve problems in multi-winding converter that use one main-switch, and also control quality of isolated sub-output voltage can be improved by additional sub-switch to the second. For analysis and design of the proposed converter system, converters are classified as operation mode from switching state and are become modeling by applying state space averaging method. Steady-state characteristics and dynamic characteristics are analyzed by DC component and perturbation component from state space averaging model. From experiment converter, validity of analysis and design for the propose converter system is confirm.

A Tightly Regulated Triple Output Asymmetrical Half Bridge Flyback Converter

  • Hyeon, Byeong-Cheol;Cho, Bo-Hyung
    • Journal of Power Electronics
    • /
    • v.10 no.1
    • /
    • pp.14-20
    • /
    • 2010
  • In this paper, a tightly regulated triple output asymmetrical half bridge flyback (ASHF) converter is proposed. In order to regulate all output voltages, pulse frequency modulation (PFM), pulse width modulation (PWM) and phase delay (PD) are used simultaneously. In comparison with the conventional PWM-PD method, the interactions among the control variables are minimized and the operating range is increased. By the utilization of a multi winding transformer, the auxiliary transformer and the blocking capacitor are eliminated and the size and cost of the proposed converter is reduced. The operation principle of the converter is explained and the modes of operation are investigated. Based on the results, the steady state characteristics of the converter are explored. A 24V/10A, 12V/5A, 5V/10A hardware prototype is built and tested to verify the analysis results and the voltage regulation of the triple outputs of the proposed converter.

A Study on the Three Phase Multi-PAM Inverter using the one-chip Microcomputer for UPS. (원칩 마이크로 컴퓨터를 이용한 UPS용 3상 다중 PAM 인버터에 관한 연구)

  • 김성백;이종규
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.3 no.2
    • /
    • pp.63-68
    • /
    • 1989
  • This paper discussed the Multi-PAM inverter for static power supply design. The controller part composed of one-chip microcomputer obtained control pattern simply. The configuration of termination part was composed of double bridge inverter and three-phase, three-winding transformer. The output waveforms using a controller and transformers synthesized the multi-PAM wave form by a voltage level of 22 steps per one-cycle. The output waveforms using the Low Pass Filter approximated to the sine wave.

  • PDF

New Double-Connected Multi-Step Inverter for High Power Motor Drive Applications (대용량 모터드라이브 적용을 위한 새로운 이중접속방식의 멀티스텝 인버터)

  • Yang, Seung-Uk;Choe, Gyu-Ha;Mok, Hyung-Soo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.3
    • /
    • pp.209-215
    • /
    • 2006
  • Now, in this paper, going to present you with an Idea related to a new inverter of multi-step voltage source, that Is, the double-connected 12-step inverter with an auxiliary circuit. It possibly can be 24-step inverter with 3-phase voltage source which will enable us make full application even to medium and high power-level Motor drive, UPS, STATCOM, SVC, etc. in which the PWM method could not be employed. 24-step operation can be obtained from the link between the existing 12-step inverter and the additional auxiliary circuit in which the transformer of auxiliary circuit generates ripple voltage delivered to the inverter. Through a lot of experiments and simulations, (from which the validity of this scheme is confirmed,) we came to the conclusion that the increase of the primary winding number on transformer by 2N(N=1,2,3....) leads to the 12M-step(M=2,3,4...) inverter. The validity of the proposed scheme is confirmed by the simulated and experimental results.

A Inverter Design of Reversible Power Converter (가역 전력변환기의 인버터 설계)

  • Chun, J.H.;Lee, H.W.;Baek, S.H.;Kwak, D.K.
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.8-13
    • /
    • 2005
  • In this paper discusses single-phase DC-AC Inverter design of reversible power converter that driven by binary combination at different transformer winding ratio by BCD code level. It has a advantage that constructs a control system simply and obtain load current of good quality without filter circuit and free from noise or isolation for lower switching frequency. In this research, study on current type converter and inverter circuit that consist for possibility of AC-DC/DC-AC multi-level reversible converter.

  • PDF