• 제목/요약/키워드: Mu-Scan

검색결과 242건 처리시간 0.032초

${\mu}$-합성법을 이용한 탐색기 주사루프의 강인 제어 (Robust Control of a Seeker Scan Loop System Using ${\mu}$-Systheis)

  • 이호평
    • 한국정밀공학회지
    • /
    • 제16권3호통권96호
    • /
    • pp.180-188
    • /
    • 1999
  • ${\mu}$-synthesis is applied to design a robust controller for a seeker scan loop system which has model uncertainty and is subject to a external disturbance due to abrupt missile maneuver. The issue of modelling a real-valued parametric uncertainty of a physical seeker scan loop system is discussed. The two-degree-of-frame control structure is employed to obtain better performance. It is shown that ${\mu}$-synthesis provides a superior framework for the robust control design of a seeker scan loop system which exhibits robust performance. The proposed robust control system satisfies design requirements, and especially shows good scanning performances for conical and rosette scan patterns despite parametric uncertainty in real system model.

  • PDF

Add-picture 방법을 이용한 교합접촉점 분석 (Analysis of Occlusal Contacts Using Add-picture Method)

  • 박고운;조리라;김대곤;박찬진
    • 구강회복응용과학지
    • /
    • 제29권1호
    • /
    • pp.45-58
    • /
    • 2013
  • 교합접촉 분석에 이용되는 T-Scan $III^{(R)}$ (Tekscan, South Boston, MA, USA)의 정확도 및 신뢰도를 Add picture 방법을 통해 평가하였다. 두 방법에서 공통적인 교합접촉점의 분포 및 교합접촉면적을 비교하여 교합진단 및 조정 술식에서 T-Scan 방법의 적용 시 고려점을 밝히고자 하였다. Angle I급 교합관계, 정상치열자 한 사람의 구강을 대상으로 부가중합형 실리콘인상재를 이용하여 상하악치열궁을 10회 인상채득하였으며, 10쌍의 초경석고 모형을 제작하였다. 자체제작한 하중장치에 모형을 자석과 경석고를 이용하여 부착한 후 최대감합위와 최대교합력을 재현하기 위해 78.9kg의 하중을 가하였다. T-Scan 측정 시에는 상하악 모형과 T-Scan 센서의 위치가 변하지 않는 상태에서 2번 반복 측정하였다. Add Picture의 경우 상하악모형을 동일한 하중을 가하여 최대감합위에서 폴리이써 교합인기재를 이용하여 교합을 인기하였다. 교합접촉 양상은 접촉점 수와 총 교합면적에 대한 접촉면적 백분율을 측정하여 비교하였다. T-Scan 방법은 포토샵 프로그램 상에서 픽셀수를 계산하여 색상에 따른 면적을, Add picture 방법은 빛 투과 정도에 따라 인상재 두께를 $0{\sim}10{\mu}m$, $0{\sim}30{\mu}m$, $0{\sim}60{\mu}m$의 3가지로 나누고, 이에 따른 면적을 실측하여 계산하였다. 총 교합면면적은 접촉면을 표시한 모형의 촬영상에서 픽셀수를 계산하여 함께 촬영된 격자를 기준으로 제곱미터값으로 변환하였다. 대응표본 t-검정을 이용하여 통계분석하였다. T-Scan 방법에서 분홍색상 및 붉은 색상으로 표시된 면적의 일부가 Add picture 방법에서 $0{\sim}10{\mu}m$, $0{\sim}30{\mu}m$, $0{\sim}60{\mu}m$의 상하악 치아 간 거리에 해당하는 면적에 상응하였다. 교합접촉점 분포 비교 시 T-Scan 방법과 Add picture 방법은 유사하였다. 교합접촉면적 비교 시 T-Scan 방법에서 확대된 결과가 관찰되었으며, 전체교합면적에 대한 접촉면적 백분율 비교에서도 T-Scan 방법과 Add picture 방법의 백분율값은 유의한 차이를 보였다(P<.05). T-Scan에서 분홍색상 및 붉은 색상으로 표시된 부위의 면적값은 Add picture의 $0{\sim}10{\mu}m$, $0{\sim}30{\mu}m$ 부위의 면적값보다 크고(P<.05), $0{\sim}60{\mu}m$ 부위와는 유사한 값을 보였다(P>.05). T-Scan에서의 교합접촉상은 실제보다 확대되어 나타났으며, 따라서 교합접촉에 대한 진단 및 조정 술식에서 보조적인 수단으로 활용하는 것이 추천된다.

Replica technique과 Triple-scan protocol을 이용한 지르코니아 전부도재관의 변연 및 내면 적합도에 관한 비교 연구 (Marginal and internal fit of all ceramic crown using the replica technique and the triple-scan protocol)

  • 신미선;이장훈
    • 대한치과보철학회지
    • /
    • 제55권4호
    • /
    • pp.372-380
    • /
    • 2017
  • 목적: 본 연구는 보철물의 적합도를 계측하는 두 가지의 측정방법을 평가하기 위해 지르코니아로 전부도재관을 제작하고 replica technique과 triple-scan protocol을 이용하여 전부도재관의 변연 및 내면 적합도를 비교 연구하고자 하였다. 재료 및 방법: 타이타늄의 지대치 모형을 제작하여 20개의 지르코니아 전부도재관을 제작하였다. 제작된 지르코니아 전부도재관 10개는 replica technique을 이용해 복제하고 복제된 시편을 협설, 근원심으로 절단하여 변연 및 내면 적합도를 측정하였고, 다른 10개의 전부도재관은 triple-scan protocol을 이용하여 협설과 근원심으로 단면을 형성하고 변연 및 내면 적합도를 계측하여 통계 분석하였다 (${\alpha}=.05$). 결과: 변연과 내면 적합도는 replica technique $49.86{\pm}29.69{\mu}m$, triple-scan protocol $75.35{\pm}64.73{\mu}m$로 유의한 차이가 있었고 (P < .001), 내면 적합도만을 측정한 결과 각각 $58.38{\pm}31.77{\mu}m$, $64.00{\pm}46.43{\mu}m$로 유의한 차이가 없었다 (P > .343). 결론: Replica technique과 triple-scan protocol을 이용하여 전부도재관의 변연 및 내면 적합도를 비교 측정한 결과 triple-scan protocol에서의 변연 적합도가 크게 측정되었고, 내면 적합도만 비교해 본 결과 통계적인 유의한 차이가 없었다.

화학기상증착 다이아몬드 막의 레이저 평탄화 (Lapping of Chemical Vapor Deposited Diamond Films Using copper Vapor laser)

  • 박영준;백영준
    • 한국세라믹학회지
    • /
    • 제36권4호
    • /
    • pp.417-424
    • /
    • 1999
  • Laser lapping of diamond films is performed with focused beam of copper vapor laser. Both spherical and rod-shape laser beam are used. Diamond surface is scanned at various scan speeds(0,125, 0.5, 0.75 mm/sec) and baem shifts (5, 10, 20, 40, 100$\mu\textrm{m}$) At 0.125 mm/sec 10$\mu\textrm{m}$ scan condition the level difference of di-amond surface of about 700$\mu\textrm{m}$ over 20 mm is reduced to 200$\mu\textrm{m}$ In addition surface roughness is also im-proved from 3.53$\mu\textrm{m}$ to 2.47$\mu\textrm{m}$ at 5$\mu\textrm{m}$ beam shift. But at higher beam shift than 10$\mu\textrm{m}$ laser scan makes the surface rougher which is considered to be due to the non uniform spatial distribution of laser en-ergy. It is concluded that homogenized laser beam with high average power is needed for large area laser lapping of diamond films at appreciable rates.

  • PDF

국산 치과용 구강스캐너(e-scanner)와 모델스캐너의 정확도 비교 (Comparison of the accuracy of domestic dental intra-oral scanner(e-scanner) and model scanner)

  • 김부섭;김정호
    • 대한치과기공학회지
    • /
    • 제41권2호
    • /
    • pp.53-61
    • /
    • 2019
  • Purpose: The purpose of this study is to evaluate the discrepancy of scan process in dental intra oral scanner by comparing model scanner and anticipate possibility to introduce intra oral scan technique. Methods: 3D superimposition test was conducted to compare the scan discrepancy. The scanners used in this study are the e-oral scanner, the D750 model scanner, and the high precision CMM(3D Coordinate Measuring Machine). The standard of accuracy verification is ISO 5725-1; trueness and precision. Master model was manufactured by dental stone and scanned 5 times by intra oral, model scanner. Reference data was scanned 5 times by high accuracy CMM to evaluate the trueness. Results: Trueness of D750 scanner were $7.4{\mu}m$ $5.1{\mu}m$ $6.8{\mu}m$ at an abutment, an occluasal, a specific area. and trueness of e-scanner were $20.2{\mu}m$ $27.4{\mu}m$ $37.8{\mu}m$ at an abutment, an occluasal, a specific area. Precision of D750 scanner was $7.04{\mu}m$, e-scanner was $15.95{\mu}m$. Conclusion: When conducting in vitro test, The mean difference of trueness between e-scanner and D750 were $12.8{\mu}m$ at an abutment area, $22.3{\mu}m$ at an occlusal area, $31.0{\mu}m$ at a specific area and $8.91{\mu}m$ in precision. The scan discrepancies are within the range of clinical acceptance.

PERFORMANCE TEST FOR A PDS MICRODENSITOMETER MODEL 1010GMS

  • Hong, S.S.;Paek, W.G.;Lee, S.G.
    • 천문학회지
    • /
    • 제25권1호
    • /
    • pp.23-46
    • /
    • 1992
  • The electrical, mechanical and optical capabilities have been tested of the microdensitometer PDS 1010GMS at the Korea Astronomy Observatory. The highest stage of scan speed 255 csu (conventional speed unit) is measured to be 47 mm/s. At this speed the position is displaced by $4{\mu}m$ to the direction of scanning and the density is underestimated by $0.4{\sim}0.7D$. Standard deviation in the measured density is proportional to $A^{-0.46}$, where A is the area of scan aperture. The accuracy of position repeatability is ${\pm}1{\mu}m$, and that of density repeatability is ${\pm}(0.003{\sim}0.03)D$. Callier coefficient is determined to be 1.37; the semispecular density is directly proportional to the diffuse density up to 3.5D. Because the logarithmic amplifier has a finite response time, the densities measured at high scan speeds are underestimated to the degree that speeds higher than 200 csu are inadequate for making an accurate astronomical photometry. After power is on, an about 5 hour period of warming is required to stabilize the system electrically and mechanically as well. On the basis of this performance test, we have determined the followings as the optimum scan parameters for the astronomical photometry: For the scan aperture $10\;\sim\;20{\mu}m$ is optimal, and for the scan speed. $20\;{\sim}\;50$ csu is appropriate. These parameter values are chosen in such a way that they may keep the density repeatability within ${\pm}0.01D$, the position displacement under $1{\mu}m$, and the density underestimation below 0.1D even in high density regions.

  • PDF

플라스틱 f$\heta$렌즈의 복굴절이 결상빔경에 미치는 영향분석 (The effect analysis of birefringence of plastic f$\heta$ Iens on the beam diameter)

  • 임천석
    • 한국광학회지
    • /
    • 제11권2호
    • /
    • pp.73-79
    • /
    • 2000
  • 사출성형법으로 제조된 $fheta$렌즈를 주사렌즈로 상요하는 Laser Scanning Unit의 주주사 및 부주사 방향의 빔경을 측정했다. 주주사 빔경의 경우 $62muextrm{m}$~ $68\mu\textrm{m}$로써 설계치와 유사한 성능을 보이지만 부주사 빔경의 경우 $78\mu\textrm{m}$~$115\mu\textrm{m}$로써 꽤 큰 빔경편차( $37\mu\textrm{m}$)를 나타내었다. 사출성형렌즈에서는 냉각.고화시 수축에 의한 형상오차와 불균일 냉각에 의한 내부왜곡(복굴절)이 발생하게 되는데, 이는 결국 파면수차(빔경확대)를 발생시키게 되고 결국 레이저프린터의 화상열화로 나타나게 된다. 본 논문에서는 부주사 빔경편차의 주요인을 밝혀내기 위해 복굴절(편광비) 및 $f\theta$렌즈의 비구면 형상을 측정하였다. 그리고 측정된 비구면 형상치를 CODE-V(미국 ORA사의 광학설계 프로그램)에 입력하여 부주사 상면만곡을 계산하고, 이와 설계 초점심도를 비교.분석함으로써 복굴절이 부주사 빔경편차의 주요인임을 알 수 있었다.

  • PDF

PVDF 수침용 고주파수 초음파 탐촉자의 검출장과 Cr-Ni 강에서의 결함 검출능 측정 (Characteristics of High Frequency Ultrasonic Transducer Employing Polyvinylidene Fluoride and Detectability of Flaw in Cr-Ni Steel)

  • 김병극;이승석
    • 비파괴검사학회지
    • /
    • 제17권1호
    • /
    • pp.23-30
    • /
    • 1997
  • 최근 시료 내부의 미세 결함의 측정을 위하여 초음파의 발생 소자로 polyvinylidene fluoride(PVDF)나 polyvinylidene fluoride trifluoroethylene P(VDF-TrFE) 압전 재료를 사용한 광대역 고주파수 초음파 탐촉자가 이용되고 있다. 중심 주파수 80MHz의 PVDF 수침용 집속형 초음파 탐촉자의 특성과 물과 시료에서의 초음파의 검출장을 측정하였으며 강재 시편에서의 결함 검출능을 측정하였다. 물과 강재 시험편에서 고주파수 초음파의 감쇠가 결함 검출능을 좌우하는 주요 변수이었다. 작은 결정립을 지닌 크롬-니켈강 재료를 사용하여 12mm 깊이에 직경 $50{\mu}m$에서 $560{\mu}m$ 범위의 flat-bottom hole들을 가공한 시편을 준비하였고 C-scan과 B-scan을 수행하였다. 직경 $280{\mu}m$ 이상의 flat-bottom hole들은 검출되었고 파장에 대한 결함 크기의 비가 약 0.48 이하의 결함은 검출되지 않았다. 시편에 초음파의 고주파수 성분이 입사되었으나 약 25MHz 이상의 고주파수 성분이 시편내의 초음파의 전파 경로에서 모두 감쇠되어 더 작은 결함에 대한 검출장이 형성되지 못했다.

  • PDF

방사성 동위원소를 이용한 핵의학과 검사에서 병동 간호사의 방사선 피폭선량 평가 (Evaluation of Radiation Exposure to Nurse on Nuclear Medicine Examination by Use Radioisotope)

  • 정재훈;이충운;유연욱;서영덕;최호용;김윤철;김용근;원우재
    • 핵의학기술
    • /
    • 제21권1호
    • /
    • pp.44-49
    • /
    • 2017
  • 목적: 핵의학 검사를 시행한 병동 환자의 시간과 거리에 따른 방사선량률을 측정하여 방사성동위원소 투여를 받은 환자가 병동 간호사에게 미치는 피폭을 예측하고 실제 총 피폭량과 비교하여 보고자 한다. 대상 및 방법: 병동에서 근무하고 있는 간호사 14명을 대상으로 열형광 선량계와 광자극 선량계를 이용하여 방사선 피폭선량을 측정하였고 핵의학 검사를 시행한 환자 50명(PET/CT 20명, Bone scan 20명, Myocardial SPECT 10명)을 대상으로 방사성동위원소 투여 직후와 검사시행 직후에 표면, 50cm, 1m에서 외부 방사선량률을 측정하였다. 측정 결과를 바탕으로 유효반감기를 도출한 후 병동 간호사가 받을 수 있는 피폭량을 예측하였다. 그리고 열형광선량계와 광자극선량계로 측정된 병동 간호사의 실제 총 피폭량과 비교 하였다. 결과: 병동 간호사 14명을 대상으로 한 피폭선량 측정결과 평균값과 최대값은 각각 분기당 0.01 mSv, 0.02 mSv 이었고 핵의학 검사를 시행 받은 환자의 선량률은 표면, 50cm, 1m 거리 순으로 PET/CT는 $376.0{\pm}25.2{\mu}Sv/hr$, $88.1{\pm}8.2{\mu}Sv/hr$, $29.0{\pm}5.8{\mu}Sv/hr$ 이고 Bone scan은 $206.7{\pm}56.6{\mu}Sv/hr$, $23.1{\pm}4.4{\mu}Sv/hr$, $10.1{\pm}1.4{\mu}Sv/hr$이고 Myocardial SPECT는 $22.5{\pm}2.6{\mu}Sv/hr$, $2.4{\pm}0.7{\mu}Sv/hr$, $0.9{\pm}0.2{\mu}Sv/hr$이다. 또한 검사를 시행한 후 측정한 선량률은 표면, 50cm, 1m 거리 순으로 PET/CT는 $165.3{\pm}22.1{\mu}Sv/hr$, $38.7{\pm}5.9{\mu}Sv/hr$, $12.4{\pm}2.5{\mu}Sv/hr$ 이고 Bone scan은 $32.1{\pm}8.7{\mu}Sv/hr$, $6.2{\pm}1.1{\mu}Sv/hr$, $2.8{\pm}0.6{\mu}Sv/hr$이고 Myocardial SPECT는 $14.0{\pm}1.2{\mu}Sv/hr$, $2.1{\pm}0.3{\mu}Sv/hr$, $0.8{\pm}0.2{\mu}Sv/hr$이다. 위의 결과를 바탕으로 유효반감기를 도출한 후 검사종료 30분 후 원자력안전법에서 규정하는 일반인 선량한도까지 도달하는데 걸리는 시간을 반감기를 고려치 않고 보수적으로 계산하면 PET/CT는 표면, 50cm, 1m 거리 순으로 7.9시간, 34.1시간, 106.8시간이며 Bone scan은 40.4시간, 199.5시간, 451.1시간이고 Myocardial SPECT는 62.5시간, 519.3시간, 1313.6시간이다. 결론: 본 연구 결과에 의하면 병동 간호사는 일반인 선량한도 보다 훨씬 적은 피폭량을 받는 것으로 나타나, 실질적으로 판단할 때 핵의학 검사를 시행한 환자로 인하여 받는 피폭의 영향은 미미한 것으로 판단된다.

  • PDF

선택적 레이저 용융 공정시 용융 거동에 대한 공정 분석 (Process Analysis of Melting Behaviors in Selective Laser Melting Process)

  • 성민영;주병돈;김수희;문영훈
    • 소성∙가공
    • /
    • 제19권8호
    • /
    • pp.517-522
    • /
    • 2010
  • Selective laser melting (SLM) is emerged as a new manufacturing technique to directly fabricate precise parts using metallic materials. The final characteristics of a component fabricated through the SLM process are strongly dependent upon various parameters such as laser power, scan rate and pulse duration, etc. This paper, therefore, focuses on the dimensional characteristics of melted $20{\mu}m$ Fe-Cr-Ni powder by fiber laser for the selective laser melting process. With energy density decrease, the height and depth were decreased. Although the conditions are of the same energy density, the shape is different by laser power and scan rate. The shapes at various laser parameters were divided into 3 groups based on depth over height. The smooth regular shape is obtained under the conditions of $50{\mu}m$ of powder height and $15-20{\mu}s$ of pulse duration. And the laser power influenced the variation of shape more significantly than the scan rate.