Marginal and internal fit of all ceramic crown using the replica technique and the triple-scan protocol

Replica technique과 Triple-scan protocol을 이용한 지르코니아 전부도재관의 변연 및 내면 적합도에 관한 비교 연구

  • Shin, Mi-Sun (Department of Convergence Technology, Graduate School of Venture, Hoseo University) ;
  • Lee, Jang-Hoon (Division of Architecture, Civil and Environmental Engineering, Hoseo University)
  • 신미선 (호서대학교 벤처대학원 융합공학과) ;
  • 이장훈 (호서대학교 건축토목환경공학부)
  • Received : 2017.06.12
  • Accepted : 2017.09.04
  • Published : 2017.10.31

Abstract

This study was conducted to compare the marginal and internal fit of all ceramic crown using the replica technique and the triple-scan protocol. Materials and methods: Twenty zirconia ceramic crowns were fabricated using titanium abutment model. All crowns were divided into two groups of 10 each, depending on the replica technique and the triple-scan protocol. The internal and marginal fit of 10 zirconia ceramic crowns were measured at 17 points for each specimen using the replica technique. The other 10 ceramic crowns were measured using the triple-scan protocol. Statistical analysis was performed by t-test (${\alpha}=.05$). Results: The mean and standard deviation of marginal and internal fit were significantly different between the replica technique ($49.86{\pm}29.69{\mu}m$) and triple-scan protocol ($75.35{\pm}64.73{\mu}m$, P<.001). The mean and standard deviation of internal fit except marginal fit were $58.38{\pm}31.77{\mu}m$ and $64.00{\pm}46.43{\mu}m$, respectively (P>.343). Conclusion: There was a statistically significant difference in the marginal fit measured by the two methods. However, there was no statistically significant difference in the internal fit between the two methods.

목적: 본 연구는 보철물의 적합도를 계측하는 두 가지의 측정방법을 평가하기 위해 지르코니아로 전부도재관을 제작하고 replica technique과 triple-scan protocol을 이용하여 전부도재관의 변연 및 내면 적합도를 비교 연구하고자 하였다. 재료 및 방법: 타이타늄의 지대치 모형을 제작하여 20개의 지르코니아 전부도재관을 제작하였다. 제작된 지르코니아 전부도재관 10개는 replica technique을 이용해 복제하고 복제된 시편을 협설, 근원심으로 절단하여 변연 및 내면 적합도를 측정하였고, 다른 10개의 전부도재관은 triple-scan protocol을 이용하여 협설과 근원심으로 단면을 형성하고 변연 및 내면 적합도를 계측하여 통계 분석하였다 (${\alpha}=.05$). 결과: 변연과 내면 적합도는 replica technique $49.86{\pm}29.69{\mu}m$, triple-scan protocol $75.35{\pm}64.73{\mu}m$로 유의한 차이가 있었고 (P < .001), 내면 적합도만을 측정한 결과 각각 $58.38{\pm}31.77{\mu}m$, $64.00{\pm}46.43{\mu}m$로 유의한 차이가 없었다 (P > .343). 결론: Replica technique과 triple-scan protocol을 이용하여 전부도재관의 변연 및 내면 적합도를 비교 측정한 결과 triple-scan protocol에서의 변연 적합도가 크게 측정되었고, 내면 적합도만 비교해 본 결과 통계적인 유의한 차이가 없었다.

Keywords

References

  1. Jacobs MS, Windeler AS. An investigation of dental luting cement solubility as a function of the marginal gap. J Prosthet Dent 1991;65:436-42. https://doi.org/10.1016/0022-3913(91)90239-S
  2. Knoernschild KL, Campbell SD. Periodontal tissue responses after insertion of artificial crowns and fixed partial dentures. J Prosthet Dent 2000;84:492-8. https://doi.org/10.1067/mpr.2000.110262
  3. Sailer I, Feher A, Filser F, Gauckler LJ, Luthy H, Hammerle CH. Five-year clinical results of zirconia frameworks for posterior fixed partial dentures. Int J Prosthodont 2007;20:383-8.
  4. Ko IS, Kim JM, Cho HW. Comparison of micro CT and crosssection technique for evaluation of marginal and internal fit of lithium disilicate crowns. J Korean Acad Prosthodont 2016;54:226-33. https://doi.org/10.4047/jkap.2016.54.3.226
  5. Contrepois M, Soenen A, Bartala M, Laviole O. Marginal adaptation of ceramic crowns: a systematic review. J Prosthet Dent 2013;110:447-454.e10. https://doi.org/10.1016/j.prosdent.2013.08.003
  6. Rahme HY, Tehini GE, Adib SM, Ardo AS, Rifai KT. In vitro evaluation of the "replica technique" in the measurement of the fit of Procera crowns. J Contemp Dent Pract 2008;9:25-32.
  7. Holst S, Karl M, Wichmann M, Matta RE. A new triple-scan protocol for 3D fit assessment of dental restorations. Quintessence Int 2011;42:651-7.
  8. Planitz BM, Maeder AJ, Williams JA. The correspondence framework for 3D surface matching algorithms. Comput Vis Image Underst 2005;97:347-83. https://doi.org/10.1016/j.cviu.2004.08.001
  9. Besl PJ, McKay ND. A method for registration of 3-D shapes. IEEE Trans Pattern Anal Mach Intell 1992;14:239-56. https://doi.org/10.1109/34.121791
  10. Akca D. A new algorithm for 3D surface matching. 20th ISPRS Congress, Istanbul, Turkey, July 12-23, 2004. IAPRS& SIS, 2004;35(B7):960-65.
  11. Holmes JR, Bayne SC, Holland GA, Sulik WD. Considerations in measurement of marginal fit. J Prosthet Dent 1989;62:405-8. https://doi.org/10.1016/0022-3913(89)90170-4
  12. Moon BH, Yang JH, Lee SH, Chung HY. A study on the marginal fit of all-ceramic crown using CCD camera. J Korean Acad Prosthodont 1998;36:273-92.
  13. McLean JW, von Fraunhofer JA. The estimation of cement film thickness by an in vivo technique. Br Dent J 1971;131:107-11. https://doi.org/10.1038/sj.bdj.4802708
  14. Gulker I. Margins. N Y State Dent J 1985;51:213-5, 217.
  15. Moldovan O, Rudolph H, Quaas S, Bornemann G, Luthardt RG. Internal and external fit of CAM-made zirconia bridge frameworksa pilot study. Dtsch Zahnarztl Z 2006;61:38-42.
  16. Molin MK, Karlsson SL, Kristiansen MS. Influence of film thickness on joint bend strength of a ceramic/resin composite joint. Dent Mater 1996;12:245-9. https://doi.org/10.1016/S0109-5641(96)80030-3
  17. Mormann WH, Bindl A, Luthy H, Rathke A. Effects of preparation and luting system on all-ceramic computer-generated crowns. Int J Prosthodont 1998;11:333-9.
  18. Sorensen JA, Munksgaard EC. Interfacial gaps of resin cemented ceramic inlays. Eur J Oral Sci 1995;103:116-20. https://doi.org/10.1111/j.1600-0722.1995.tb00128.x
  19. Huh JB, Kim U, Kim HY, Kim JE, Lee JY, Kim YS, Jeon YC, Shin SW. Marginal and internal fitness of three-unit zirconia cores fabricated using several CAD/CAM systems. J Korean Acad Prosthodont 2001;49:236-44.
  20. Groten M, Girthofer S, Probster L. Marginal fit consistency of copy-milled all-ceramic crowns during fabrication by light and scanning electron microscopic analysis in vitro. J Oral Rehabil 1997;24:871-81. https://doi.org/10.1046/j.1365-2842.1997.00592.x
  21. Kim H, Pae A. Marginal and internal fit of lithium disilicate crowns assessed by the triple-scan protocol. MSD thesis, Kyunghee University, 2017.
  22. Pimenta MA, Frasca LC, Lopes R, Rivaldo E. Evaluation of marginal and internal fit of ceramic and metallic crown copings using x-ray microtomography (micro-CT) technology. J Prosthet Dent 2015;114:223-8. https://doi.org/10.1016/j.prosdent.2015.02.002
  23. Matta RE, Schmitt J, Wichmann M, Holst S. Circumferential fit assessment of CAD/CAM single crowns-a pilot investigation on a new virtual analytical protocol. Quintessence Int 2012;43:801-9.
  24. Lee DH. Digital approach to assessing the 3-dimensional misfit of fixed dental prostheses. J Prosthet Dent 2016;116:836-9. https://doi.org/10.1016/j.prosdent.2016.05.012
  25. Park JM, Hammerle CH, Benic GI. Digital technique for in vivo assessment of internal and marginal fit of fixed dental prostheses. J Prosthet Dent 2017 Mar 23. pii: S0022-3913(17)30008-2.
  26. Pelekanos S, Koumanou M, Koutayas SO, Zinelis S, Eliades G. Micro-CT evaluation of the marginal fit of different In-Ceram alumina copings. Eur J Esthet Dent 2009;4:278-92.
  27. Neves FD, Prado CJ, Prudente MS, Carneiro TA, Zancope K, Davi LR, Mendonca G, Cooper LF, Soares CJ. Micro-computed tomography evaluation of marginal fit of lithium disilicate crowns fabricated by using chairside CAD/CAM systems or the heat-pressing technique. J Prosthet Dent 2014;112:1134-40. https://doi.org/10.1016/j.prosdent.2014.04.028

Cited by

  1. 밀링 공구의 마모가 PMMA 임플란트 임시보철물 변연 및 내면적합도에 미치는 영향 vol.41, pp.2, 2017, https://doi.org/10.14347/kadt.2019.41.2.63