• Title/Summary/Keyword: Modified electrode

Search Result 494, Processing Time 0.022 seconds

Bioelectrocatalyzed Signal Amplification for Affinity Interactions at Chemically Modified Electrodes

  • Hyun C. Yoon;Kim, Hak-Sung
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.9 no.2
    • /
    • pp.107-111
    • /
    • 2004
  • A comparative study was performed to evaluate the signal amplification strategies in electrochemical affinity sensing, which included the direct electron transfer and diffusible-group mediated electron transfer between label enzymes that were specifically bound to target proteins and chemically modified electrode surfaces. As a platform surface for affinity recognition reactions, a double functionalized poly(amidoamine) dendrimer monolayer that was modified with ferrocene and biotin groups was constructed on a gold surface. With the chemically modified electrode, a model affinity sensing with avidin was investigated. The advantages of adopting the diffusible-group mediated signaling strategy were demonstrated in terms of signal sensitivity and stability.

SAMs of 2-Aminoethanethiol Modified with 3,4-Dihydroxyphenylalanine for the Electrocatalytic Oxidation of NADH on Gold Electrodes

  • Cha, Seong-Keuck
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.6
    • /
    • pp.786-790
    • /
    • 2004
  • 2-Aminoethanethiol (aet) has been used to make self-assembled monolayer (SAMs) on gold electrodes, which are subsequently modified with 3,4-dihydroxy phenylalanine (dpa). Such modified electrodes having various types of Au/aet-dpa were employed in the electrocatalytic oxidation of NADH. The purpose of this study to characterize the responses of such modified electrodes in terms of the immobilization procedure, pH of the solution and applied potential. The reaction of the surface immobilized dpa with NADH was studied using the rotating disk electrode technique and a value of $2.2{\times}10^4M^{-1}s^{-1}$ was obtained for the second-order rate constant in 0.1 M Tris/$NO_3^-$buffer (pH=8.0). The hydration behavior of the films was characterized by quartz crystal microbalance. When used as a NADH sensor, the Au/aet-dpa electrode exhibited good sensitivity and an excellent correlation (r ${\geq}$ 0.99) for NADH concentration which extended to $3.8{\times}10^{-3}$ M.

Characteristics of ${\alpha}$-Cyclodextrin Modified Carbon Paste Electrode (${\alpha}$-Cyclodextrin으로 화학수식된 Carbon Paste 전극의 특성)

  • Jeon, Young-Guk;Kim, Bong-Weon;Kim, Hee-Jung;Cho, Young-Dal;Chung, Chinkap
    • Analytical Science and Technology
    • /
    • v.9 no.3
    • /
    • pp.235-243
    • /
    • 1996
  • A carbon paste electrode were chemically modified using ${\alpha}$-cyclodextrin. Characteristics of chemically modified carbon paste electrodes were studied on the basis of the inclusion complex formation of ${\alpha}$-cyclodextrin and p-nitrophenol in solution. Cyclic voltammetry and differential pulse voltammetry were used to monitor the efficiency of the chemical modification. When the ${\alpha}$-cyclodextrin and carbon powder ratio of 2 : 1 in weight were used, the reduction peak current of p-nitrophenol was decreased almost completely, whereas those of o-nitrophenol and hydroquinone were not changed much. This result is due to the large difference in the inclusion complex formation constants of p-nitrophenol and the other probes with ${\alpha}$-cyclodextrin. Taking advantage of this difference, we can determine the concentration of o-nitrophenol even in the presence of p-nitrophenol.

  • PDF

Voltammetric Determination of Copper(II) Using Glassy Carbon Electrodes Modified with Nafion-DTPA-Glycerol

  • Park, Chan-Ju;Park, Eun-Heui;Chung, Keun-Ho
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2003.06a
    • /
    • pp.177-180
    • /
    • 2003
  • A glassy carbon electrode(GCE) modified with nafion-DTPA-glycerol was used for the highly selective and sensitive determination of a trace amount of Cu$\^$2+/. Various experimental parameters, which influenced the response of nafion-DTPA-glycerol modified electrode to Cu$\^$2+/, were optimized. The copper(II) was accumulated on the electrode surface by the formation of the complex in an open circuit, and the resulting surface was characterized by medium exchange, electrochemical reduction, and differential pulse voltammetry, A linear range was obtained in the concentration range 1.0${\times}$10$\^$-8/M∼1.0${\times}$10$\^$-6/M Cu(II) with 7 min preconcentration. Further, when an approximate amount of lead(II) is added to the test solution, nafion-DTPA-glycerol modified glassy carbon electrode has a dynamic range of 2 orders magnitude(1.0${\times}$10$\^$-9/M∼1.0${\times}$10$\^$-7/M). The detection limit(3 $\sigma$) was as low as 5.0${\times}$10$\^$-6/M(0.032ppb). The interferences from other metal ions could be reduced by adding KCN into the sample solutions. This method was applied to the determination of coppe,(II) in certified reference material(3.23${\times}$10$\^$-7/M, 21ppb), sea water(9.50${\times}$10/sup-7/M, 60ppb). The result agrees satisfactorily with the value measured by Korea Research Institute of Standard and Science.

  • PDF

Deposition of Uranium Ions with Modified Pyrrole Polymer Film Electrode (우라늄이온 포집을 위한 수식된 피를 고분자 피막전극)

  • Cha Seong-Keuck;Lee Sang Bong
    • Journal of the Korean Electrochemical Society
    • /
    • v.3 no.3
    • /
    • pp.141-145
    • /
    • 2000
  • Anodically Polymerized conducting Polypyrrole film electrode was employed to Pick up uranyl ion with the type of Gr/ppy, xylenol orange modified electrode. To have Porous and oriented ppy film, NBR was applied as precoating agent. The rate constant of polymerization was $3.22\times10^{-3}s^{-1}$ which was 1.6 times smaller value than bare graphite surface. The deposited amount of uranyl iou on $1.70Ccm^{-2}$ of ppy was $1.55\times10^{-4}g$. The matrix effect in artificial seawater was $6.8\%$. The polymer film electrode has a diffusion controlled process in conduction, but the modified Gr/ppy, $X.O^{4-}UO^+$ type was influenced on the ion doping and electronic conduction of film itself owing to increasing of impedance. The capacitance of electrical double layer was respectively enhanced to 56 and 130 times in Gr/ppy, $X.O.^{4-}$ and Gr/ppy, $X.O^{4-}UO^+$ than Grippy type electrode.

Nanostructured Metal Organic Framework Modified Glassy Carbon Electrode as a High Efficient Non-Enzymatic Amperometric Sensor for Electrochemical Detection of H2O2

  • Naseri, Maryam;Fotouhi, Lida;Ehsani, Ali
    • Journal of Electrochemical Science and Technology
    • /
    • v.9 no.1
    • /
    • pp.28-36
    • /
    • 2018
  • Metal-organic frameworks have recently been considered very promising modifiers in electrochemical analysis due to their unique characteristics among which tunable pore sizes, crystalline ordered structures, large surface areas and chemical tenability are worth noting. In the present research, $Cu(btec)_{0.5}DMF$ was electrodeposited on the surface of glassy carbon electrode at room temperature under cathodic potential and was initially used as the active materials for the detection of $H_2O_2$. The cyclic voltammogram of $Cu(btec)_{0.5}DMF$ modified GC electrode shows distinct redox peaks potentials at +0.002 and +0.212 V in 0.1 M phosphate buffer solution (pH 6.5) corresponding to $Cu^{(II)}/Cu^{(I)}$ in $Cu(btec)_{0.5}DMF$. Acting as the electrode materials of a non-enzymatic $H_2O_2$ biosensor, the $Cu(btec)_{0.5}DMF$ brings about a promising electrocatalytic performance. The high electrocatalytic activity of the $Cu(btec)_{0.5}DMF$ modified GC electrode is demonstrated by the amperometric response towards $H_2O_2$ reduction with a wide linear range from $5{\mu}M$ to $8000{\mu}M$, a low detection limit of $0.865{\mu}M$, good stability and high selectivity at an applied potential of -0.2 V, which was higher than some $H_2O_2$ biosensors.

Relative Comparison of Cathode Polarizations in Solid Oxide Fuel Cells Using the Spreading Concept in AC 2 Point Impedance Spectroscopy

  • Lee, Byung-Kook;Kim, Eui-Hyun;Hwang, Jin-Ha
    • Journal of the Korean Ceramic Society
    • /
    • v.50 no.2
    • /
    • pp.163-167
    • /
    • 2013
  • A modified two-point impedance spectroscopy technique exploits the geometric constriction between an electrolyte and a cathode with an emphasis on semispherical-shaped electrolytes. The spatial limitation in the electrolyte/electrode interface leads to local amplification of the electrochemical reaction occurring in the corresponding electrolyte/electrode region. The modified impedance spectroscopy was applied to electrical monitoring of a YSZ ($Y_2O_3$-stabilized $ZrO_2$)/SSC ($Sm_{0.5}Sr_{0.5}CoO_3$) system. The resolved bulk and interfacial component was numerically analyzed in combination with an equivalent circuit model. The effectiveness of the "spreading resistance" concept is validated by analysis of the electrode polarization in the cathode materials of solid oxide fuel cells.

Electrochemical Detection of Hydrogen Peroxide based on Viologen Monolayers (Viologen 박막을 이용한 과산화수소의 전기화학적 검출 특성)

  • Choi, Won-Suk;Lee, Dong-Yun;Park, Sang-Hyun;Park, Jae-Chul;Kwon, Young-Soo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.11
    • /
    • pp.2006-2010
    • /
    • 2008
  • In this paper, we fabricated a biosensor for detecting hydrogen peroxide and investigated the sensing property. We prepared a viologen and hemoglobin modified gold electrode using self-assembly and layer by layer method. The electrochemical property of the viologen derivative was characterized in 0.1 M $NaClO_4$ electrolyte solution by cyclic voltammetry. The modified electrode showed reversible electrochemical properties and high stability. From the results, the viologen can act as a charge transfer mediator for access to the electrode surface. The catalytic characteristics of the designed sensor proved that hemoglobin has been kept in its natural structure and can retain its biological activity. The designed biosensor showed a fast amperometric response, excellent linearity and low detection limit. In addition, it had high sensitivity, good reproducibility and stability.

Pyrocatechol Violet Modified Graphite Pencil Electrode for Flow Injection Amperometric Determination of Sulfide

  • Emir, Gamze;Karakaya, Serkan;Dilgin, Yusuf
    • Journal of Electrochemical Science and Technology
    • /
    • v.11 no.3
    • /
    • pp.248-256
    • /
    • 2020
  • In this study, pyrocatechol violet (Pcv) is proposed for the first time as an efficient electrocatalyst for oxidation of sulfide and flow injection analysis (FIA) of sulfide. A graphite pencil electrode (GPE) was modified with Pcv via immersion of the GPE into 0.01 M Pcv solution for 15 min. Cyclic voltammograms (CVs) demonstrated that Pcv/GPE exhibits a good electrocatalytic performance due to shift in the potential from +400 at bare GPE to +70 mV at Pcv/GPE and obtaining an enhancement in the peak current compared with the bare GPE. A linear range between 0.25 and 250 μM sulfide with a detection limit of 0.07 μM was obtained from the recorded current-time curves in Flow Injection Analysis (FIA) of sulfide. Sulfide in water samples was also successfully determined using the proposed FI amperometric methods.

Photoelectrochemical Deposition of CdZnSe Thin Films on the Se-Modified Au Electrode

  • Ham, Sun-Young;Jeon, So-Yeon;Lee, Ungki;Paeng, Ki-Jung;Myung, No-Seung
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.5
    • /
    • pp.939-942
    • /
    • 2008
  • Photoelectrochemical deposition of CdZnSe thin films on the Se-modified Au electrode using electrochemical quartz crystal microgravimetry (EQCM) and voltammetry is described. Corrosion of pre-deposited Se electrodes by illumination at a fixed potential resulted in $Se^{2-}$ species, which was manifest from the EQCM frequency changes. $Se^{2-}$ species generated from the photocorrosion reacted with $Cd^{2+}$ and $Zn^{2+}$ ions in the electrolyte to form CdZnSe films on the Au electrode. The effect of electrolyte composition on the composition and band gap of CdZnSe films was studied in detail. Also, photoelectrochemistry, EDX, Raman spectroscopy were used for the characterization of CdZnSe thin films.