• 제목/요약/키워드: Mobile Medical Device

검색결과 109건 처리시간 0.031초

상용 제스처 컨트롤러의 근전도 패턴 조합에 따른 인터페이스 연구 (A Research for Interface Based on EMG Pattern Combinations of Commercial Gesture Controller)

  • 김기창;강민성;지창욱;하지우;선동익;쉐강;신규식
    • 공학교육연구
    • /
    • 제19권1호
    • /
    • pp.31-36
    • /
    • 2016
  • These days, ICT-related products are pouring out due to development of mobile technology and increase of smart phones. Among the ICT-related products, wearable devices are being spotlighted with the advent of hyper-connected society. In this paper, a body-attached type wearable device using EMG(electromyography) sensors is studied. The research field of EMG sensors is divided into two parts. One is medical area and another is control device area. This study corresponds to the latter that is a method of transmitting user's manipulation intention to robots, games or computers through the measurement of EMG. We used commercial device MYO developed by Thalmic Labs in Canada and matched up EMG of arm muscles with gesture controller. In the experiment part, first of all, various arm motions for controlling devices are defined. Finally, we drew several distinguishing kinds of motions through analysis of the EMG signals and substituted a joystick with the motions.

사시 진단을 위한 스마트 디바이스 시스템 (Smart Device System for Strabismus Diagnosis)

  • 윤웅배;오지은;문효원;양희경;황정민;박종일;김광기
    • 한국멀티미디어학회논문지
    • /
    • 제19권8호
    • /
    • pp.1538-1543
    • /
    • 2016
  • Strabismus is a non-aligned state;the visual axis of each eye is not directed toward the same direction at the same time. Clinically, the degrees of strabismus are measured by prism cover test, corneal reflex test (Hirschberg test), prism reflex test (Krimsky prism test), But corneal reflex test and prism reflex test is a possibility that errors occur. we suggest a computer-aided diagnosis for strabismus. We made a mobile application to measure angles of strabismus. For 34 patients, we tested our application. The result of comparing between two methods, It showed a difference 7 Prism Diopter(PD). Our application gives strabismus angles just using a camera and a smart device. Therefore, it can reduce the cost and make the diagnosis of strabismus accurate.

간접촬영용 X-선 발생장치 성능 평가 (An ability test for the use of indirect radiographic unit)

  • 임인철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제27권4호
    • /
    • pp.37-41
    • /
    • 2004
  • 목 적 : 측정을 통한 장치의 성능관리 평가로 임상실무에서의 능력배양과 정확한 관전압, 조사시간, 출력선량을 측정하는 기술을 익히고 병원에서 사용 중인 간접촬영용 X-선 발생장치 성능현황을 파악하기 위함이다. 재료 및 방법 : 관전압, 조사시간, 출력선량 측정기를 이용하여 10개 대학병원 간접촬영용 X-선 발생장치(원내,외 각 10대)를 이용하였다. 결 과 : 관전압 정확도 시험 PAE 판정에 의해 부적합한 간접촬영기는 3대가 나왔으며, 조사시간의 정확도 시험에서는 2대, 또한 조사선량의 재현성 시험에서도 조사선량에 대한 변동계수를 계산한 결과 3대가 나왔다. 3가지 성능검사에서 원외(이동차량)의 부적합한 간접촬영기는 5대, 원내는 3대로 원외(이동차량)의 간접촬영기가 원내보다 부적합한 것이 높게 나타났다. 결 론 : 간접촬영기의 성능을 일정하게 유지함으로서 방사선 피폭경감, 화질관리, 재촬영 감소 등에 의해 환자에게 양질의 의료서비스를 제공할 수 있는 여건을 마련할 수 있을 것이다. 따라서 정기적인 성능검사가 필요하다고 사료된다.

  • PDF

WCDMA 휴대전화 전자파가 인공심장 박동기 및 이식형 제세동기에 미치는 영향 (Effects of Radio Frequency Electromagnetic Fields Emitted by WCDMA Mobile Phones on Pacemakers and ICDs)

  • 정재원;최수범;박지수;김덕원
    • 전자공학회논문지
    • /
    • 제52권1호
    • /
    • pp.148-154
    • /
    • 2015
  • 제 2세대 (2G) 휴대전화인 GSM (global system for mobile communication) 휴대전화는 pacemaker 및 ICD (implantable cardioverter defibrillator)의 기능에 영향을 미칠 수 있다고 보고가 되어 왔다. 이에 본 연구에서는 제 3세대 (3G) 휴대전화인 WCDMA (wideband code division multiple access) 휴대전화에서 방출되는 전자파가 pacemaker 및 ICD에 미치는 영향에 대해 알아보았다. 총 5개의 pacemaker 및 3개의 ICD를 대상으로 ECG simulator를 이용한 in-vitro 실험으로 진행하였다. 실제 WCDMA 휴대전화 대신 WCDMA 모듈 (평균 출력 : 0.25 W, 주파수 대역 : 1950 MHz)을 사용했다. WCDMA 모듈 전자파가 pacemaker 및 ICD에 미치는 영향을 평가하기 위해, 각 이식형 의료기기들을 WCDMA 모듈에 최대한 근접 (3 mm 이내) 시킨 후 5분간 전자파에 노출 시켰다. 실험 결과 WCDMA 모듈 전자파가 5개의 pacemaker 및 3개의 ICD에 미친 어떠한 영향도 관찰 할 수 없었다. WCDMA 휴대전화는 GSM 휴대전화보다 더 높은 주파수 대역 (1800-2200 MHz)에서 더 낮은 출력(0.01-0.25 W)을 방출하기 때문에, WCDMA 휴대전화에서 발생하는 전자파는 pacemaker 및 ICD 기기들에게 영향을 미치지 않을 것으로 사료된다.

표면 EMG신호의 상관함수를 이용한 손의 움직임 검출 (Detection of Hand Motions using Cross-correlation of Surface EMG)

  • 이용희;최천호;김순석;김동호
    • 대한의용생체공학회:의공학회지
    • /
    • 제29권3호
    • /
    • pp.205-211
    • /
    • 2008
  • A method of detecting the specific patterns related to hand motions using the surface EMG(electromyogram) on an arm is proposed and tested. To do this, we obtain separately modeling parameters based on the LP, Prony estimator, and calculate the latency shift value between channels by cross-correlation function. Then, the coefficients and latency shift value are applied to the detection method to classify the EMG signals related to hand motions. Compared with the conventional methods, the present method are more useful to detect the motion intention of the user as an input device in the mobile and wearable computing environments. And, We expect that the results of this study are helpful in the development of rehabilitation devices for the handicapped.

유비쿼터스 환경에서 모바일을 이용한 원격 헬스케어 (Mobile Remote Healthcare in Ubiquitous Computing Environments)

  • 강은영;임용순
    • 한국인터넷방송통신학회논문지
    • /
    • 제8권6호
    • /
    • pp.55-61
    • /
    • 2008
  • 본 논문에서는 의학적 센서 모듈과 무선 통신 기술이 결합된 멀티 에이전트 기반 원격 헬스케어 시스템을 제안한다. 제안된 헬스케어 시스템은 멀리 떨어진 곳에서도 환자 모니터링, 의사의 진단과 처방, 환자와 의사, 병원 관계자 사이의 정보 교환 등 폭 넓은 서비스를 지원한다. 또한 Body Area Network(BAN)과 병원의 의사와 관계자들과 연결되며, 이에 대한 유기적이고 병원 서버의 중앙 부하를 감소시키는 확장된 JADE기반 헬스케어 시스템을 디자인하고 개발했다. 에이전트들은 센서로부터 수집된 환자의 정보를 수집, 통합, 전달하고 모바일(PDA)에 표현하기도 한다. 제안된 시스템은 모바일(PDA)과 같은 모바일 디바이스 등을 통하여 섬과 같이 병원과 멀리 떨어진 지역에서도 긴급 상황을 판단하여 원격으로 처리할 수 있다는 장점을 얻게 된다. 또한 환자(노인)의 상태를 실시간으로 모니터링 함으로써 요구되는 시간과 비용을 많이 단축하게 되고, 의료 서비스의 지원에 대한 효율성을 높이게 된다.

  • PDF

The Direction of Neurosurgery to Overcome the Living with COVID-19 Era : The Possibility of Telemedicine in Neurosurgery

  • Min Ho Lee;Seu-Ryang Jang;Tae-Kyu Lee
    • Journal of Korean Neurosurgical Society
    • /
    • 제66권5호
    • /
    • pp.573-581
    • /
    • 2023
  • Objective : Due to the implementation of vaccinations and the development of therapeutic agents, the coronavirus disease 2019 (COVID-19) pandemic that started at the end of 2019 has entered a new phase. As a result, neurosurgeons should reconsider the way they treat their patients. As the COVID-19 situation prolongs, the change in neurosurgical emergency patients according to the number of confirmed cases is no longer clear. Outpatient treatment by telephone was permitted according to government policy. In addition, visits to caregivers in the intensive care unit were limited. Methods : The electronic medical records of patients who had been treated over the phone for a month (during April 2020, while the hospital was closing) were reviewed. Meanwhile, according to the limited visits to the intensive care unit, a video meeting was held with the caregivers. After the video meeting, satisfaction was evaluated using a questionnaire. Results : During April 2020, 1021 patients received non-face-to-face care over the telephone. Among the patients, no critical medical problem occurred due to non-face-to-face care. From July 2021 to December 2021, 321 patients were admitted to the neurosurgical intensive care unit and 107 patients (33.3%) including their caregivers agreed to video visits. Twice a week, advance notice was given that access would be made through a mobile device and the nurse explained to caregivers how to use the mobile device. The time for the video meeting was approximately 20 minutes per patient. Based on the questionnaire, 81 respondents (75.7%) answered that they agreed, and 26 respondents (24.3%) answered that they strongly agreed that was easy to communicate through video meetings. Fifty-two (48.6%) agreed and 55 (51.4%) strongly agreed that they were easy to understand the doctor's explanation. For overall satisfaction with this video meeting, three respondents (2.8%) gave 4/5 points and 95 respondents (88.8%) gave 5/5 points, and nine (8.4%) gave 3/5 points. Their reason was that there was not enough time. Conclusion : In situations where patient visits are limited, video meetings through a mobile device can provide sufficient satisfaction to caregivers. Telemedicine will likely become common in the near future. Health care professionals should prepare and respond to these needs and changes. Therefore, establishing a system with institutional support is necessary.

이동식 BCI 시스템을 위한 싱글보드 시스템의 성능측정 (Performance Measurement of Single-board System for Mobile BCI System)

  • 이효종;김현규;고용빈
    • 전자공학회논문지
    • /
    • 제52권3호
    • /
    • pp.136-144
    • /
    • 2015
  • 뇌파 측정기는 의료용으로 주로 사용되는 유선 장비와 간편하게 사용되는 무선장비로 나뉜다. 이렇게 수집된 뇌파 신호는 신호 처리 시스템에서 목적에 맞게 특징 분석을 하게 된다. 무선 측정기의 경우 사용에 편리성을 제공하지만 실시간 신호 처리를 위한 계산력이 충분한 모바일 시스템이 필요하다. 본 논문에서는 싱글보드 시스템에서 BCI 시스템의 응용을 위한 뇌파신호 처리를 시도하였다. 불행하게도 싱글보드 시스템은 기존 신호 처리 시스템과는 달리 연산 성능이 제한이 되는데 여러 대의 싱글보드 시스템을 이용하여 병렬처리 함으로써 연산 성능의 향상을 시도하였다. 그 결과 뇌파 신호 처리 알고리즘의 연산성능이 초선형으로 증가하는 결과를 얻을 수 있었다.

모바일 RFID를 이용한 U-AD (U-AD using Mobile RFID)

  • 이혜림;한상환;이종서;이찬미;문일영
    • 한국항행학회논문지
    • /
    • 제12권6호
    • /
    • pp.583-590
    • /
    • 2008
  • 모발일 RFID를 이용한 U-AD(Advertisement)는 RFID태그를 읽을 수 있는 리더기를 휴대전화에 장착하여 음반, 도서, 의약품 등에 부착된 Tag의 정보를 휴대전화로 읽어 사용자에게 서비스를 제공할 수 있는 신 개념의 서비스이다. 본 연구에서는 이러한 서비스를 활용하여 휴대폰의 RFID리더기로 Tag를 읽었을 때 단편적으로 밖에 볼 수 없는 광고 내용을 휴대폰으로 실시간으로 볼 수 있는 서비스 시스템을 개발하였다. 모바일 RFID를 이용한 U-AD는 소비자의 휴대폰을 이용하여 해당 상품의 정보를 구체적으로 보여줌으로써 원하는 물건인지 정확하게 알 수 있고 효율적인 구매를 유도할 수 있다. 또한 광고주 측면에서 보면 상품의 광고효과를 극대화하여 더 많은 수요를 창출하게 된다.

  • PDF

이동형 전산화단층촬영장치의 기본 안전 및 필수 성능 기준을 마련하기 위한 연구 (A Study on Establishment of Basic Safety and Essential Performance Criteria of Mobile Computed Tomography)

  • 김은혜;박혜민;김정민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권3호
    • /
    • pp.261-267
    • /
    • 2021
  • As the number of Coronavirus Disease-19 (COVID-19) patients increases in a global pandemic situation, the usefulness of mobile computed tomography (CT) is gaining attention. Currently, mobile CT follows the basic safety and essential performance evaluation criteria of whole-body or limited-view X-ray CT in order to obtain device approval and evaluation in the Republic of Korea. Unlike stationary CT, mobile CT is not operated in shielded areas but rather areas such as intensive care units, operating rooms, or isolation rooms. Therefore, it requires a different basic safety and essential performance evaluation standard than stationary CT. In this study, four derived basic safety evaluation criteria related to electrical, mechanical, and radiation safety were included (dose indication test, protection against stray radiation, safety measures against excessive X-rays, half-value layer measurement); and seven essential performance evaluation criteria were included (tube voltage accuracy, mAs accuracy, radiation dose reproducibility, CT number of water, noise, uniformity, and spatial resolution); total eleven basic safety and essential performance evaluation criteria were selected. This study aims to establish appropriate basic safety and essential performance evaluation criteria for simultaneously obtaining images with diagnostic value and reducing the exposure of nearby patients, medical staff, and radiologic technologists during the use of mobile CT.