Abstract
These days, ICT-related products are pouring out due to development of mobile technology and increase of smart phones. Among the ICT-related products, wearable devices are being spotlighted with the advent of hyper-connected society. In this paper, a body-attached type wearable device using EMG(electromyography) sensors is studied. The research field of EMG sensors is divided into two parts. One is medical area and another is control device area. This study corresponds to the latter that is a method of transmitting user's manipulation intention to robots, games or computers through the measurement of EMG. We used commercial device MYO developed by Thalmic Labs in Canada and matched up EMG of arm muscles with gesture controller. In the experiment part, first of all, various arm motions for controlling devices are defined. Finally, we drew several distinguishing kinds of motions through analysis of the EMG signals and substituted a joystick with the motions.
Keywords
EMG; Commercial gesture controller; Wearable device; HID (Human Interface Device);
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 나연묵.정현태.최재훈 (2013). KEIT PD 이슈리포트 2013-6호 이슈3, 웨어러블 컴퓨터의 현황과 전망, 한국산업기술평가관리원
2 고병우.송원경.김경.이휘영.이승준.박대성 (2012). 뇌졸중 환자의 손 뻗기 동작시 방향에 따른 근활성도 차이. 한국HCI학회 학술대회, 2012(1) : 506-510
3 이정진.김태진.이경민.이응혁 (2013). 근전도를 이용한 상지 인지 재활 훈련 기구에 대한 연구. 한국재활복지공학회 학술대회 논문집 : 83-86
4 강신윤.엄수홍.장문석.이응혁 (2015). 상지 근전도 기반의 로봇 팔 제어방법에 대한 연구. 재활복지공학회논문지, 9(1): 73-80
5 송기선.하동민.엄수홍.이응혁 (2013). 상지 장애인의 IT기기 접근성 향상을 위한 근전도와 가속센서 기반 인터페이스 개발. 한국재활복지공학회 학술대회 논문집 : 150-153
6 정의태 (2014). 근전도 측정을 통한 한 손 동작 입력 방식의 제안. 디지털디자인학연구, 14(1) : 525-532
7 박윤기 (1987). 근전해부학. 학문사