Browse > Article
http://dx.doi.org/10.9717/kmms.2016.19.8.1538

Smart Device System for Strabismus Diagnosis  

Yoon, Woong Bae (Biomedical engineering Branch, National Cancer Center)
Oh, Ji Eun (Biomedical engineering Branch, National Cancer Center)
Moon, Hyo Won (Biomedical engineering Branch, National Cancer Center)
Yang, Hee Kyung (Department of Ophthalmology, Seoul National University Bundang Hospital, Seoul National University College of Medicine)
Hwang, Jeong Min (Department of Ophthalmology, Seoul National University Bundang Hospital, Seoul National University College of Medicine)
Park, Jong Il (Department Of Computer and Software, Hanyang University)
Kim, Kwang Gi (Biomedical engineering Branch, National Cancer Center)
Publication Information
Abstract
Strabismus is a non-aligned state;the visual axis of each eye is not directed toward the same direction at the same time. Clinically, the degrees of strabismus are measured by prism cover test, corneal reflex test (Hirschberg test), prism reflex test (Krimsky prism test), But corneal reflex test and prism reflex test is a possibility that errors occur. we suggest a computer-aided diagnosis for strabismus. We made a mobile application to measure angles of strabismus. For 34 patients, we tested our application. The result of comparing between two methods, It showed a difference 7 Prism Diopter(PD). Our application gives strabismus angles just using a camera and a smart device. Therefore, it can reduce the cost and make the diagnosis of strabismus accurate.
Keywords
Strabismus; Telemedicine; Medical Imaging; Mobile Application; Computer-aided Diagnosis;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 J.D.S. De Almeida, A.C. Silva, A.C. De Paiva, and Teixeira, J.A.M, "Computational Methodology for Automatic Detection of Strabismus in Digital Images through Hirschberg Test," Journal of Computers in biology and medicine, Vol. 42, No. 1, pp. 135-146, 2012.   DOI
2 M.H. Goldbaum, M. Smithline, T.A. Poole, and H.A. Lincoff, "Geometric Analysis of Radial Buckling," American Journal of Ophthalmology, Vol. 79, No. 6, pp. 958-965, 1975.   DOI
3 P. Riddell, L. Hainline, and I. Abramov, "Calibration of the Hirschberg Test in Human Infants," Journal of Investigative Ophthalmology & Visual Science, Vol. 35, No. 2, pp. 538-543, 1994.
4 E. Krimsky, "The Binocular Examination of the Young Child," American Journal of Ophthalmology, Vol. 26, No. 1, pp. 624-625, 1943.
5 Z. Wei, C. Wang, and Y. Nakahira. "Medical Application on Internet of Things," Proceeding of Communication Technology and Application, IET International Conference on IET, 2011.
6 M.K. Jeremy, "Virtual Visits—confronting the Challenges of Telemedicine," New England Journal of Medicine, Vol. 372, No. 18, pp. 1684-1685, 2015.   DOI
7 A. Székely, R. Talanow, and P. Bágyi. "Smartphones, Tablets and Mobile Applications for Radiology," European Journal of Radiology, Vol. 82, No. 5, pp. 829-836, 2013.   DOI
8 D. S. Hirschorn, A.F. Choudhri, G. Shih, and W. Kim. "Use of Mobile Devices for Medical Imaging," Journal of the American College of Radiology, Vol. 11, No. 12, pp. 1277-1285, 2014.   DOI
9 M. McHugh, and D. Lillis. "The Impact of Regulatory Changes on the Development of Mobile Medical Apps," Jouranl of Computing, 4042, 2016.
10 R. Jahns. mHealth App Developer Economics 2015, Technical Report, research2guidance, 2015.
11 The AirStrip OB (R) for wireless fetal heart rate monitoring(2006). http://www.medgadget.com/2006/02/the_airstrip_ob_1.html (accesed Aug.,30, 2016).
12 T.Y. Kim, S.S. Seo, Y.J. Kim, H.K. Yang, J.M. Hwang, and K.G. Kim. "A New Software for Quantitative Measurement of Strabismus based on Digital Image," Journal of Korea Multimedia Society Vol. 15, No. 5, pp. 595-605, 2012.   DOI
13 iOS. http://www.apple.com/ios (accesed Aug., 30, 2016).
14 OpenCV. https://www.oepncv.org (accesed Aug., 30, 2016).
15 OpenGL ES. https://www.khronos.org/opengles (accesed Aug.,30, 2016).