• 제목/요약/키워드: Minimum standards

검색결과 477건 처리시간 0.026초

코어 외 추가 벽체와 기둥 띠철근 간격이 필로티 건물의 내진성능에 미치는 영향 (Effect of Stirrup Spacing of Columns and an Additional Wall other than Core Walls on the Seismic Performance of Piloti-type Buildings)

  • 이수정;김태완
    • 한국지진공학회논문집
    • /
    • 제28권4호
    • /
    • pp.171-181
    • /
    • 2024
  • For low-rise piloti-type buildings that suffered significant damage in the Pohang earthquake, the seismic performance of those designed by codes issued before and after the earthquake has been recently revised. This study started with the expectation that many of the requirements presented in the current codes may be excessive, and among them, the spacing of column stirrup could be relaxed. In particular, the recently revised design code of concrete structures for buildings, KDS 41 20 00, suggests that the column stirrup spacing is 1/2 of the minimum cross-sectional size or 200 mm, which is strengthened compared to KBC 2016, but relaxed than the current KDS, 41 17 00, which is 1/4 of the minimum size or 150 mm. As a result of the study, it was found that the target performance level was sufficiently satisfied by following the current standards and that it could be satisfied even if the relaxed spacing was followed. Therefore, the strict column stirrup spacing of KDS 41 17 00 could be relaxed if a wall other than core walls is recommended in the current guideline for the structural design of piloti-type buildings.

GIS 기반 개발가능지 정형화를 위한 토지형상기준 적용에 관한 연구 (A Study on the Application of Land Form Indices to the Standardization of Development Available Lands, using GIS)

  • 김정훈;채명기;조춘만
    • 한국측량학회지
    • /
    • 제24권1호
    • /
    • pp.99-110
    • /
    • 2006
  • 본 연구는 개발가능지 분석과정에서 부정형 토지에 대한 정형화의 과정에서, 기존에 적용되어 온 작업자의 주관적 판단을 배재하고, GIS기반 토지형상 기준을 마련하여 일련의 개발가능지 정형화과정을 도출하고자 하였다. 구체적으로는, 첫째, 토지형상의 계량화 지표들로서 토지형상지표(LFI, Land For Index) 및 조정된 선형성지표(ARCI, Adjusted Related Circumscribing Circle Index)를 제시하였다. 둘째, 수도권 기존 택지개발(예정)지구들에 대한 사례조사 분석을 통해 표준 최대 및 최소 LFI 및 ARCI 지표값들을 추출하여 표준 토지형상기준 설정에 이용하였다. 셋째, 실제 사례에서 추출된 LFI 및 ARCI 지표값들의 분포를 기반으로 표준영역기준을 설정하고, 실제 토지를 대상으로 LFI 및 ARCI값 관련 토지형상지표 표준영역에서 벗어난 부정형토지들에 대한 개발가능지 정형화과정을 추가로 제안하였다. 본 연구는 실제 개발가능지 사례들을 가지고 다양한 부정형토지들의 객관적인 정형화를 실현하고자, GIS기반 토지형상기준 설정 및 적용을 통한 그 실현가능성을 객관적으로 보여준 데 그 의의가 있겠다.

소화약제 누기 감시장치의 모듈개발 및 성능검증에 관한 연구 (A Study on the Development of a Fire Extinguishing Agent Leakage Monitoring Module and its Performance Assessment)

  • 손봉세;홍성호;고아라
    • 한국화재소방학회논문지
    • /
    • 제30권2호
    • /
    • pp.43-48
    • /
    • 2016
  • 가스계소화설비는 소화약제의 자연 누기와 소화설비 노후로 인한 누기 등으로 화재진압 능력이 저하되는 문제점이 발생하고 있다. 이에 본 연구에서는 소화약제의 누기를 실시간으로 감지하는 압력누기 체크센서 모듈을 개발하였으며, 개발 모듈에 대한 성능평가를 하였다. 국내 외적으로 압력누기 감시 시스템에 대한 명확한 시험기준이 마련되어 있지 않다. 따라서 국외 유사 기준 ISO 7240, FM 1421와 국내 수신기 형식승인 및 제품검사의 기술기준을 참고하여 개발 모듈에 맞게 기본 성능과 내환경성에 대한 기준을 마련하고 평가를 실행하였다. 기본 성능 평가는 압축공기를 모듈에 인가하는 방식으로 최저작동 압력이 0.3 bar인 것을 확인하였다. 내환경성 검증은 통상적으로 발생할 수 있는 기후변화에도 오작동 없이 정상적으로 작동하는지를 확인하였다. 그 결과, 고온($50^{\circ}C$) 및 저온($-10^{\circ}C$) 환경 기준에서 이상 없이 정상 작동하였다.

마이크로파 X-밴드에서의 종단 개방 동축선 센서를 이용한 금속표면균열의 비접촉 검출 연구 (Study on Non-contact Detection of Surface Cracks of the Metals Using an Open-Ended Coaxial Line Sensor at X-band)

  • 양승환;김동석;김기복;김종헌;강진섭
    • 비파괴검사학회지
    • /
    • 제32권2호
    • /
    • pp.192-197
    • /
    • 2012
  • 본 연구는 금속의 표면균열 검출을 위해 마이크로파를 이용한 비파괴측정에 관한 것이다. X-band 대역인 11 GHz 주파수와 종단 개방 동축선 센서를 이용하여 금속 표면에 주사된 마이크로파의 반사계수를 측정하여 균열 여부 및 균열의 폭을 판단하게 된다. 또한 반사계수의 최대값과 최소값의 차이를 매개변수(K)로 하여 균열의 깊이를 평가하였는데 K값과 균열의 깊이는 선형 관계를 보였다. 따라서 본 연구는 종단 개방 동축선 센서를 이용한 비접촉식 금속표면균열 평가의 가능성을 보여주었다.

소형 샤르피 충격시험편을 이용한 1Cr-1Mo-0.25V강의 천이온도 평가 (Transition Temperature Evaluation of 1Cr-1Mo-0.25V Steel Using Miniaturized Charpy Impact Specimen)

  • 남승훈;김시천;이해무
    • 한국가스학회지
    • /
    • 제2권4호
    • /
    • pp.42-46
    • /
    • 1998
  • 소형 시험편 기술은 최소량의 재료를 사용하여 그 재료의 물리적인 거동을 특성화할 수 있기 때문에 산업설비로부터 많은 재료를 수집할 수 없는 경우에 유용한 방법이다. 본 연구에서 사용한 재료는 화력발전소 터빈로터 소재로 많이 사용되고 있는 1Cr-1Mo-0.25V강이었으며, $^630{\circ}C$에서 등온열화처리하여 5종류의 가속 열화 모사재를 만들었다. 충격시험에는 표준 시험편과 소형 시험편이 사용되었으며, 일부 소형 시험편에 소성 구속을 증가시키기 위해 측면흠을 만들어 넣었다. 표준 시험편과 소형 시험편의 충격특성을 비교하였으며 크기효과를 고찰하였고, 소형 시험편의 연성취성천이온도와 표준 시험편의 연성취성천이온도와의 상관관계를 만들었다. 따라서 소형 시험편의 충격시험결과로부터 표준 시험편의 충격특성을 추정하는 것이 가능하게 되었다.

  • PDF

항공교통관제사의 피로위험관리시스템 도입에 따른 국내 적용 방안 (Domestic Application Plan of Fatigue Risk Management System by Air Traffic Controller)

  • 이영종
    • 한국항행학회논문지
    • /
    • 제23권6호
    • /
    • pp.501-506
    • /
    • 2019
  • 본 논문은 국제민간항공기구(ICAO) 국제기준에 부합하기 위하여 항공교통관제사에 대한 피로위험관리시스템(FRMS)의 도입 및 시행을 앞두고 과학 데이터 기반에 근거하여 우리에 적합한 FRMS 구축을 위한 규범적 대안을 제시하고자 한다. 따라서 현행 국내운영기준에 대하여 항공관제기관별 운영을 확인하고, 해외 각국의 항공교통관제 기관별 운영 방식과 기준을 비교·검토하였다. 우리나라의 관제사는 주/야 최대 근무시간 10시간, 최소휴식 8시간, 주 40시간으로 규정하고 있다. 현재 항공교통관제기관의 경우의 주간의 경우는 기준시간과 적합한 근무를 하나, 야간의 경우는 평균적으로 5.9시간을 초과한다. 그리고 주 40시간 경우 평균적 15.7시간의 초과근무를 하고 있다. 이러한 야간 근무시간 조정 방법으로 인원보충에 의한 적절한 야간 근무시간 배분과 더불어 근무교대 방식이 1일 2교대(주/야) 방법이 아닌 개인 schedule에 따른 근무자 투입 방식의 형태를 다양하게 함으로써 이를 해결하여 나갈 수 있을 것을 제안하고자 한다.

Visibility Evaluation for Agricultural Tractor Operators According to ISO 5006 and 5721-1 Standards

  • Kabir, Md. Shaha Nur;Song, Mingzhang;Chung, Sun-Ok;Kim, Yong-Joo;Kim, Su-Chul;Ha, Jong-Kyou
    • Journal of Biosystems Engineering
    • /
    • 제40권1호
    • /
    • pp.19-27
    • /
    • 2015
  • Purpose: A system to measure the visibility of agricultural tractor operators was designed and evaluated according to ISO standards, and a blind area diagram around the tested tractor was created based on the manual method recommended by the National Institute for Occupational Safety and Health (NIOSH). Methods: A visibility measurement system was designed and evaluated based on the ISO 5006 and ISO 5721-1 standards. Two bulbs used to simulate the operator's eyes were mounted on a bar with a supporting frame. A wooden frame was used to determine the seat index point position. The 12-m visibility test circle was divided into six sectors of vision, and the test tractor was placed at the center of the circle. Artificial light was supplied in the darkened environment, and shadow or masking effects were measured manually around the 12-m circle. Results: When the bulbs were placed at the operator's eye level, front visibility was good; no masking was found in the "A" vision sector, but larger masking widths were found in the "B" and "C" vision sectors. Since the masking width exceeded 700 mm, additional tests, such as movement of the light sources to both sides of the operator's eye level, were performed. Less than six masking effects were found in the semi-circle of vision to the front, and more than one masking was found in the "B" and "C" visual fields. The minimum distance between the centers of two masking effects exceeded 2500 mm when measured as a chord on the semi-circle of vision. A blind area diagram was created to define the exact nature of the blind spots and mirror visibility. Conclusions: Visibility evaluation is an effective way to enable proper and safe operation for agricultural tractor operators. Inclusion of this visibility evaluation test in the general testing process might aid tractor manufacturers.

Moisture Absorption and Desorption Properties of Douglas Fir, Hinoki, Larch, Plywood, and WML Board in Response to Humidity Variation

  • PARK, Hee-Jun;JO, Seok-Un
    • Journal of the Korean Wood Science and Technology
    • /
    • 제48권4호
    • /
    • pp.488-502
    • /
    • 2020
  • In this study, the moisture absorption and desorption properties presented by the Health-Friendly Housing Construction Standards of South Korea were compared using the wood of three tree species (Douglas-fir, Hinoki, Larch) and two types of wood-based materials(Plywood, WML Board). The national standards for functional building materials present that the amounts of moisture absorption and desorption should be at least 65g/㎡ on average, respectively according to the test method under KS F 2611:2009. Therefore, in this study, the moisture absorption/desorption properties of materials with no treatment (Control), with punching, and with surface stain finishing and the moisture absorption/desorption property improvement effects of the treatments were compared and analyzed. According to the results of this study, it was evaluated that all five types of wood and wood-based materials tested did not satisfy the amount of moisture absorption/desorption of at least 65g/㎡, which is the performance standard for moisture absorption/desorption functional building materials, indicating that untreated wood and wood-based materials cannot be applied as functional finishing materials according to the Health-Friendly Housing Construction Standards. The surface stain finishing greatly reduced the moisture absorption and desorption rates of the materials, and the amounts of moisture absorbed and desorbed were also shown to decrease by at least two times on average. When the surfaces of the materials were punched with Ø4mm holes at intervals of 20 mm, the moisture absorption/desorption areas increased from 18% to 51%, and this increase was shown to be capable of increasing the amounts of moisture absorbed/desorbed by 29% on average at the minimum, and 81% on average at the maximum. The effects of punching were shown to be identical even in cases where the materials were stain finished. For the application of wood or wood-based materials as eco-friendly, health-friendly, and moisture absorption/desorption functional building materials hereafter, it is judged that new physical and chemical improvement studies should be conducted, and treatment methods should be developed.

국내 시판 고령친화식품의 품질특성 (Quality Characteristics of Domestic Commercial Senior-friendly Foods)

  • 장미순;김풍호;오재영;박선영;김예율;강상인;김진수
    • 한국수산과학회지
    • /
    • 제54권3호
    • /
    • pp.251-260
    • /
    • 2021
  • As the aging population of the world grows, senior-friendly foods are becoming increasingly popular. In this study, the quality characteristics of domestic commercial senior-friendly foods were investigated and compared to the standard specifications of the Food Code and KS H4897. Herein, 18 samples of domestic commercial senior-friendly foods were utilized to analyze their appearance, physical properties (hardness and viscosity), nutritional value (protein, vitamin, mineral and dietary fiber), digestion rate, and hygiene indicator bacteria. When compared to the hardness standards of the Food Code all 18 samples were found to be satisfactory; however, when compared to the nutritional standard (at least three types of nutrients must be above the minimum), only five products, HG-7, DW-1, PS-1, OH-1 and OH-2, were found to be satisfactory. In addition, when the 18 samples were compared to the Korean Industrial Standard (2020), all 18 products were found to be satisfactory for physical properties and hygiene standards; furthermore, all samples, excluding HB-2, were suitable for nutritional standards (at least one type of nutrient must be above the standard).

디지털 트윈국토 건물 데이터 품질 표준 개발을 위한 항목 도출에 관한 연구 (A Study on the Derivation of Items for Development of Data Quality Standard for 3D Building Data in National Digital Twin)

  • 김병선;이희석;홍상기
    • 지적과 국토정보
    • /
    • 제52권1호
    • /
    • pp.37-55
    • /
    • 2022
  • 본 연구는 디지털 트윈국토 건물 데이터 품질 표준을 개발하기 위한 품질 항목 모델을 제시하는데 목적이 있다. 이를 위해 3차원 공간정보 오류의 특징과 품질 표준 필요성에 대해 도출하였으며, 디지털 트윈국토 건물 품질 개발에 필요한 데이터 모델 표준과 공간정보 품질 표준에 대해 분석하였다. 이러한 내용을 토대로 디지털 트윈국토 건물 데이터의 품질 평가 범위, 품질 표준 확장 요소(기하 무결성, 기하 충실도, 위치 정확성, 시맨틱 분류 정확성) 및 품질 항목 모델(안)을 제시하였다. 본 연구에서 제안한 디지털 트윈국토 건물 품질 항목모델은 디지털 트윈국토 품질 표준 개발은 물론 이와 관련된 다양한 디지털 트윈국토 공간정보표준 개발에 기여할 것으로 판단된다.