• 제목/요약/키워드: Microsphere

검색결과 221건 처리시간 0.02초

Au@TiO2 코어쉘 미세 입자의 합성 및 특성 평가 (Synthesis and Characterization of Au@TiO2 Core-Shell Microspheres)

  • 김순금;장하준;장재원;심재현;백성준
    • 한국전기전자재료학회논문지
    • /
    • 제35권4호
    • /
    • pp.392-397
    • /
    • 2022
  • We present the structural and optical properties of Au@TiO2 core-shell microsphere structure prepared by a hydrothermal synthesis method. As a way to improve the efficiency of organic solar cells, the Au@TiO2 core-shell microsphere was synthesized to use the local surface plasmon resonance (LSPR) phenomenon. The synthesized results were confirmed to have the Au@TiO2 core-shell structure using a high-resolution transmission electron microscopy. An absorption was observed to occur at 527 nm belonging to the visible light region using a visible light spectroscopy, which supports the LSPR phenomenon. We suggest that the Au@TiO2 core-shell microsphere is highly likely to be applied to organic solar cells including dye-sensitized solar cells. In addition, we expect it to be widely used not only in the energy but also in the bio as well as in the environmental fields.

Silk Fibroin Microsphere and Its Characterization

  • Yeo, Joo-Hong;Lee, Kwang-Gill;Lee, Yong-Woo;Kweon, Hae-Yong;Woo, Soon-Ok
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • 제6권2호
    • /
    • pp.151-155
    • /
    • 2003
  • Using gel filtration chromatography, high molecular silk fibroin with high purity was obtained and silk flbroin microsphere particles (SFMP) could be simply made by spray dryer method. Also, some of the physicochemical properties of SFMP and morphology were investigated. The average molecular weight of pure silk fibroin protein dissolved in calcium chloride is about 61,500g/㏖ as measured by gel permeation chromatography. SFMP was spherical in shape, and particles, sized average of 2 ${\pm}$ 10 ${\mu}$, were observed by SEM and particle analyzer, respectively. Obtaining microspheres particles by spray dryer method accelerated the transition from the random coil to the $\beta$-sheet structure during spray dryer treatment. It was identified by the basic fourier transform infrared spectroscopy of SFMP. The swelling ratio of SFMP is majorly dependent on the pH of the solution, not on the occurred gelation. The characteristic structure, which might be applicable to immobilization of drugs is superior to other matrix materials for the use of biomaterials with skin affinity.

생분해성 iodophor microsphere 함유 유두침지 소독제의 건유기 젖소에서의 유방내 신규감염 예방 효과 (Effects of teat dipping disinfectant containing biodegradable iodophor microspheres on preventing dry period intramammary infection in dairy cows)

  • 황철용;김종민;윤화영;한박;한홍율
    • 대한수의학회지
    • /
    • 제44권1호
    • /
    • pp.113-120
    • /
    • 2004
  • 1% iodophor loaded microspheres of PLGA (Poly[DL-Lactide-co-Glycolide]) were prepared by solvent evaporation method and were applied to the cows on dry period for evaluating it's preventive effects on intramammary infections. The morphology of the microspheres were evaluated using scanning electron microscopy and their releasing patterns were investigated. On investigating idophor releasing patterns of the microsphere, burst releasing pattern was detected until 2 days after in vitro incubation and sustained releasing was observed until 4 weeks. In field trial of teat dipping solution containing idophor loaded microspheres in dry cows showed significant preventive effects of intramammary infection caused by S. aureus, S. agalactiae, coagulase negative Staphylococci and coliform bacteria (p<0.05).

Tc-99m 거대응집알부민을 이용한 폐관류 스캔에서 관찰되는 다발성 열소 (Hot Spots on Tc-99m MAA Perfusion Lung Scan)

  • 임석태;손명희
    • 대한핵의학회지
    • /
    • 제35권4호
    • /
    • pp.288-290
    • /
    • 2001
  • A 61 year-old woman underwent perfusion and inhalation lung scan for the evaluation of pulmonary thromboembolism. Tc-99m MAA perfusion lung scan showed multiple round hot spots in both lung fields. Tc-99m DTPA aerosol inhalation lung scan and chest radiography taken at the same time showed normal findings (Fig. 1, 2). A repeated perfusion lung scan taken 24 hours later demonstrated no abnormalities (Fig. 3). Hot spots on perfusion lung scan can be caused by microsphere clumping due to faulty injection technique or by radioactive embolization from upper extremity thrombophlebitis after injection. Focal hot spots can signify zones of atelectasis, where the hot spots probably represent a failure of hypoxic vasoconstriction. Artifactual hot spots due to microsphere clumping usually appear to be round and in peripheral location, and the lesions due to a loss of hypoxic vasoconstriction usually appear to be hot uptakes having linear $borders^{1-3)}$. Although these artifactual hot spots have been well-known, we rarely encounter them. This report presents a case with artifactual hot spots due to microsphere clumping on Tc-99m MAA perfusion lung scan.

  • PDF

고분자 혼합법과 다중 에멀젼법에 의해 제조된 생분해성 미립구로부터 펩타이드의 용출에 관한 연구 (Release Profile of Peptide from Biodegradable Microspheres: Comparison of Blending and Multiple Emulsion Method)

  • 정구영;김중권;박목순;명평근
    • Journal of Pharmaceutical Investigation
    • /
    • 제36권4호
    • /
    • pp.245-251
    • /
    • 2006
  • The novel microsphere blending and multiple emulsion method by single process was tried to prepare sustained release microspheres which release a physiologically active substance for long periods of time. A drug was separately dissolved in each of two or more oils containing biodegradable polymers to give the primary oil phases. The primary oil phases were dispersed in single aqueous phase in succession. From the drug-dispersed solution, the organic solvent was removed to produce microspheres. The accelerated drug release from the microsphere formulation prepared by single process through the multiple emulsion method was very similar to a physical blending of separately prepared microspheres using the same polymers. But long term release was not same. In this study, leuprorelin acetate loaded poly(lactide-co-glycolide) microsphere formulation for one-month delivery was developed by the multi-emulsion method followed by solvent extraction/evaporation method.

FAHM(Fly-Ash Hollow Microsphere)첨가에 의한 도자기의 소성특성과 경량화 (Lightweight Characteristics and Sintering behavior of Porcelain by Addition FAHM(Fly-Ash Hollow Microsphere))

  • 김근희;피재환;김종영;조우석;김경자
    • 한국세라믹학회지
    • /
    • 제48권3호
    • /
    • pp.228-235
    • /
    • 2011
  • Sintering behavior and lightweight characteristics of porcelain by addition of FAHM (Fly-Ash Hollow Microsphere) were evaluated. Green body of Backja composition (general porcelain) in which FAHM was added(15 and 20 wt%) was made by slip casting method. The green body was sintered at 1270 and $1290^{\circ}C$ and maintained for 1h. The bulk density and linear shrinkage of the sintered body with FAHM (20 wt%) decreased. As the contents of FAHM. increased, mullite and cristobalite phases increased. In the microstructure, FAHM shells remained after sintering, and the generation of mullite fibers around FAHM shells also were confirmed. the weight of porcelain with of 20% FAHM decreased by 40% and residual FAHM shells promoted the mullite of generation in the matrix.

Alginate-enclosed Microspheres를 이용한 배당체 합성에 관한 연구 (A Study on Glycoside Synthesis Using Alginate-enclosed Microspheres)

  • 김해성;김우식
    • KSBB Journal
    • /
    • 제8권4호
    • /
    • pp.320-327
    • /
    • 1993
  • 스티렌/아크렬 라텍스 폴리머를 폴리에릴렌이민으 로 표면처 리하여 얻은 PEI-microspheres는 그 표면 화학적 특성이 효소의 고정화에 적합하여 배당체의 합성반응에 서 필요로 하는 alginate-enclosed micro­s spheres biocatalyst를 제조할 수 있었고 라텍스 폴리머 표변에 형성된 폴리에틸렌이민 피막은 효소 부근에 친수성 분위기를 유지하여 높은 효소활성을 나 타내었을 뿐만 아니라, 생성된 배당체가 효소에 접 근하여 가수분해되는 반응을 억제하여 배당체의 수 율과 농도를 크게 증가시 켰으므로 alginate-en closed microspheres에 의한 배당체의 합성반응이 연속생산공정으로 연구개발 될 수 있다.

  • PDF

PLGA 미립구로부터 PLGylated G-CSF의 서방성 방출 (Sustained Release of PLGylated G-CSF from PLGA Microsphere)

  • 정경환;임형권;이시욱;강관엽;박태관
    • KSBB Journal
    • /
    • 제17권1호
    • /
    • pp.33-37
    • /
    • 2002
  • PLGA 미립구로부터 G-CSF의 방출 거동 양상을 향상 시키기 위하여 G-CSF를 분자량 5000인 methoxy polyethylene glycol-aldehyde로 PEGylation 시켰다. 대부분의 G-CSF는 mono-PEGylation 되었으며, 이를 SDS-PAGE, HPLC, 및 펩타이드 지도 분석을 통해 확인하였다. W/O/W 방법을 사용하여 G-CSF 및 PEGylated G-CSF의 PLGA 미립구를 제조하였으며, 이때 봉입율은 높은 상태였다. 미립구내로 더 많은 G-CSF를 봉입하기 위하여 액상의 G-CSF 및 PEGylated G-CSF을 농축하였고 native gel과 gel filtration 크로마토 그래피를 통하여 단백질이 안정함을 확인하였다. 이렇게 제조한 PLGA 봉입체의 in vitro 방출 거동을 조사한 결과 PEGylated G-CSF는 native G-CSF에 비하여 더 오랜 시간 동안 방출이 지속되었고 최대 방출량도 증가하였다.

Preparation of Affinity Column Based on ZR4+ Ion forPhosphoproteins Isolation

  • Lee, Seon-Mi;Bae, In-Ae;Park, Jung-Hyen;Kim, Tae-Dong;Choi, Seong-Ho
    • 대한화학회지
    • /
    • 제53권3호
    • /
    • pp.279-285
    • /
    • 2009
  • This paper has described about preparation of $Zr^{4+}$ affinity column based on the poly(styrene-co- gly-cidyl methacrylate) prepared by emulsion polymerization of styrene and glycidyl methacrylate in order to isolate phosphopeptide. The $Zr^{4+}$ ions were introduced after the phophonation of an epoxy group on polymeric microspheres. The successful preparation of $Zr^{4+}$-immobilized polymeric microsphere stationary phase was confirmed through Fourier transform infrared spectra, optical microscopy, scanning electron microscopy, X-ray photoelectron spectra and inductively coupled plasma-atomic emission spectrometer. The separation efficiency for $Zr^{4+}$ affinity column prepared by slurry packing was tested to phosphonated casein and dephosphonated casein. The resolution time (min) of the phosphonated casein was higher than that of dephosphated casein for $Zr^{4+}$ affinity polymeric microsphere by liquid chromatography. This $Zr^{4+}$ affinity column can be used for isolation of phosphonated casein from casein using liquid chromatography.

Prenatal effect of pyrantel pamoate on several hematological parameter of offspring in mice

  • Abdulwahab.A.Noorwall;Ghazi M. Al-Hachim;Award -Omar
    • Archives of Pharmacal Research
    • /
    • 제9권2호
    • /
    • pp.87-91
    • /
    • 1986
  • In attempt to develop a drug delivery system using serum albumin microspheres, bovine serum albumin microspheres containing antitumar agent. Cytarabine, were prepared. The shape, surface characteristics, size distribution, behavior of in vivo distribution, drug release behavior, and degradation of albumin microsphers in animal liver issue homogenate and proteolytic enzyme were investigated. The shape of albumin microspheres was spherical and the surface was smooth and compact. The size distribution of the albumin microspheres was effected by dispertion forces during emulsification and albumin concentration. Distribution of albumin microspheres after imtravenous administration in rabbit was achieved immediately. In vitro, albumin microsphere matrix was so hard that it retained most of cytarabine except initial burst during the first 10 minutes, and the level of drug release during the initial burst was affected by heating temperature, drug/albumin microsphere matrix was so hard that it retained most of cytarabine except initial burst during the first 10 minutes, and the level of drug release during the initial burst was affected by heating temperature, drug/albumin concentration ratio and size distribution. After drug release test, the morphology of albumin microspheres was not changed. Albumin microsphere matrix was degraded by the animal liver issue homogenate and proteolytic enzyme. The degree of degradation was affected by heating temperature.

  • PDF