• 제목/요약/키워드: Micro-channel chip

검색결과 74건 처리시간 0.035초

3 차원 마이크로 채널에서 나선지수에 의한 혼합예측 (The Prediction of mixing with Helix Index for 3-Dimensional channel in micro)

  • 정승훈;맹주성
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2460-2464
    • /
    • 2008
  • The present paper suggests new method to know the effects of molecular diffusion and the helicity of microchannel flows on mixing in passive micromixers, which are essential components of a microfluidic chip. In this study, 'Helix Index' is newly defined as the magnitude of chaotic advection. Relationship between Helix Index and Mixing Index is analyzed numerically such as the wide range of Peclet and Reynolds numbers in three dimensional serpentine microchannel when using soluble solutions (water/glycerol). As a result, a simple algebraic equation is derived by this relationship based on a regression analysis. The algebraic equation is found to be able to accurately predict the mixing performance without solving the coupled, complex momentum and mass transfer equations.

  • PDF

마이크로 광 조형기술을 이용한 3차원의 배리어가 포함된 케닉스 마이크로 믹서의 개발 (Development of a Three-Dimensional Barrier Embedded Kenics Micromixer by Means of a Micro-Stereolithography Technology)

  • 이인환;권태헌;조동우;김동성
    • 대한기계학회논문집A
    • /
    • 제29권6호
    • /
    • pp.904-912
    • /
    • 2005
  • The flow in a microchannel is usually characterized as a low Reynolds number (Re) so that good mixing is quite difficult to be achieved. In this regard, we developed a novel chaotic micromixer, named Barrier Embedded Kenics Micromixer (BEKM). In the BEKM, the higher level of chaotic mixing can be achieved by combining two general chaotic mixing mechanisms: (i) splitting/reorientation by helical elements inside the microchannel and (ii) stretching/folding via periodically located barriers on the channel wall. The fully three-dimensional geometry of BEKM was realized by a micro-stereolithography technology, in this study, along with a Kenics micromixer and a circular T-pipe. Mixing performances of three micromixers were experimentally characterized in terms of an average mixing color intensity of phenolphthalein. Experimental results show that BEKM has better mixing performance than other two micromixers. Chaotic mixing mechanism, proposed in this study, could be integrated as a mixing component with Micro-Total-Analysis-System, Lab-on-a-chip and so on.

AMBA Platform을 기반으로 하는 SoC 상의 DMAC 설계 (Implementation of DMAC on SoC based on AMBA Platform)

  • 황인기;김정식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.417-419
    • /
    • 2004
  • Because of the demands for high performance and high integrated system, the needs for optimal platform becomes more importance. Optimal platform can handle more data effectively with same resources. AMBA(Advanced Microprocessor Bus Architecture)$^{TM}$ defines on-chip communication standard for designing high performance embedded micro-controllers. It is consisted of AHB, ASB and APB. It can support fast implementation and reliability in system that is composed with reusable IPs. DMAC is one of master in system and generate master signals of AHB to communicate data from one slave(peripheral or memory) to another slave. It can reduce burden of CPU and increase system performance. We designed DMAC based on AMBA and it supports 13 Channels. Each channel can be controlled by software program. It decides channel's priority using round-robin method. It can support P2P, P2M, M2P and P2P communication.

  • PDF

마이크로 혼합기와 반응기로 구성된 DNA 결찰용 바이오칩에 관한 연구 (A Study About Biochip Combined with Micro Mixer and Reactor for DNA Ligation)

  • 강도형;안유민;황승용
    • 대한기계학회논문집A
    • /
    • 제32권8호
    • /
    • pp.624-632
    • /
    • 2008
  • In this research, we developed new PDMS-glass based microbiochip consisted of the micromixer and microreactor for DNA ligation. The micromixer was composed of a straight channel integrated with nozzles and pillars, and the microreactor was composed of a serpentine channel. We coated the PDMS chip surface with the 0.25wt.% PVP solution to prevent the bubble generation which was caused by the hydrophobicity of the PDMS. The new micomixer was passive type and the mixing was enhanced by a convective diffusion using the nozzle and pillar. The 10.33mm long micromixer showed the good mixing efficiency of 87.7% at 500 l/min flow rate. We could perform the DNA ligation successfully in the microbiochip, and the ligation time was shortened from 4 hours in conventional laboratory method to 5 min in the microbiochip.

모빌 로보트의 초음파 센서열에 관한 연구 (A Study on the Ultrasonic Sensor Array for the Mobile Robot)

  • 윤영배;이상민;최홍호;홍승홍
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 전기.전자공학 학술대회 논문집(II)
    • /
    • pp.1256-1259
    • /
    • 1987
  • This paper gives a new SRF (Sonic Range Finder) Array formation on the mobile robot. This SRF Array formation obtaine the mobile robot's environmental informations wider and faster than the other systems and detects the obstacles in the robot's path. It is processed and controlled by 8031, on-chip micro-computer. SRF Array sensors are drived by the LM1812 transceiver and selected by the 8-channel channel multiplexer. In this paper, it detects the obstacles in wider range and gives them to the MAIN to design the shortest modify path.

  • PDF

워터젯을 이용한 블라스팅 유리 마이크로 채널의 표면거칠기 개선 (Surface Smoothing of Blasted Glass Micro-Channels Using Abrasive Waterjet)

  • 손성균;한솔이;성인하;김욱배
    • 대한기계학회논문집B
    • /
    • 제37권12호
    • /
    • pp.1159-1165
    • /
    • 2013
  • 파우더 블라스팅은 미세 유리가공법으로서 가공속도가 빠르고 저비용의 장점이 있지만 유리를 취성파괴 시키기 때문에 표면거칠기가 좋지않다. 블라스팅된 표면에 저압의 워터젯을 분사하여 표면에서의 연마 슬러리의 흐름을 통해 표면거칠기를 저감할 수 있다. 본 연구에서는 소다라임 유리에 블라스팅으로 마이크로 채널을 가공한 후 워터젯을 연속 적용하고, 마이크로 채널의 표면거칠기 및 단면 형상의 변화의 과정을 관찰하였다. 워터젯의 적용결과, 초기단계에서는 블라스팅에 의한 미세 요철이 제거되었고, 이후 표면하부의 크랙이 제거되어 평균 표면거칠기 50 nm 근방의 매끈한 표면을 얻을 수 있었다. 표면거칠기 저감에 동반하여 채널단면의 확장 과정도 함께 관측하였다. 마지막으로 제안한 방법에 의해 미세유체칩의 가공 결과를 제시하였다.

Analysis of Downlink Wideband DS-CDMA Systems with Smart Antenna for Different Spreading Bandwidths in Wideband Multipath Channel

  • Jeon Jun-Soo;Kim Cheol-Sung
    • Journal of electromagnetic engineering and science
    • /
    • 제4권4호
    • /
    • pp.183-189
    • /
    • 2004
  • In this paper, the Eigen-RAKE receiver in wideband direct sequence code-division multiple access(DS-CDMA) systems with downlink smart antenna is analyzed for different spreading bandwidths(1.25 MHz, 5 MHz, 10 MHz) and different channel environments(macro, micro). The realistic spatio-temporal wideband multipath channel is assumed, one of which is standardized multiple-input single-output(MISO) radio channel model for WCDMA link-level simulations proposed by $3^{rd}$ generation partnership project(3GPP) contributions. We assumed spatial scattering phenomenon in which many unresolvable path signals within a limited range of spatial angle simultaneously contribute to the signals received at the receiver. Several multipaths within one chip are distinguished into each one and the first multipath components are selected as the desired signal and the others are considered self-interference. Downlink DS-CDMA system with eigenbeamformer using wider bandwidth present better performance than that using narrow bandwidth system by employing Eigen-RAKE receiver of many number of branches. It is shown that the downlink eigenbeamformer is more effective in typical urban macro cellular environments when using Eigen-RAKE receiver.

Feasibility of On-chip Detection of Endotoxin by LAL Test

  • Lee, Eun-Kyu;Suh, Chang-Woo;Hwang, Sang-Youn;Park, Hyo-Jin;Seong, Gi-Hoon;Ahn, Yoo-Min;Kim, Yang-Sun
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제9권2호
    • /
    • pp.132-136
    • /
    • 2004
  • The LAL (Limulus amebocyte lysate) test for the detection and quantification of endotoxin is based on the gelation reaction between endotoxin and LAL from a blood extract of Limulus polyphemus. The test is labor intensive, requiring dedicated personnel, a relatively long reaction time (approximately 1 h), relatively large volumes of samples and reagents and the detection of the end-point is rather subjective. To solve these problems, a miniaturized LOC (lab-on-a-chip) prototype, 62mm (L) ${\times}$ 18 mm (W), was fabricated using PDMS (polydimethylsiloxane) bonded to glass. Using this prototype, in which 2mm (W) ${\times}$ 44.3mm (L) ${\times}$ 100 $\mu\textrm{m}$ (D) microfluidic channel was constructed, turbidometric and chromogenic assay detection methods were compared, and the chromogenic method was found the most suitable for a small volume assay. In this assay, the kinetic-point method was more accurate than the end-point method. The PDMS chip thickness was found to be minimized to around 2 mm to allow sufficient light transmittance, which necessitated the use of a glass slide bonding for chip rigidity. Due to this miniaturization, the test time was reduced from 1 h to less than 10 min, and the sample volume could be reduced from 100 to ca. 4.4 ${\mu}$L. In summation, this study suggested that the LOC using the LAL test principle could be an alternative as a semi-automated and reliable method for the detection of endotoxin.

Development of Microfluidic Radioimmunoassay Platform for High-throughput Analysis with Reduced Radioactive Waste

  • Jin-Hee Kim;So-Young Lee;Seung-Kon Lee
    • 대한방사성의약품학회지
    • /
    • 제8권2호
    • /
    • pp.95-101
    • /
    • 2022
  • Microfluidic radioimmunoassay (RIA) platform called µ-RIA spends less reagent and shorter reaction time for the analysis compared to the conventional tube-based radioimmunoassay. This study reported the design of µ-RIA chips optimized for the gamma counter which could measure the small samples of radioactive materials automatically. Compared with the previous study, the µ-RIA chips developed in this study were designed to be compatible with conventional RIA test tubes. And, the automatic gamma counter could detect radioactivity from the 125I labeled anti-PSA attached to the chips. Effects of the multi-layer microchannels and two-phase flow in the µ-RIA chips were investigated in this study. The measured radioactivity from the 125I labeled anti-PSA was linearly proportional to the number of stacked chips, representing that the radioactivity in µ-RIA platform could be amplified by designing the chips with multi-layers. In addition, we designed µ-RIA chip to generate liquid-gas plug flow inside the microfluidic channel. The plug flow can promote binding of the biomolecules onto the microfluidic channel surface with recirculation in the liquid phase. The ratio of liquid slug and air slug length was 1 : 1 when the 125I labeled anti-PSA and the air were injected at 1 and 35 µL/min, respectively, exhibiting 1.6 times higher biomolecule attachment compared to the microfluidic chip without the air injection. This experimental result indicated that the biomolecular reaction was improved by generating liquid-gas slugs inside the microfluidic channel. In this study, we presented a novel µ-RIA chips that is compatible with the conventional gamma counter with automated sampler. Therefore, high-throughput radioimmunoassay can be carried out by the automatic measurement of radioactivity with reduced radiowaste generation. We expect the µ-RIA platform can successfully replace conventional tube-based radioimmunoassay in the future.

Detection of Sequence-Specific Gene by Multi-Channel Electrochemical DNA Chips

  • Zhang, Xuzhi;Ji, Xinming;Cui, Zhengguo;Yang, Bing;Huang, Jie
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권1호
    • /
    • pp.69-75
    • /
    • 2012
  • Five-channel electrochemical chips were fabricated based on the Micro-electromechanical System (MEMS) technology and were used as platforms to develop DNA arrays. Different kinds of thiolated DNA strands, whose sequences were related to white spot syndrome virus (WSSV) gene, were separately immobilized onto different working electrodes to fabricate a combinatorial biosensor system. As a result, different kinds of target DNA could be analyzed on one chip via a simultaneous recognition process using potassium ferricyanide as an indicator. To perform quantitative target DNA detection, a limit of 70 nM (S/N=3) was found in the presence of 600 nM coexisting noncomplementary ssDNA. The real samples of loop-mediated isothermal amplification (LAMP) products were detected by the proposed method with satisfactory result, suggesting that the multichannel chips had the potential for a high effective microdevice to recognize specific gene sequence for pointof-care applications.