• Title/Summary/Keyword: Micro-Step

Search Result 481, Processing Time 0.04 seconds

Plating Process of Micro-needle for MEMS Probe Card (MEMS Probe Card용 Micro Needle 공정 연구)

  • Han, Myung-Soo;Ahn, Su-Chang;Nam, An-Sik;Kim, Jang-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.152-152
    • /
    • 2008
  • Micro probe with Ni-Co tip was designed. Unit processes for fabricating the micro probe were developed. We are investigated the micro probe tip using by Ni-Co alloy. One-step and three-step needle was fabricated by plating process, CMP, and photolithography process. The plating thickness was varied by current density and time. Futher data will be extract by different process conditions.

  • PDF

Minimization of Initial Deflection of Multi-Layered Micro-Actuator with Step-Up Structure (Step-Up 구조를 갖는 다층박막 초소형 구동소자의 초기변형 최소화에 관한 연구)

  • Lee, Hee-Joong;Kang, Shin-Ill
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.11
    • /
    • pp.2415-2420
    • /
    • 2002
  • In the present study, a new anchor design was proposed to minimize the initial deflection of micro multi-layer cantilever beam with step-up structure, which is a key component of thin film micro-mirror array. It is important to minimize the initial deflection, caused by residual stress, because it reduces the performance of the actuation. Theoretical and experimental studies were conducted to examine the cause of the initial bending deflection. It was found that the bending deflection at the anchor of the cantilever beam was the primary source of initial deflection. Various anchor designs were proposed and the initial deflections for each design were calculated by finite element analysis. The analysis results were compared with experiments. To reduce the initial deflection a secondary support was added to the conventional structure. The optimal shapes were obtained by simulation and experiment. It was found from the analysis that the ratio or horizontal and vertical dimensions of secondary support was the governing factor, which affected the initial deflection.

CHARATERISTIC IMPROVEMENT OF 5 PHASE STEP MOTOR BY USING MICRO-STEP DRIVER IN X-Y AXIS SOLDERING MACHINE

  • Park, Chul-Soon;Kim, Sung-Hoon;Ahn, Ho-Kyun;Park, Seung-Kyu
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.97-100
    • /
    • 1998
  • In this paper, micro step driving method is used for the high performance motion control and low vibration and low noise in an X-Y axis soldering machine for factory automation. The improvement of the electrical and mechanical driving characteristic of a stepping motor is achieved by applying microstep driver.

  • PDF

Comparative evaluation of micro-shear bond strength between two different luting methods of resin cement to dentin (합착 술식에 따른 레진 합착제의 상아질에 대한 미세전단결합강도의 비교 연구)

  • Lee, Yoon-Jeong;Park, Sang-Jin;Choi, Kyoung-Kyu
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.4
    • /
    • pp.283-293
    • /
    • 2005
  • The purpose of this study was to evaluate the effect of dual bonding technique by comparing microshear bond strength between two different luting methods of resin cement to tooth dentin. Three dentin bonding systems(All-Bond 2, One-Step, Clearfil SE Bond), two temporary cements (Propac, Freegenol) were used in this study. In groups used conventional luting procedure, dentin surfaces were left untreated. In groups used dual bonding technique, three dentin bonding systems were applied to each dentin surface. All specimens were covered with each temporary cement. The temporary cements were removed and each group was treated using one of three different dentin bonding system. A resin cement was applied to the glass cylinder surface and the cylinder was bonded to the dentin surface. Then, micro-shear bond strength test was performed. For the evaluation of the morphology at the resin/dentin interface, SEM examination was also performed. 1. Conventional luting procedure showed higher micro-shear bond strengths than dual boning technique. However, there were no significant differences. 2. Freegenol showed higher micro-shear bond strengths than Propac, but there were no significant differences. 3. In groups used dual bonding technique, SE Bond showed significantly higher micro-shear bond strengths in One-Step and All-Bond 2 (p<0.05), but there was no significant difference between One-Step and All-Bond 2. 4. In SEM observation, with the use of All-Bond 2 and One-Step, very long and numerous resin tags were observed. This study suggests that there were no findings that the dual bonding technique would be better than the conventional luting procedure.

Design of High Performance 5 Phase Step Motor Drive System with Current Control Loop (전류 제어기를 가지는 고성능 5상 스텝 모터 구동 드라이버 설계)

  • Chun, Kwang-Su;Kim, Hak-Jin;Kwon, Yong-Kwan;Kang, Suk-Hee
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.5
    • /
    • pp.447-453
    • /
    • 2006
  • This paper proposes that 5 phase step motor drive system has high performance utilizing a micro step control with a current controller. Also this paper proposes an analog current controller to minimize size of the 5 phase step motor drive system. It has better advantages of cost and noise and heating than commercial products. As a result, Applying this system to position control robot the validity of suggested analog current controller and driver system is verified.

Characteristic analysis of low frequency vibration forming (저주파 가진 성형의 특성 분석)

  • Park, C.J.;Choi, J.P.;Park, D.Y.;Hong, N.P.;Lee, H.J.;Lee, N.K.;Kim, S.O.;Chu, Andy;Kim, B.H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2009.10a
    • /
    • pp.254-258
    • /
    • 2009
  • In this paper, the low frequency vibration forming system is developed for micro-patterns formation on the metal substrate. many researchers have studied about micro-forming technologies such as micro deep drawing, press forming, forging, extrusion etc. for the formation of precise micro-patterns on the surface of metal substrates, multi-step forming process must be used to improve qualifies of the deformed patterns. Since the low frequency vibration forming system could easily deform the surface of metal substrates, several steps of multi-step forming process should be removed by using the low frequency vibration forming system. In order to find optimal process conditions, we have carried out low frequency vibration forming process with varying the vibration frequency from 110Hz to 500Hz.

  • PDF

A Study on the Micro Hole Drilling of Stainless Steel (스테인레스 강의 미세구멍 드릴링 기술 연구)

  • Kim, Hyung-Kook;Yon, Kyu-Hyun;Song, Seung-Jong
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1517-1521
    • /
    • 2007
  • On this study, technical aspects were reviewed to drill a series of micro holes (${\phi}$0.10) over 200 within a few micron tolerance in diameter and position on the stainless steel material. Dedicated tools & jigs were designed and manufactured and optimum cutting conditions were found. On this micro hole drilling process, guide drill and step feeding were applied to help chip discharge, prevent drill breakage and finally improve the accuracy of positioning and roundness. The processing results indicated that most holes are distributed within a few micron tolerance in diameter and position intervals.

  • PDF

The analysis of electrical characteristics with Micro-crack in PV module (Micro-cracks에 의한 PV 모듈의 전기적 특성 분석)

  • Song, Young-Hun;Ji, Yand-Geun;Kim, Kyung-Soo;Kang, Gi-Hwan;Yu, Gwon-Jong;Ahn, Hyung-Gun;Han, Deuk-Young
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.25-30
    • /
    • 2011
  • In this paper, we analyzed the electrical characteristics with Micro-cracks in Photovoltaic module. Micro cracks are increasing the breakage risk over the whole value chine from the wafer to the finished module, because the wafer or cell is exposed to mechanical stress. And The solar cells have to with stand the stress under out door operation in the finished module. Here the mechanical stress is induced by temperature changes and mechanical loads from wind and snow. So, we experimentally analyze the direct impact of micro-cracks on the module power and the consequences after artificial aging. The first step, we made micro-cracks in PV module by mechanical load test according to IEC 61215. Next, PV modules applied the thermal cycling test, because micro-cracks accelerated aging by thermal cycling test, according to IEC61215. Before every test, we checked output and EL image of PV module. As the result of first step, we detected little power loss(0.9%). But after thermal cycling test increased power loss about 3.2%.

  • PDF

Static Characteristics Investigation of LPM According to Input Current Waveforms (입력 전류 파형에 따른 LPM의 정특성 고찰)

  • 허두석;조윤현
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.7
    • /
    • pp.409-416
    • /
    • 2004
  • This paper presents the selection method o( the input current wave forms for the thrust force ripple of linear pulse motor (LPM). We have developed and tested a prototype 2-phase 4-poles LPM with the permanent magnet and its control driver. To obtain the thrust performance curve of LPM, the performance curve at the air gap and the thrust are calculated and estimated by the analytical method on the base of the magnetic equivalent circuit and the finite element method. And, the thrust characteristics at the static operation state are analyzed and experimented with the respect to the input wave forms such as the rectangular, the triangular micro-step and the sine micro-step wave forms to investigate the thrust ripple and the vibration effects of LPM.

Estimation of Dinucleotide Step Parameters of Double Helix Structure on MicroRNA Using Genetic Algorithms (유전알고리즘을 이용한 MicroRNA 이중나선 구조의 Dinucleotide Step 파라미터 추정)

  • Nam Jin-Wu;Zhang Byoung-Tak
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2005.07b
    • /
    • pp.262-264
    • /
    • 2005
  • MicroRNA는 약 22 nucleotide 길이로, 세포질에서 유전자의 전사 후 조절 기능을 맡는 small RNA의 한 종류이다. MiRNA는 긴 전사체인 pri-miRNA에서 Drosha에 의해 절단 되어 핵 밖으로 나가 최종 Dicer에 의해 성숙된다. 하지만, 아직까지 이 효소들이 pri-miRNA를 잘라내는 3차 구조상의 메커니즘을 이해하지 못하고 있다. 본 연구에서는 완숙한 miRNA 이중나선이 약 2 회전을 이루게 된다는 정보를 바탕으로, Drosha가 붙는 miRNA stem구조의 dinucleotide step 파라미터를 유전 알고리즘을 이용하여 추정한다. 추정된 파라미터로부터 실제 miRNA들의 3차구조를 예측할 수 있으며, 3차 구조상의 Drosha의 절단 메커니즘을 이해하는데 도움을 줄 것이다.

  • PDF