• 제목/요약/키워드: Method overloading

검색결과 60건 처리시간 0.027초

Numerical investigations on stability evaluation of a jointed rock slope during excavation using an optimized DDARF method

  • Li, Yong;Zhou, Hao;Dong, Zhenxing;Zhu, Weishen;Li, Shucai;Wang, Shugang
    • Geomechanics and Engineering
    • /
    • 제14권3호
    • /
    • pp.271-281
    • /
    • 2018
  • A jointed rock slope stability evaluation was simulated by a discontinuous deformation analysis numerical method to investigate the process and safety factors for different crack distributions and different overloading situations. An optimized method using Discontinuous Deformation Analysis for Rock Failure (DDARF) is presented to perform numerical investigations on the jointed rock slope stability evaluation of the Dagangshan hydropower station. During the pre-processing of establishing the numerical model, an integrated software system including AutoCAD, Screen Capture, and Excel is adopted to facilitate the implementation of the numerical model with random joint network. These optimizations during the pre-processing stage of DDARF can remarkably improve the simulation efficiency, making it possible for complex model calculation. In the numerical investigations on the jointed rock slope stability evaluations using the optimized DDARF, three calculation schemes have been taken into account in the numerical model: (I) no joint; (II) two sets of regular parallel joints; and (III) multiple sets of random joints. This model is capable of replicating the entire processes including crack initiation, propagation, formation of shear zones, and local failures, and thus is able to provide constructive suggestions to supporting schemes for the slope. Meanwhile, the overloading numerical simulations under the same three schemes have also been performed. Overloading safety factors of the three schemes are 5.68, 2.42 and 1.39, respectively, which are obtained by analyzing the displacement evolutions of key monitoring points during overloading.

Special Protection and Control Scheme for Transmission Line Overloading Elimination Based on Hybrid Differential Evolution/Electromagnetism-Like Algorithm

  • Hadi, Mahmood Khalid;Othman, Mohammad Lutfi;Wahab, Noor Izzri Abd
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권5호
    • /
    • pp.1729-1742
    • /
    • 2017
  • In designing System Protection Schemes (SPSs) in power systems, protecting transmission network against extreme undesired conditions becomes a significant challenge in mitigating the transmission line overloading. This paper presents an intelligent Special Protection and Control Scheme (SPCS) using of Differential Evolution with Adaptive Mutation (DEAM) approach to obtain the optimum generation rescheduling to solve the transmission line overloading problem in system contingency conditions. DEAM algorithm employs the attraction-repulsion idea that is applied in the electromagnetism-like algorithm to support the mutation process of the conventional Differential Evolution (DE) algorithm. Different N-1 contingency conditions under base and increase load demand are considered in this paper. Simulation results have been compared with those acquired from Genetic Algorithm (GA) application. Minimum severity index has been considered as the objective function. The final results show that the presented DEAM method offers better performance than GA in terms of faster convergence and less generation fuel cost. IEEE 30-bus test system has been used to prove the effectiveness and robustness of the proposed algorithm.

Performance Improvement of an Active Neutral Harmonic Suppressor System Under Unbalanced Load Conditions

  • Choi, Se-Wan;Jang, Min-Soo
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.822-828
    • /
    • 2001
  • Three-phase four-wire electrical distribution systems are widely employed in manufacturing plants, commercial and residential buildings. Due to the nonlinear loads connected to the distribution system, the neutral conductor carries excessive harmonic currents even under balanced loading since the triplen harmonics in phase currents do not cancel each other. This may result in wiring failure of the neutral conductor and overloading of the distribution transformer. In response to these concerns, a cost-effective neutral current harmonic suppressor system has been proposed [6]. This paper proposes an improved control method for the harmonic suppressor system under unbalanced load conditions. The proposed control method compensates for only the harmonic components in the neutral conductor, and the zero-sequence fundamental component due to unbalanced loading is prevented from flowing through the harmonic suppressor system. This remedies overloading and power loss of the system. The experimental results on a prototype validate the proposed control approach.

  • PDF

Performance Improvement of an Active Neutral Harmonic Suppressor System Under Unbalanced Load Conditions

  • Choi, Se-Wan;Jang, Min-Soo
    • Journal of Power Electronics
    • /
    • 제3권3호
    • /
    • pp.151-158
    • /
    • 2003
  • Three-phase four-wire electrical distribution systems are widely employed in manufacturing plants, commercial and residential buildings Due to the nonlinear loads connected to the distribution system, the neutral conductor carries excessive harmonic currents even under balanced loading since the triplen harmonics in phase currents do not cancel each other This may result in wiring failure of the neutral conductor and overloading of the distribution transformer In response to these concerns, a cost-effective neutral current harmonic suppressor system has been proposed. This paper proposes an improved control method for the harmonic suppressor system under unbalanced load conditions The proposed control method compensates for only the harmonic components in the neutral conductor, and the zero-sequence fundamental component due to unbalanced loading is prevented from flowing through the harmonic suppressor system This remedies overloading and power loss of the system The experimental results on a prototype validate the proposed control approach.

Piezoelectric skin sensor for electromechanical impedance responses sensitive to concrete damage in prestressed anchorage zone

  • Dang, Ngoc-Loi;Pham, Quang-Quang;Kim, Jeong-Tae
    • Smart Structures and Systems
    • /
    • 제28권6호
    • /
    • pp.761-777
    • /
    • 2021
  • This study presents a numerical investigation on the sensitivity of electromechanical (EM) impedance responses to inner damaged concrete of a prestressed anchorage zone. Firstly, the Ottosen yield criterion is selected to simulate the plasticity behavior of the concrete anchorage zone under the compressive loading. Secondly, several overloading cases are selected to analyze inner damage formations in the concrete of the anchorage zone. Using a finite element (FE) model of the anchorage zone, the relationship between applied forces and stresses is analyzed to illustrate inner plasticity regions in concrete induced by the overloading. Thirdly, EM impedance responses of surface-mounted PZT (lead-zirconate-titanate) sensors are numerically acquired before and after concrete damage occurrence in the anchorage zone. The variation of impedance responses is estimated using the RMSD (root-mean-square-deviation) damage metric to quantify the sensitivity of the signals to inner damaged concrete. Lastly, a novel PZT skin, which can measure impedance signatures in predetermined frequency ranges, is designed for the anchorage zone to sensitively monitor the EM impedance signals of the inner damaged concrete. The feasibility of the proposed method is numerically evaluated for a series of damage cases of the anchorage zone. The results reveal that the proposed impedance-based method is promising for monitoring inner damaged concrete in anchorage zones.

상정사고를 고려한 ATC 계산에 관한 연구 (A Study on the Available Transfer Capability(ATC) calculation with Contingency)

  • 정성원;황건호;김양일;김재현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.296-297
    • /
    • 2008
  • This paper proposed a methods to ATC calculation using energy function. In this paper, ATC was calculated as PTDF, LODF, RPF and Energy Function method and calculation results of each methods was compared. Contingency ranking method decided the overloading branches by PI-index. As a result, a study proved the fast and accurate ATC calculation method considering contingency suggested in this paper.

  • PDF

안드로이드 저작권 보호를 위한 메소드 생성 기반 워터마킹 기법의 설계 및 구현 (Design and Implementation of Method Generation based Watermarking Technique for Android Copyright Protection)

  • 박희완
    • 한국융합학회논문지
    • /
    • 제10권1호
    • /
    • pp.61-69
    • /
    • 2019
  • 스마트폰이 널리 보급되고 수많은 애플리케이션들이 개발됨에 따라서 소프트웨어 저작권 관련하여 사회적인 이슈가 발생하고 있다. 소프트웨어 워터마킹은 디지털 워터마킹 기술을 소프트웨어에 적용한 것으로서 소프트웨어 원저작권자를 판별하는데 사용될 수 있는 기술이다. 안드로이드 환경에서 앱을 개발하기 위해서 일반적으로 자바 언어를 사용한다. 자바는 객체지향 언어로서 메소드 오버로딩과 오버라이딩을 지원한다. 본 논문에서는 메소드 생성 기반 워터마킹 기법을 제안하고 구현하였다. 워터마크로 인한 오버헤드를 평가한 결과, 실행 파일 크기의 증가와 실행 속도의 저하가 크지 않다는 것을 확인하였다. 본 논문에서 제안하는 워터마킹 기법을 사용하면 불법 복제가 의심되거나 실제로 프로그램이 도용되었을 때 저작권 정보를 확인할 수 있으며 불법 복제 시도를 사전에 예방하는 효과도 있을 것으로 기대한다.

유비쿼터스 컴퓨팅을 위한 온톨로지 기반의 서비스 기술 및 오버로딩 기법 (Ontology-based Service Description and Overloading Method for Ubiquitous Computing)

  • 이미연;이정원;박승수;조위덕
    • 정보처리학회논문지B
    • /
    • 제15B권5호
    • /
    • pp.465-476
    • /
    • 2008
  • 이질성, 이동성, 가변성 등의 특징을 갖는 유비쿼터스 컴퓨팅 환경에서 사용자의 의도에 맞도록 자율적이고 동적인 서비스를 제공하기 위해서는, 실시간의 상황을 고려하여 목적 달성에 필요한 서비스들을 합성할 수 있는 기법과, 이를 가능케 하는 효과적인 서비스 기술 및 관리 방법이 전제되어야 한다. 본 연구에서는, 도메인 내의 서비스를 추출하여 서비스 온톨로지로 구조화하는 메커니즘을 제안한다. 추출된 서비스는 제안한 서비스 규격에 따라 기술되고 온톨로지 내에서 계층적인 구조를 이루게 된다. 이를 근간으로 사용자는 다양한 추상화 레벨의 서비스를 사용하여 목표를 기술할 수 있고, 서비스 오버로딩 기법을 통해 실행 시에 가장 적합한 서비스가 선택된다. 또한, 요청한 서비스가 유효하지 않은 경우에도 서비스 온톨로지를 참조하여 대체 서비스를 찾을 수 있는 합성 방법을 제안한다. 구축한 서비스 온톨로지에 대한 실험 결과, 비구 조화된 서비스 리스트를 사용하는 것보다, 서비스 온톨로지를 사용함으로써 사용자의 목적 달성 성공률을 높일 수 있을 뿐만 아니라 서비스의 바인딩 시간도 감소시킬 수 있음을 보였다.

제과공장의 폐수처리장에서 발생하는 악취 저감 (Reduction of the Offensive Odor from Confectionery Wastewater Plant)

  • 김영식;손병현;조상원;정종현
    • 한국환경보건학회지
    • /
    • 제24권1호
    • /
    • pp.62-69
    • /
    • 1998
  • It has been studied that the measurement of odor component emission at confectionery manufacture. The objects of this study were to investigate reduction of offensive odor. The survey effects of odorous materials are presented as follows. The countermeasure of operating process is to minimize sludge sediment in each unit facility. Especially, in summer, we have to clean the sludge frequently, because anaerobic decomposing is likely to occur easily. The sludge or scum from sedimentation tank pond, and floating tank should be treated quickly. We should avoid overloading operation. In the case of overloading, dissolved oxygen should be increased, the quality of wastewater input should be decreased. When dried cakes from condense tank or floating tank are left in treatment plant, we should cover, to prevent diffusion of smell with masking materials. The seasonal condition of operating should be fixed and the kind of coagulants should be changed because the wastewater in each season have different loading rates and organic materials. Odorous materials are very sensitive to the seasonal temperature variation. Especially, when the amount of rainfall is small and the high temperature of maintenance in long periods, air diffusion rate is large, so odorous materials can make great effect on surroundings comparision with other periods. To reduce odorous gas, as short term method, we had better take ceramic addition method. Especially, in summer we should take ceramic addition method. Also, as long term method, the size of wastewater treatment facility is the most important in the normal operating of wastewater treatment facility. But wastewater treatment facilities in this factory are too old, treatment process is old fashion, and the size is too small. So, large wastewater quantity to treat in summer. As results, the expansion of wastewater treatment facility and the process of improvement are required. Restriction level of odor was exceed. As it is overloaded in summer, the basis cause of odor is that the size of wastewater treatment facility is small. The prediction of air quality equilibrium density variation show that the odorous materials from working place are Amine materials whose smell strength is about 2.5(a little strong degree). We can suppose that in summer is sensitive to temperature variation, smell strength is larger as to reduce the origin of odor. We must expand wastewater treatment facility and improve the process A.S.A.P.

  • PDF

숏넥 플랜지의 공정설계에 관한 연구 (A Study on the Process Sequence Design of a Short-Neck Flange)

  • 장용석;최진화;고병두;이호용;황병복
    • 한국정밀공학회지
    • /
    • 제17권6호
    • /
    • pp.127-134
    • /
    • 2000
  • The current three-stage cold farming process to produce a flange is investigated for the purpose of improvement of manufacturing process. The main goal of this study is to obtain an appropriate process sequence, which can produce the required part with less manufacturing cost. The current process sequence is simulated using finite element method and design criteria are examined. Based on the results of simulation of the current three-stage process. a design strategy for improving the process sequence is analyzed using the thick-walled pipes. Because it has a reduced process-sequence without buckling of the workpiece or overloading of tools, the new process has distinct advantages over the conventional process. Numerical results show that the newly proposed process with selected presses is the most economical way to produce the required part.

  • PDF