Performance Improvement of an Active Neutral Harmonic Suppressor System Under Unbalanced Load Conditions

  • Choi, Se-Wan (Dept. of Control and Instrumentation Eng., Seoul National University of Tech.) ;
  • Jang, Min-Soo (Dept. of Control and Instrumentation Eng., Seoul National University of Tech.)
  • Published : 2003.07.01

Abstract

Three-phase four-wire electrical distribution systems are widely employed in manufacturing plants, commercial and residential buildings Due to the nonlinear loads connected to the distribution system, the neutral conductor carries excessive harmonic currents even under balanced loading since the triplen harmonics in phase currents do not cancel each other This may result in wiring failure of the neutral conductor and overloading of the distribution transformer In response to these concerns, a cost-effective neutral current harmonic suppressor system has been proposed. This paper proposes an improved control method for the harmonic suppressor system under unbalanced load conditions The proposed control method compensates for only the harmonic components in the neutral conductor, and the zero-sequence fundamental component due to unbalanced loading is prevented from flowing through the harmonic suppressor system This remedies overloading and power loss of the system The experimental results on a prototype validate the proposed control approach.

Keywords

References

  1. T.M. Gruzs, 'Power System Problems from High Harmonic Neutral Current', Computer Tech. Rev., winter 1988
  2. T.M. Gruzs, 'A Survey of Neutral Current in Three-Phase Computer Power System', IEEE Trans. on Ind. Appl. Vol. 26, No. 4, pp. 719-725, Jul/Aug. 1990 https://doi.org/10.1109/28.55999
  3. Prem P. Khera, 'Application of Zigzag Transformers for Reducing Harmonics in the Neutral Conductor of Low Voltage Distribution System', IEEE IAS Conf. Rec., 1990
  4. C.A. Quinn and N. Mohan, 'Active Filtering of Harmonic Currents in Three-Phase, Four-Wire Systems with Three-Phase and Single-Phase Non-Linear Loads', APEC 1992, pp. 829-835
  5. B. Singh, K. AI-Haddad, and A. Chandra, 'Active Power Filter for Harmonic and Reactive Power Compensation in Three-Phase, Four-Wire Systems Supplying Non-Linear Loads', ETEP, Vol. 8, Vo. 2, pp.139-145, March/April
  6. P.N. Enjeti and W. Shiren, 'Analysis and Design of a New Active Power Filter to Cancel Neutral Current Harmonics in Three-Phase Four-Wire Electric Distribution Systems', IEEE Trans. Ind. Appl., Vol. 30, No. 6, pp. 1565-1572, Nov./Dec. 1994 https://doi.org/10.1109/TIA.1994.350311
  7. J. Reeve and P.C. S. Krishnayya, 'Unusual current harmonics arising from high voltage DC transmission', IEEE Trans. Power App. System, Vol. PAS-87, No.3, pp. 883-893, Mar. 1968