• Title/Summary/Keyword: Membrane Flux

Search Result 1,023, Processing Time 0.024 seconds

Surface reactive micro/nano particles on inorganic oxygen separation membrane

  • Lee, Kee-Sung;Shin, Tae-Ho;Lee, Shiwoo;Woo, Sang-Kuk;Yang, Jae-Kyo;Choa, Yong-Ho
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2004.05a
    • /
    • pp.94-97
    • /
    • 2004
  • Micro/nano-sized L $a_{0.6}$S $r_{0.4}$Co $O_{3-}$$\delta$/ particles are considered to improve oxygen permeability in highly selective inorganic oxygen separation membrane. A L $a_{0.7}$S $r_{0.3}$G $a_{0.6}$F $e_{0.4}$ $O_{3-}$$\delta$/ membrane with perovskite structure is fabricated by a conventional solid-state reaction. As the oxygen permeation flux of the L $a_{0.7}$S $r_{0.3}$G $a_{0.6}$F $e_{0.4}$ $O_{3-}$$\delta$/ membrane was lower than commercial gas separation membranes, we coated the L $a_{0.6}$S $r_{0.4}$Co $O_{3-}$$\delta$/ particles to enhance the oxygen permeation flux. It has been demonstrated that the effective area of reactive free surface is an important factor in determining the effectiveness of the introduction of coating layer for oxygen permeation. The introduction of micro/nano L $a_{0.6}$S $r_{0.4}$Co $O_{3-}$$\delta$/ particles was very effective for increasing oxygen flux, as the flux was as much as 2 to 6 times higher than that of an uncoated L $a_{0.7}$S $r_{0.3}$G $a_{0.6}$F $e_{0.4}$ $O_{3-}$$\delta$/ membrane.\delta$/ membrane.>/ membrane.brane.

  • PDF

Characteristics of the Sinusoidal Flux Continuous Operation Mode for the Submerged Flat-sheet Membrane Module in Cutting Oil Solution (절삭유 수용액내 침지식 평막 모듈에 대한 사인파형 투과유속 연속운전 방식의 특성)

  • Won, In Hye;Chung, Kun Yong
    • Korean Chemical Engineering Research
    • /
    • v.53 no.5
    • /
    • pp.646-652
    • /
    • 2015
  • In this study transmembrane pressure (TMP) was measured with respect to permeate flux through the submerged flat sheet membrane for the emulsion and semi-synthetic cutting oil solutions. The effective area and nominal pore size of the used microfiltration membrane were $0.02m^2$ and $0.15{\mu}m$, respectively. The experiments were carried out simultaneously for run/stop (R/S) and sinusoidal flux continuous operation (SFCO) modes using two submerged membrane module in the reservoir. TMP for the case of SFCO was maintained under 60% of R/S, and the effect on TMP drop decreased as the permeate flux increased for emulsion cutting oil solution. Membrane fouling for the semisynthetic solution showing low turbidity was induced lower comparing to the emulsion solution. Also, the effect on TMP drop for SFCO decreased during long-term operation.

Effects of Surface Water Chemistry and Physicochemical Characteristics of Humic Acid on Fouling of Membrane (원수의 수질화학과 HA의 물리화학적 특성이 막 오염에 미치는 영향)

  • Bae, Jin-Youl;Han, Ihnsup;Park, Sung-Ho;Shin, Jee-Won
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.3
    • /
    • pp.242-247
    • /
    • 2005
  • In this study, we investigated the removal efficiencies of pollutants and permeate fluxes depending on chemistry of feed water, various molecular weight cut-offs (MWCOs) and materials of membrane, operating pressure. We used seven MWCO membranes of YC0.5, YM1, YM3, YM10, YM30, YM100 and PM30, humic acid solution and surface water as feed water, and examined variation in permeate flux. Results of TOC removal experiment demonstrate that MWCO lower 1,000daltons could remove humic acid effectively. As increasing solution pH and decreasing divalent cations ($Ca^{2+}$) concentration, TOC removal increased. But $UV_{254}$ removal efficiency increased with higher divalent cation concentration and solution pH. Membrane fouling increased with increasing electrolyte (NaCl), divalent cation concentration and decreasing solution pH. In spite of initial permeate flux of the hydrophobic membrane (PM30) was higher than that of the hydrophilic membrane (YM30), flux decline of PM30 was significant during operation. At higher operating pressure, compactness of the cake layer on the membrane surface increased, resulting in gradual increase in hydraulic resistance.

Optimization of Ultrafiltration Process using $MIEX^{(R)}$+Coagulation Process ($MIEX^{(R)}$+응집공정을 이용한 한외여과 공정의 최적화 : 다양한 전처리 공정의 적용에 따른 막 오염 현상 규명)

  • Son, Hee-Jong;Hwang, Young-Do;Roh, Jae-Soon;Jung, Chul-Woo;Kang, Lim-Seok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.7
    • /
    • pp.753-761
    • /
    • 2005
  • In this study, pretreatment of organic matters with $MIEX^{(R)}$ was evaluated using bench-scale experimental procedures on four organic matters to determine its effect on subsequent UF membrane filtration. For comparison, coagulation process was also used as a pretreatment of UF membrane filtration. Moreover, the membrane fouling potential was identified using different fractions and molecular weights of organic matters. From the removal property of MW organic matters by coagulation process for the sample water NOM and AOM, the removal efficiency of high MW organic matters were much higher than those of low MW organic matters. It was shown that the removal efficiency of high MW organic matter more than 10 kDa was lower than that of low MW organic matter for $MIEX^{(R)}$ process. For the change of permeate flux by the pretreatment process, $MIEX^{(R)}$+UF process showed high removal efficiency of organic matter as compared with coagulation-UF processes, but high reduction rate of permeate flux was presented through the reduction of removal efficiency of high MW organic matter. From sequential filtration test results in order to examine the effect of MW of organic matter on membrane fouling, it was found that the membrane foulant was occurred by high MW organic matter, and the DOC of organic matter less than 0.5 mg/L was working as the membrane foulant. In the case of sample water composed of low MW organic matter less than 10 kDa, since the low MW organic matter less than 10 kDa has high removal efficiency by $MIEX^{(R)}$, low reduction rate of permeate flux is obtained as compared with coagulation-UF processes. In summary, it is required to conduct the research on physical/chemical characteristic of original water before pretreatment process of membrane process is selected, and a pertinent pre-treatment process should be employed based on the physical/chemical characteristic of original water.

Effects of various foulants on flux changes in membrane distillation process (막증류 공정에서 오염 인자가 플럭스 변화에 미치는 영향)

  • Park, Chansoo;Lee, Chang-Kyu;Kim, Jong-oh;Choi, June-Seok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.3
    • /
    • pp.327-334
    • /
    • 2016
  • The effects of dissolved inorganic and organic matter in seawater and the characteristics of fouling on the membrane surface were investigated within membrane distillation (MD) process. The changes of the membrane flux of PE and PVDF hollow fiber membranes under natural and synthetic seawater were compared with given variances of temperature. The flux of both membranes under the synthetic seawater, without any organic matter, were higher than that of the natural seawater, indicating the organic fouling on the membrane surface. The surface of the membrane was analyzed using scanning electron microscope (SEM) to examine the fouling. The experiment with organics has shown the formation of thin film over the membrane surface, while the experiment with inorganics has shown only the formation of inorganic crystals. The results indicated the organic matter as the major foulants and that the organics affected the formation of the crystals. Permeate water conductivity of all conditions verified the quality of the water to be better if not similar to that of RO.

Permeation Characteristics of the Tubular Membrane with Continuous Air Cleaning System (연속식 공기세정 관형막 투과특성)

  • Park, Mi Ja;Chung, Kun Yong
    • Membrane Journal
    • /
    • v.23 no.2
    • /
    • pp.185-188
    • /
    • 2013
  • This study was carried out for microfiltration tubular membrane module equipped with self-designed air injection nozzle in order to determine the permeate flux due to the effect of membrane fouling reduction. The 0.1 wt% yeast particle solution was used as a feed solution and permeation tests were performed for the cases with and without air injection. Permeation fluxes were measured and analyzed to examine the effect of membrane fouling reduction. While the permeation flux without air injection decreased continuously, that with air injection was improved more than 30 percent than that of no air injection case.

Reuse of Weaving Wastewater by Membrane Bioreactor Equipped with a Hollow-fiber MF Membrane (중공사 정밀여과 MBR공정을 이용한 제직폐수의 재이용)

  • Jung, Yong-Jun;Bae, Jong-Hong;Min, Kyung-Sok
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.4
    • /
    • pp.365-369
    • /
    • 2004
  • Submerged membrane bio-reactor equipped with a hollow fiber microfiltration was applied to reuse weaving wastewater of water jet loom, where two parameters such as the concentration of MLSS and the flux were controlled. While the flux at the concentration of MLSS around 900mg/L was constantly kept over 0.4m/d and 0.8m/d in a short time, the stable flux at around 300mg/L of MLSS was shown at the 8 days later. Regardless of MLSS and flux, BOD, CODcr and Turbidity of the permeate were 1~2mg/L, 7~10mg/L and below 1 NTU, which were 85~90%, 87~90% and 98% of removal efficiency, respectively. The stable operation without fouling was achieved because the contents of ECP were smaller than those of common MBR processes and the composition(saccharide/protein) was kept constantly. In this study, 0.5~1.0m/d of flux and 400~900mg/L of MLSS were considered as the most recommendable operating condition for the reuse of weaving wastewater.

Performance and characterization of PEG400 modified PVC ultrafiltration membrane

  • Aryanti, P.T.P.;Yustiana, R.;Purnama, R.E.D.;Wenten, I.G.
    • Membrane and Water Treatment
    • /
    • v.6 no.5
    • /
    • pp.379-392
    • /
    • 2015
  • Polyvinyl chloride (PVC) ultrafiltration membrane was prepared by blending 12 wt.% of PVC in N, N-dimethylacetimide (DMAc) with polyethylene glycol 400 (PEG400) as an additive. The influence of PEG400 concentration on the PVC membrane morphology, permeability, fouling and rejection were investigated. Fouling and rejection of the PVC membrane were characterized by dextran T-100 filtration. The results showed that membrane water flux was increased up to $682Lm^{-2}h^{-1}$ when 28 wt.% of PEG400 was added into the PVC membrane solution. The best membrane performance with a low fouling and a high selectivity was achieved by adding 12 wt.% concentration of PEG400, which resulted in 90% rejection of dextran and 90% of flux recovery ratio. At further addition of PEG400 concentration, irreversible fouling was starting to increase. A 90% of irreversible fouling was formed in the PVC membrane when more than 22 wt.% of PEG400 is added.

The Degumming and Sericin Recovery of the Silk fabric Using the Electrolytic Water(II) (전해수를 이용한 견섬유 정련 및 세리신 회수(II)-분리막에 의한 세리신 농축을 중심으로-)

  • 배기서;이태상;노덕길;홍영기
    • Textile Coloration and Finishing
    • /
    • v.16 no.4
    • /
    • pp.10-18
    • /
    • 2004
  • In this work, Aqueous sericin solution was prepared by degumming process with electrolytic reduction water. Then, the microfiltration and ultrafiltration systems were applied to the concentration of aqueous sericin solution. The objective of this study was to select the optimum operating condition among the different pressure. The permeate flux and rejection ratio were observed with time, pressure, flow rate and concentration. and, the wastewater and permeated water quality values such as pH, BOD, COD, and NH levels were measured. In order to see the influence of electrolytic reduction water, the flux of pure water and electrolytic reduction water by PVDF22(MF) and PS100(UF) membrane was measured. In microfiltration system, the relative flux reduction decreased rapidly to 0.02 in the 30min, as the concentration polarization and gel layer formation were increased. and then the sericin concentration rejection ratio was 40%. In ultrafiltration system, the permeate flux decreased with time and concentration, and increased with the operating pressure and flow rate. Optimal condition in PS100 membrane system for sericin concentration was operating pressure 1.464kgf/$cm^24, operating flow rate $7\ell/min at\; 40^{\circ}C$. At that time, sericin concentration rejection ratio was 83% respectably. The sericin solution was concentrated from 0.1wt% solution to 0.2 wt % solution during about 2 hrs by the UF filteration membrane system.

Choline chloride-Glycerol (1:2 mol) as draw solution in forward osmosis for dewatering purpose

  • Dutta, Supritam;Dave, Pragnesh;Nath, Kaushik
    • Membrane and Water Treatment
    • /
    • v.13 no.2
    • /
    • pp.63-72
    • /
    • 2022
  • Choline chloride-glycerol (1:2 mol), a natural deep eutectic solvent (NADES) is examined as a draw solution in forward osmosis (FO) for dewatering application. The NADES is easy to prepare, low in toxicity and environmentally benign. A polyamide thin film composite membrane was used. Characterization of the membrane confirmed porous membrane structure with good hydrophilicity and a low structural parameter (722 ㎛) suitable for FO application. A dilute solution of 20% (v/v) NADES was enough to generate moderate water flux (14.98 L m-2h-1) with relatively low reverse solute flux (0.125 g m-2h-1) with deionized water feed. Application in dewatering industrial wastewater feed showed reasonably good water flux (11.9 L m-2h-1) which could be maintained by controlling the external concentration polarization and fouling/scaling mitigation via simple periodic deionized water wash. In another application, clarified sugarcane juice could be successfully concentrated. Recovery of the draw solute was accomplished easily by chilling utilizing thermo responsive phase transition property of NADES. This study established that low concentration NADES can be a viable alternative as a draw solute for dewatering of wastewater and other heat sensitive applications along with a simple recovery process.