제너 다이오드를 이용한 공기 유속계측 장치개발

  • 김영재;김희식;조흥근
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 추계학술대회 논문집
    • /
    • pp.496-500
    • /
    • 1996
  • An air flow measurement device is proposed. The thermal characteristic of a semiconductor element is adopted as a cooling parameter of thermal convection rate. The difference between forced convection and natural convection of two Zener diodes results enough difference in temperature. Experiment at various air flow conditions shows the measuring capability of the air flow in a duct. This measuring device has some merits, such as a reliability n hard field condition, simple circuit for signal processing, small volume of the element, less air flow resistance, independance of various ai temperature. The experimental result shows that it is an exact and usefull air flow measurement device.

  • PDF

로드셀과 토크암을 이용한 대용량 토크 측정장치 개발에 관한 연구 (Development of device measuring very high torque via torque arm with attached load cells)

  • 이용범;한승호
    • 유공압시스템학회논문집
    • /
    • 제7권1호
    • /
    • pp.6-10
    • /
    • 2010
  • A measurement of very high torque for track drive unit in construction equipment is usually in difficulties due to the requirement of a torque meter with high capacity, and the limitation of geometry for an experimental set-up. To improve the troublesome problem, a new device was proposed, where a torque transmitted through the torque arm can be measured by load cells attached at each torque arm. The experimental set-up of the new device was carried out in order to measure the torque values for a mechanical feedback type planetary gear box, in which the power flow circulates itself in a closed-loop. The new device enables to measure torque values of 60,000Nm. Additionally, the measured values were estimated statistically in the aspect of their repeatability and reproducibility, so that an acceptable behaviour as a measuring device can be confirmed.

  • PDF

스마트 3축 힘센서 설계 (Design of Smart Three-Axis Force Sensor)

  • 이경준;김현민;김갑순
    • 제어로봇시스템학회논문지
    • /
    • 제22권3호
    • /
    • pp.226-232
    • /
    • 2016
  • This paper describes the design of a smart three-axis force sensor for measuring forces Fx, Fy and Fz. The smart three-axis force sensor is composed of a three-axis force sensor, a force-measuring device, housing and a cover, where the three-axis force sensor and the force-measuring device are inside the housing and the cover. The measuring device measures forces Fx, Fy and Fz from the three-axis force sensor, and calculates the resultant force using the measured forces, and then sends the resultant force and forces to a PC or other controller using RS-485 communication. The repeatability error and the non-linearity error of the smart three-axis force sensor are less than 0.03%, and the interference error of the sensor is less than 0.87%. It is thought that the sensor can be used for measuring forces in a robot, automatic systems and so on.

GIS용 피뢰기 누설전류 측정장치 성능개선 (The Performance Improvement of Lightning Arrester Leakage Current Measuring Device for GIS)

  • 김원규;김민수;백영식
    • 전기학회논문지
    • /
    • 제63권12호
    • /
    • pp.1726-1731
    • /
    • 2014
  • This paper shows the developed new lightning arrester LCM (Leakage Current Measuring device) which is important element of GIS (Gas Insulated Switchgear) Preventive & Diagnostic system and verify its performance though strengthened test standards. The existing lightning arrester LCM was modified to solve measuring errors which happened frequently. At first, we explained the principle of measuring leakage current. Through analyzing some problems which the existing LCM have. we got some improvable items. For the performance verification of the improved LCM, we manufactured prototype LCM which is applied some improvable items such as improving LCM circuit, adding protection circuit, optimizing inner structure of LCM and changing ground design. After then we carried out the performance test. Accredited testing laboratory carried out the performance verification test according to performance test criteria and procedure of reliability test standards, IEC-60225, 61000 and 60068 etc. We confirmed the test results which correspond with the performance test criteria. Also, we confirmed the performance of the improved LCM installed & being operated at G Substation through the immunity test against the normal noise and open/close surge etc.

가변 사판식 압축기의 탑 클리어런스 측정 방법 및 신뢰성 확보에 관한 연구 (Study on the Measuring Method and Reliability of Top Clearance of Variable Swashplate Type Compressor)

  • 김영신;나승규
    • 설비공학논문집
    • /
    • 제28권3호
    • /
    • pp.89-94
    • /
    • 2016
  • In this experimental study, the effects of top clearance on the performance of automotive a/c compressor were studied. Top clearance measuring device was also developed to ensure the reliability using vacuum conditions to secure constant control of top clearance without external environmental influence. Our results revealed that the improvements in compressor performance according to different top clearance values using the same compressor and same operator were about 4.12% at 800 rpm and about 7.8% at 2,000 rpm in 0.243~0.252 mm of top clearance compared to 0.431~0.456 mm of top clearance. To confirm the consistency in measuring top clearance affecting compressor performance, the top clearance measuring device was developed in this study using a vacuum pump. After performing reliable tests repeatedly, the distribution of measuring values under this device was within 0.99~1.83%, indicating that the constant test data in compressor performance was not affected by any other external environment.

Development of a Femur Neck Bone Mineral Density Measuring Device for Accurate Examination

  • Han, Man-Seok;Seo, Sun-youl;Kim, Yong-Kyun;Jeon, Min-Cheol;Lee, Hyun-kuk;Yoo, Se-Jong
    • Journal of Magnetics
    • /
    • 제21권2호
    • /
    • pp.298-302
    • /
    • 2016
  • In bone density examinations, a change in the measured BMD occurs owing to the differences between the measured areas. To address this problem, we aimed to develop a new auxiliary device that could be rotated by $15^{\circ}$ by fixing the ankle to the distal femur neck. Dual energy X-ray absorptiometry (DXA) of BMD examinations were performed once a year, but 10 patients were examined over three sessions to analyze the area for measuring the femur neck BMD. The goal of this test was to determine the device's reliability, and the results were expressed in terms of the standard deviation of measurements. After performing bone density measurements using the new auxiliary device on 10 normal patients, with three measurements for each patient, the obtained standard deviation was 0.03. The standard deviation of the measured BMD was 0.19 when using the currently existing auxiliary device, while the standard deviation of the measured BMD was 0.03 when using the new auxiliary device. By using the new auxiliary device, the standard deviation could be reduced by ~80%. Accurate rotation of the femur neck was possible in all examinations, and the standard deviation of BMD measurements could be reduced by up to 80% compared with the measurements performed using the currently existing auxiliary device. We hope that this advantageous new design can be used as a standard auxiliary device for measuring the femur neck BMD.

막구조물의 막장력 측정장치 개발에 관한 연구 (DEVEOPMENT OF MEASURING SYSTEM OF MEMBRANE STRESS FOR MEMBRANE STRUCTURE)

  • 정한목;우재원;조병욱;이성연
    • 한국공간구조학회:학술대회논문집
    • /
    • 한국공간구조학회 2008년도 춘계 학술발표회 논문집
    • /
    • pp.171-178
    • /
    • 2008
  • This paper is concerned with the development of a measurement system using field measuring device which will give the membrane stress of the membrane structures. Up to this point, several techniques on measurement of membrane stresses has been proposed and some have been used in the fields, but accuracy of the measured stresses to be far from reliable one. Such situation has not been changed until recent days, we do not have the measurement device on which we can depend. On top of that, due to the different properties in cross directions for material of the membrane, the stress in the warp direction is different from that in the fill one. A new method is proposed to measured membrane stresses in two different direction separately, where instead of membrane stresses directly, an external force perpendicular to the membrane to be applied. A portable device can measure the applied force and the displacement. A special testing bed to be fabricated to accommodate $50cm{\times}50$ manbrane specimen which can apply 5 ton load in two orthogonal direction. A special device using push-pull gage was developed. To measure the membrane stresses in warp and fill direction separately, a different length of the tips are used. The measuring device which can called tension meter, can be calibrated on the testing bed, and optimized the length and shape of tip.

  • PDF

수송 기술에 적합한 학습용 풍동의 힘 측정 장치 개발 (Development of Force Measuring Device in Learning Wind Tunnel Used for Transportation Technology Class)

  • 최준섭;이성구
    • 대한공업교육학회지
    • /
    • 제32권1호
    • /
    • pp.117-133
    • /
    • 2007
  • 이 연구는 중등학교 학생들에게 비행의 원리를 이해하고 항공 기술 분야에 흥미를 가질 수 있도록 하기 위해 학교 현장에 적용 가능한 교수-학습 자료인 학습용 풍동의 힘 측정 장치를 개발하였다. 연구의 내용은 학습용 풍동의 힘 측정 장치 개발과 실험으로 이루어져 있다. 이 연구에서 얻은 주요 결과를 정리하면 다음과 같다. 공과대학 기계계열 학과나 항공연구소 등에서 사용하는 고가의 Load cell을 이용한 장치 대신에 지렛대 원리를 활용한 간단한 구조이다. 종합된 하나의 장치로 양력, 항력 및 유체 저항 비교 실험이 가능하다. 에어포일 받음각에 따른 양력 계수는 실험값과 이론값이 전체적으로 비슷한 경향성을 갖으며, 실속 현상은 실험값이 이론값보다 더 큰 받음각에서 나타났다. 에어포일 받음각에 따른 항력 계수는 실험값과 이론값이 전체적으로 비슷한 경향성을 갖으며, 실험값은 이론값에 비해 항력 계수의 증가 비율이 완만하게 증가하였다.

재활환자를 위한 IoT 기반의 실시간 모니터링이 가능한 ROM 측정 장치 개발 (Development of ROM Measurement Device capable of IoT-based Real-time Monitoring for Rehabilitation Patients)

  • 강민수
    • 한국인터넷방송통신학회논문지
    • /
    • 제18권4호
    • /
    • pp.111-116
    • /
    • 2018
  • 본 논문에서는 관절 각도계를 사용하여 관절가동범위의 측정하던 것을 각도계를 사용하지 않고 플렉서블 센서를 이용하여 측정하고 측정된 값을 스마트 디바이스와 연동하여 실시간 모니터링이 가능하게 하였다. 현재의 관절가동 범위 측정은 관절 각도기를 활용하여 사람이 직접 측정하고 있다. 이러한 방법은 측정하는 사람의 측정 방법과 위치에 따른 오류로 일관성 있는 측정이 어려워 오차가 발생할 수 있다. 그래서 측정해야 할 관절에 센서를 부착하여 관절의 운동 범위를 측정하였다. 측정을 위한 센서는 플랙서블 형태로 관절의 움직임에 따라 변화되는 저항 값을 측정하는 센서로서 센싱 된 값을 ROM 센서노드를 통하여 무선으로 스마트 디바이스로 전송될 수 있도록 하였다. 개발 된 ROM 측정 장치는 일반적인 관절 각도기를 활용한 측정보다 일관성 있는 측정이 이루어 질 수 있고 스마트 디바이스와 연동하여 실시간 모니터링 함으로써 관절의 움직임에 따른 신속한 진단으로 환자의 빠른 치료와 재활의료 발전에 도움이 될 것이다.

방사선 펄스의 고안정 계측회로 설계 (Design of a High Stable Measuring Circuit for Radioactive Pulses)

  • 송재용;한주섭;천상규;길경석
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2000년도 추계종합학술대회
    • /
    • pp.577-580
    • /
    • 2000
  • The aim of this paper is to develop a high stable measuring device for radioactive pulses. The device consists of a high voltage supply unit using a fly-back converter principle, and a pulse detection unit for gamma-rays and neutrons. The high voltage supply unit designed can generate DC voltage up to 1,500v at 5V-input, and have a series voltage regulator to maintain the output voltage constantly, resulting in less than 1.63% of voltage regulation. The pulse detection parts consists of an active integrator, a pole-zero circuit, and a 3-stage amplifier of 60 dB, and its frequency bandwidth is from 37 Hz to 300 kHz. From the experimental results, it is confirmed that the measuring device can count at least 10,000 pulses in a second.

  • PDF