Abstract
In this thesis, the range of motion of the joint was measured using a flexible sensor without using a goniometer, and the measured values were transferred to a smart device. Current range of joint motion measurement is measured by a person using a goniometer. Since the method of measuring by a person is different according to the measuring method and position of the measuring person, it is difficult to make consistent measurement, and an error may occur. The sensor for measurement is a flexible sensor that measures the resistance value that changes according to the movement of the joint. The sensed value can be transmitted to the smart device wirelessly through the ROM sensor node. Also, the sensed analog values were converted to digital values using an ADC. The converted value can be transmitted to the smart device wirelessly through the sensor node. The developed ROM measuring device can perform more consistent measurement than the measurement using general articulator and real time monitoring by interlocking with smart device, so that rapid diagnosis according to the movement of the joint can help the patient's rapid treatment and rehabilitation medical advancement will be.
Keywords
ROM(Range of Measurement); IoT; Rehabilitation Medicine; Sensor node; Flexible sensor;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 Spilker B. Introduction. In: Spilker B, editor, Quality of life and pharmacoeconomics in clinical trials. 2nd ed. pp. 1-10, Philadelphia, Lippincott-Raven, 1996.
2 Ji Won Kim, Byung-Kyu Lee, Jeong-Hwa Hong, and Gwang Moon Eom, The Trend and Prospect of Silver/Rehabilitation Engineering, KIC News, Volume 11, No. 2, pp.11-23, 2008.
3 Wan-Sung Hong, Gi-Won Kim Reliability of measurement devices for measuring the ankle joint motion, pp.1-8, vol.1. no.5, Korean J Orthop Manu Ther, 2009
4 Y. J. MOON, S. H. LEE, J. H. BACK, J. K, LEE, K. B. LEE. The development of posture evaluation and Range of Motion(ROM) system by using digital vision analysis method. Korean Journal of Sport Biomechanics, Vol. 14, No. 3, pp. 49-65, 2004.   DOI
5 Megan M. Konor, Sam Morton, Joan M. Eckerson, and Terry L. Grindstaff, "Reliability of Three Measures of Ankle Dorsiflexion Range of Motion", Int J Sports Phys Ther. vol. 7, no.3, pp.279-287, 2012.
6 Taegyun Yun, Gwan-Su Yi, "The transactions of The Korean Institute of Electrical Engineers", vol.57 no.6, pp.1058-1062, 2008.
7 Kang, Min-Hyeok, Yoon, Ji-Yeon, Yang, Jae-Lak, Jang, Jun-Hyeok, Jung, Doh-Heon, Oh, Jae-Seop,"The Effect of Visual Biofeedback on EMG Activity of Trunk Muscles and Endurance Holding Time for Correct Position During Whole-Body Tilt Exercise",Vol.18, No.1,pp.9-17, 2011.
8 Lee, Hyeon-Jae; Lee, Houn-Taek; Shin, Hyun-Sik, "A Study On Ubiquitous Sensor Network Technologies", The Korea Institute of Electronic Communication Science, Volume 4, Issue 1, pp.70-77, 2009.
9 Min-Soo Kang, Chunhwa Ihm, Yong-Gyu Jung, Minho Lee, "Development of IoT-based real-time Toxic Chemical management System", The Journal of The Institute of Internet, Broadcasting and Communication. Vol. 16 No. 5, pp.143-149, 2016. DOI:http://dx.doi.org/10.7236/JIIBC.2016.16.5.143   DOI
10 SoonHyun Kwon, Dongwan Park, Hyochan Bang, Youngtack Park,"Real-time and Parallel Semantic Translation Technique for Large-Scale Streaming Sensor Data in an IoT Environment", Journal of KIISE, Vol. 42, No. 1, pp. 54-67, 2015.   DOI
11 Luis M. Borges, Norberto Barroca, Fernando J. Velez "Smart-clothing wireless flex sensor belt network for foetal health monitoring Sign In or Purchase", Pervasive Computing Technologies for Healthcare, 2009. Pervasive Health 2009. 3rd International Conference on IEEE, 2009, pp.1-4, DOI:10.4108/ICST.PERVASIVE HEALTH2009.6028   DOI
12 Tien Manh Nguyen, Jae-Young Chung,"Analysis and fabrication of a wearable antenna using conductive fibers", Journal of the Korea Academia-Industrial cooperation Society, Vol. 16, No. 4 pp. 2770-2776, 2015. DOI:http://dx.doi.org/10.5762/KAIS.2015.16.4.2770   DOI
13 Min So Kang, Min Ho Lee, Eun So Choi, Jihyung Yoo," Development of ROM(Range of Motion) Module with Improved Accuracy", The 4th International Integrated (Web & Ofline) Conference & Concert on Convergence with Academic, pp.234-237, 2018