• Title/Summary/Keyword: Measurement equipment

Search Result 1,718, Processing Time 0.03 seconds

Store Module Case Study of Traditional Market (전통시장 점포모듈 사례분석 연구)

  • Lee, Kyung-Sik;You, Yen-Yoo;Kim, Jung-Ryol
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.8
    • /
    • pp.255-265
    • /
    • 2017
  • The study analyzed previous studies on traditional markets and market modernization projects to analyze research trends and content related to traditional markets. Next, the study selected 4 traditional markets throughout the nation where there was promotion of market modernization projects to conduct field research and interviews about store modules, line of flow, facility configuration, and types of businesses. Empirical comparative analysis was conducted on construction hardware status through measurement and observation and data was collected on business environment and requirement characteristics by business type through interviews with merchant associations of the corresponding markets. Consistent standard was applied as much it was possible to comparatively analyze the 4 market modernization cases and on the unique characteristics of individual markets, the cause was determined in conjunction to the history of the business promotion process and regional characteristics. After the study, basic data to suggest guidelines in store modules by business type in traditional markets could be acquired and the study identified the facilities equipment standards that must be considered in future market modernization projects. Through this it will be possible to derive policy implications to minimize trial and error and guarantee business efficiency in future market modernization projects.

A study on practice of obesity control by school nurses (보건교사의 비만관리실태 조사연구)

  • Ju, Hyun-Ok;Song, Mi-Gyoung
    • Journal of the Korean Society of School Health
    • /
    • v.15 no.2
    • /
    • pp.249-261
    • /
    • 2002
  • This study was a research study to find out the real picture and practice of student obesity control by primary, middle and high school school nurses. The study sampled 196 school nurses working in the Busan City and Northern Gyungsang Province, who agreed on the purpose of the study. When it comes to the study process, at the meeting of the whole school nurses, the researcher explained the purpose of the study and asked them to complete questionnaires and return on the spot. The study is designed to provide basic data for school nurses in field to systematically and efficiently control student obesity by examining perception of school obesity control and the real picture or practice of obesity control as well as its problems. The study used SPSS 10.0 to analyze data. The results are as follows: Annual plans about obesity control appeared significant at the primary school, 89.3%, higher than 77.3% of the middle and high school(p<0.05). Annual project evaluation showed a significant difference by regions, 56.0% of metro cities vs. small cities(p<0.01). The number of measuring weight of obese students was higher at the primary school than at the middle and high school(p<0.05). Also small cities conducted the weight measurement more often than metro cities(p<0.001). Among the health education methods for obesity, counseling appeared statistically significant(p<.01). The health education showed a significant difference in more experienced school nurses. Among the educational media, environment postings were used at the primary school, 24.0%, higher than 5.3% of the middle and high school. It showed a significant difference(p<.001). OHP or epidiascopes were used at the primary school, 36.4%, significantly higher than the middle and high school(p<.001). In addition, computer was used at the primary school, 21.5%, higher than the middle and high school(p<.05). Problems of obesity education data included a lack of textbooks and programs and a short of educational media. However it didnt show a significant difference in schools or in regions. Counseling activities for obesity showed a significant difference in schools(p<.01) and in regions(p<.001). When parents with obese students were in counseling, those in their 20s used home correspondence and those in their 30s and 40s used phone call(p<.01). The rate of equipment to measure obesity was higher at the middle and high school than the primary school, showing a significant difference(p<.001). Therefore, regular health education curriculums for school nurses should be systematically created to promote student health. Furthermore, it needs to make standard textbooks for health education by grades as well as by levels and to develop various educational programs and educational media.

A Study on the Relation Characteristics between Bubble Size Distribution and Floating Time (버블의 크기별 입도분포와 부상시간과의 상관특성에 관한 연구)

  • Jeon, Gun;Park, Chul-Hwi
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.5
    • /
    • pp.277-281
    • /
    • 2017
  • Lately rainfall characteristics that it rains a lot in a short space of time often occurs. Because of this meteorological phenomena, the flow rate and concentration of initial rainfall for runoff and combined sewer overflows are changed. In the case of this inlet fluctuation, the flotation method at high surface loading rate is suitable for water quality management. the flotation method is able to meet the removal rate requirements of water public zone in 5 to 10 min which is irelatively short period. For assessment and diagonision of flotation method, A/S ratio is applied until now. But unfortunately, this has some limits for evaluation standard for certification and assessment of technical diagnosis and operation. This is why there is different efficiency in the bubble distribution at the same A/S ratio. The velocity and time of floating is changed by the different bubble distributions. The floating time affects the plant volume because the time factor make size dicision. Therefore the charateristics of bubble distribution and floating time at the same A/S ratio is necessary to apply to evaluation standard for certification and assessment of technical diagnosis and operation. For generalization of the method in certification and assessment, the characteristics of bubble distribution was studied. Until recently, using the optical device and shooting live video, there are some analysis technology of the floating factors. But this kind of technology is influenced by the equipment. with this level of confidence about the results, it is difficult to apply to generalize. According this reasons, this study should be applied on experiment generalization of method about measurement of relation between bubble distribution and floating time.

Measurement of Journal Bearing Friction Loss of Turbocharger in a Passenger Vehicle (승용차용 터보과급기의 저널 베어링 마찰 손실 측정)

  • Chung, in-Eun;Jeon, Se-Hun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.7
    • /
    • pp.9-15
    • /
    • 2018
  • The turbochargers, which are used widely in diesel and gasoline engines, are an effective device to reduce fuel consumption and emissions. On the other hand, turbo-lag is one of the main problems of a turbocharger. Bearing friction losses is a major cause of turbo lag and is particularly intense in the lower speed range of the engine. Current turbochargers are mostly equipped with floating bearings: two journal bearings and one thrust bearing. This study focused on the bearing friction at the lower speed range and the experimental equipment was established with a drive-motor, load-cell, magnetic coupling, and oil control system. Finally, the friction losses of turbochargers were measured considering the influence of the rotating speed from 30,000rpm to 90,000rpm, oil temperature from $50^{\circ}C$ to $100^{\circ}C$, and oil supply pressure of 3bar and 4bar. The friction power losses were increased exponentially to 1.6 when the turbocharger speed was increased. Friction torques decreased with increasing oil temperature and increased with increasing oil pressure. Therefore, the oil temperature and pressure must be maintained at appropriate levels.

Correlation between Probe Frequency and Echo-Pulse Velocity for Ultrasonic Testing of a Fiber-Reinforced Plastic Hull Plate (복합소재 선체 외판의 초음파 탐상을 위한 탐촉자 주파수와 수신기 음향 속력의 상관관계)

  • Lee, Sang-gyu;Han, Zhiqiang;Lee, Chang-woo;Oh, Daekyun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.26 no.2
    • /
    • pp.219-226
    • /
    • 2020
  • Nondestructive testing is one of the most commonly used quality inspection methods for evaluating ship structures. However, accurate evaluation is dif icult because various composite materials, such as reinforcements, resin, and fiber-reinforced plastics (FRPs), are used in hulls, and manufacturing quality differences are likely to exist owing to the fabrication environment and the skill level of workers. This possibility is especially true for FRP ships because they are significantly thicker than other structures, such as automobiles and aircraft, and are mainly manufactured using the hand lay-up method. Because the density of a material is a critical condition for ultrasonic inspection, in this study, a hull plate was selected from a vessel manufactured using e-glass fiber, which is widely used in the manufacture of FRP vessels with the weight fraction of the glass content generally considered. The most suitable ultrasonic testing conditions for the glass FRP hull plate were investigated using a pulse-echo ultrasonic gauge. A-scans were performed with three probes (1.00, 2.25, and 5.00 MHz), and the results were compared with those of the hull plate thickness measured using a Vernier caliper. It was found that when the probe frequency was higher, the eco-pulse velocity of the receiver had to be lowered to obtain accurate measurement results, whereas fewer errors occurred at a relatively low probe frequency.

Relationship between the depth of cingulate sulcus on neonatal high resolution cranial ultrasound and gestational age (신생아 고해상 뇌 초음파검사에서 대상고랑의 깊이와 재태기간과의 관계)

  • Choi, Young Chil;Choi, Jin Yong;Lee, Jung Hwa
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.10
    • /
    • pp.1136-1139
    • /
    • 2009
  • Purpose:It is critical that the exact gestational age of a newborn baby, especially premature baby, be determined to evaluate the status of a disease and its management and to estimate the prognosis of a patient. This study aimed to investigate an easy and accurate method to estimate gestational age on cranial ultrasound, requiring minimal additional time and equipment. Methods:A high-resolution coronal sonographic image was obtained via the anterior fontanel with a 5-12 Mhz linear probe after the usual cranial sonographic examination. We measured the depth of cerebral hemisphere, thickness of corpus callosum, and depth of cingulate sulcus and obtained the correlations between these factors and gestational age. Results:Depth of cingulate sulcus had the highest correlation coefficiency with gestational age (r=0.878, P=0.000). All the cases, except for 2 cases, had a gestational age of more than 37 weeks, when the depths of cingulate sulcus were more than 0.55 cm, and had a gestational age less than 34 weeks, when the depths of cingulate sulcus were less than 0.35 cm. Conclusion:Measurement of the depth of cingulate sulcus was a simple and accurate method to estimate the gestational age on cranial ultrasound. The gestational age is more than 37 weeks, when the depth of cingulate sulcus is more than 0.55 cm, and is less than 34 weeks, when the depth of cingulate sulcus is less than 0.35 cm.

Development of Friction Loss Measurement Device at Low Speed of Turbocharger in a Passenger Vehicle (승용차용 터보과급기의 저속 영역 마찰 손실 측정 장치 개발)

  • Chung, Jin Eun;Lee, Sang Woon;Jeon, Se Hun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.1
    • /
    • pp.585-591
    • /
    • 2017
  • Turbocharging is widely used in diesel and gasoline engines as an effective way to reduce fuel consumption. But turbochargers have turbo-lag due to mechanical friction losses. Bearing friction losses are a major cause of mechanical friction losses and are particularly intensified in the lower speed range of the engine. Current turbochargers mostly use oil bearings (two journal bearings and one thrust bearing). In this study, we focus on the bearing friction in the lower speed range. Experimental equipment was made using a drive motor, load cell, magnetic coupling, and oil control system. We measured the friction losses of the turbocharger while considering the influence of the rotation speed, oil temperature, and pressure. The friction power losses increased exponentially when the turbocharger speed increased.

The Effects of Slide-Covered of Slide-Covered Contemporary Charging Automated External Defibrillator on Rapidity and Convenience of Defibrillation (슬라이드 커버 동시충전 자동심장충격기가 제세동의 신속성과 편의성에 미치는 효과)

  • Park, Si-Eun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.8
    • /
    • pp.325-333
    • /
    • 2020
  • This study compares the rapidity and subjective convenience of T-AED and SC-AED for health care providers and the general public. Subjects were randomly allocated to T-AED (n=77) and SC-AED (n=79) groups. Each group conducted defibrillation, with subsequent measurement of the rapidity of defibrillation in peri-shock pause, pre-shock pause, hesitation pause, and post-shock pause. Defibrillation and chest compression delay times for both equipment were analyzed by t-test. On conclusion of the experiment, subjects answered a questionnaire on the subjective convenience of defibrillation, as measured for confidence, convenience, and clear decision. Comparisons of subjective convenience analyzed by t-test revealed significantly shortened peri-shock pause (11.22s), pre-shock pause (11.04s), and hesitation pause (2.15s) in the SC-AED group, as compared to the T-AED group (p<0.001). However, no significant differences were observed for post-shock pause values. Comparing subjective convenience, confidence (T-AED: 7.62±1.25VAS vs. SC-AED: 7.80±0.98VAS, p=0.358) was not significant, whereas convenience (T-AED: 7.05±1.36VAS vs. SC-AED: 8.95±0.89VAS, p<0.001) and clear decision (T-AED: 6.58±1.73VAS vs. SC-AED: 9.08±0.98VAS, p=0.001) showed statistically significant differences. Our results indicate that compared to T-AED, SC-AED has significantly shortened pauses. Moreover, it is more convenient for the user, and significantly aids in clear decisions.

A comparison of bladder volume by sonogram and CBCT for Pelvic region cancer (골반부 암 치료 시 초음파검사를 통한 방광체적과 CBCT영상 방광체적의 비교)

  • Son, Seong Ho;Park, Ha Ryung;Baek, Jung Jin;Son, Jong Ki;Choi, Min Ho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.2
    • /
    • pp.7-12
    • /
    • 2019
  • Purpose: During the pelvic radiation therapy, it is performed with controlling bladder volume because the range of irradiation is changed depending on the bladder volume. Therefore in this study, we evaluate the accuracy of BVI by tracing the change of bladder volume using ultrasonic pulse diagnosis equipment(BVI 6100, Medical supply Co. LTD) Material and Methods: From January 2017 to September 2018, 19 patients who received pelvic radiation therapy at Pusan National University Hospital were included. To treat the patient, we compared that the bladder volume obtained from the BVI and the bladder volume obtained from the CBCT image then we evaluated for significance. Results: There was a significant correlation of r=0.773, BVI and CBCT in the whole volume section. However, based on the bladder volume in the RTP Image the p value was shown to be 0 at 125~175cc and lower than 0.05 at 175~275cc, And more than 0.05 at 275~375cc. Conclusions: In this study, the patient whose bladder volume is above than 275cc, there is a significance of bladder volume between BVI and CBCT image. However, we could make a decision to be undermined the reliability of BVI measurement in the case of the patient with emptied his urine. Therefore, it is possible to acquire a significant value for 175~275cc patients to use the correction value of BVI and the appropriate tolerance of volume.

Application of ATP Bioluminescence Assay for Measurement of Microbial Contamination in Fresh-cut Produce Processing Lines (신선편이 농식품 생산라인의 환경미생물 오염도 측정을 위한 ATP 검사법의 이용)

  • Choi, Ji-Weon;Lee, Hye-Eun;Kim, Chang-Kug;Kim, Won-Bae;Kim, Ji-Kang
    • Food Science and Preservation
    • /
    • v.19 no.1
    • /
    • pp.62-66
    • /
    • 2012
  • With the rapid growth of fresh-cut produce market, the South Korean fresh-cut industry is facing the challenge of ensuring food safety. As the estimation of the microbial numbers in fresh-cut produce processing lines (tools, and equipment) using the conventional microbiological techniques takes days, so there is a need for faster and easier monitoring methods. This study was conducted to investigate the use of ATP bioluminescence assay to measure the degree of microbial contamination from three actual fresh-cut processing lines. The samples collected from frech-cut vegetables, and fresh-cut fruits processing plants were tested for the estimation of the bacterial number, using the ATP bioluminescence and microbiological methods. The result of former was transferred to log RLU/100 $cm^2$, and that of the latter was transferred to log CFU/100 $cm^2$. A positive linear correlation between the ATP bioluminescence assay value and aerobic-plate count was found for fresh-cut processing lines, with a correlation coefficient of 0.8772 (n=50). The results of this study indicate that ATP bioluminescence assay can be used to monitor microbial contamination in fresh-cut produce processing plants, and can help improve the hygiene therein.