Abstract
With the rapid growth of fresh-cut produce market, the South Korean fresh-cut industry is facing the challenge of ensuring food safety. As the estimation of the microbial numbers in fresh-cut produce processing lines (tools, and equipment) using the conventional microbiological techniques takes days, so there is a need for faster and easier monitoring methods. This study was conducted to investigate the use of ATP bioluminescence assay to measure the degree of microbial contamination from three actual fresh-cut processing lines. The samples collected from frech-cut vegetables, and fresh-cut fruits processing plants were tested for the estimation of the bacterial number, using the ATP bioluminescence and microbiological methods. The result of former was transferred to log RLU/100 $cm^2$, and that of the latter was transferred to log CFU/100 $cm^2$. A positive linear correlation between the ATP bioluminescence assay value and aerobic-plate count was found for fresh-cut processing lines, with a correlation coefficient of 0.8772 (n=50). The results of this study indicate that ATP bioluminescence assay can be used to monitor microbial contamination in fresh-cut produce processing plants, and can help improve the hygiene therein.
신선편이 농식품 시장의 빠른 성장과 함께 안전관리기준도 강화되고 있어 제조 시설 현장에서 신속하고 간편하게 위생상태를 판단할 수 있는 모니터링기법이 필요하게 되었다. 본 연구는 신선편이 농식품 생산업체 3개소를 대상으로 생산에 사용되는 도구와 기기에 대한 미생물수를 조사하였고 그에 대한 검증법인 ATP 검사법의 상관관계를 도출하고자 하였다.신선편이 농식품 생산업체 3개소의 신선편이 가공 시설, 장비에서 채취된 총 50개 시료의 ATP bioluminescence assay 값과 일반세균수와의 상관계수 (r)은 0.8772로 나타났다. ATP 검사법은 신속, 간편, 일관성을 바탕으로 신선편이 농식품 산업체에서 미생물 배양법을 대체하여 위생 환경 개선에 유용하게 쓸 수 있는 것으로 판단된다.