• 제목/요약/키워드: Measurement Standard

검색결과 3,512건 처리시간 0.029초

공압밸브의 동적응답 특성측정 자동화 시스템 개발 (Development of automatic measurement system for dynamic respose time of pneumatic solenoid valve)

  • 강보식;김형의
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1991년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 22-24 Oct. 1991
    • /
    • pp.974-978
    • /
    • 1991
  • Electro-pneumatic valve is an electro-mechanical device which converts electric signal into pneumatic flow mu or pressure. A measurement of dynamic response time is very important to evaluate valve performance. Dynamic response time of electro-pneumatic valve has a variation accordance with valve types, operating way and test standard. In this study, automatic measurement system of dynamic response time is composed based on test condition of dynamic response time test standard(CETOP, JIS). Also, in this study test pressure variation characteristics accordance with variation of solenoid excitation power, and we developed dynamic response measurement system enable to compare of and analyze these two characteristics.

  • PDF

비정규 측정오차의 경우 측정시스템 변동과 PTR 추정 (Estimations of Measurement System Variability and PTR under Non-normal Measurement Error)

  • 장무성;김상부
    • 한국품질경영학회:학술대회논문집
    • /
    • 한국품질경영학회 2006년도 추계 학술대회
    • /
    • pp.199-204
    • /
    • 2006
  • ANOVA is widely used for measurement system analysis. It assumes that the measurement error is normally distributed, which may not be seen in some industrial cases. In this study, the estimates of the measurement system variability and PTR (precision-to-tolerance ratio) are obtained by using weighted standard deviation for the case where the measurement error is non-normally distributed. The Standard Bootstrap method is used for estimating confidence intervals of measurement system variability and PTR. The point and confidence interval estimates for the cases with normally distributed measurement error are compared to those with non-normally distributed measurement errors through computer simulation.

  • PDF

버어리종 담배 중 질산성 질소에 대한 측정불확도 (Uncertainty of Measurement in Nitrate Analysis from Burley Leaf Tobacco)

  • 이정민;이경구;한상빈
    • 한국연초학회지
    • /
    • 제27권2호
    • /
    • pp.226-234
    • /
    • 2005
  • The uncertainty of measurement in nitrate from burley leaf tobacco by continuous-flow analysis method was evaluated following internationally accepted guidelines. The sources of uncertainty associated with the analysis of nitrate were weight of standard and sample, purity of standard, dilution of standard solution, calibration curve, water content, etc. The calculation of uncertainty based on the GUM(Guide to the Expression of Uncertainty in Measurement) and EURACHEM/CITAC Guide. An expanded uncertainty was obtained by multiplying the combined standard uncertainty with a coverage factor (k) calculated from the effective degree of freedom. The concentration of nitrate from burley leaf tobacco was $2.09\%$ and the expanded uncertainty by multiplying by the coverage factor(k, 2.20) was $0.13\%\;at\;a\;95\%$ confidence level.

파이프 프루버의 측정불확도에 관한 연구 (A Study on the Measurement Uncertainty of Pipe Prover)

  • 임기원
    • 대한기계학회논문집B
    • /
    • 제24권10호
    • /
    • pp.1388-1398
    • /
    • 2000
  • A pipe prover is a flowmeter calibrator used in flow measurement field. Gravimetric and volumetric methods were applied to determine the basic volume of the pipe prover. Uncertainty of its basic volume measurement was evaluated in accordance with the procedure recommended by International Organization for Standardization. The combined standard uncertainty of determining the basic volume was estimated from the sensitivity coefficient and the standard uncertainty of independent variables. It was found that the uncertainties of the weighing and volume measurements have dominant influence on that of the basic volume determination. With the quantitative analysis of the sensitivity coefficient, the contribution of the each variable uncertainty to the combined standard uncertainty of the basic volume is shown clearly.

소음기 감음 성능 불확도 산출 방법 연구 (Application of the uncertainty for insertion loss measurement of silencers)

  • 유승국;김대현;김영찬;김두훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.1675-1680
    • /
    • 2000
  • Recently the uncertainty has been made rapid progress in various fields of industry but the uncertainty measurement method of acoustical test (i.e. Insertion loss, Absorption ratio, Transmission loss etc,) hasn't been established. In this study, the uncertainty of measurement method for ducted silencers is carried out according to ISO 7235. The standard uncertainty factors are composed of sound pressure level, microphone sensitivity and pistonphone calibration in this measurement. Sound pressure level is type A evaluation of uncertainty, microphone sensitivity and pistonphone calibration are type B evaluation of uncertainty. The combined standard uncertainty is calculated by two type evaluation. The expanded uncertainty is expressed by the combined standard uncertainty multiply k value which is yield the effective degree of freedom.

  • PDF

$4{\sim}6$세 유아의 무게 측정전략 발달에 관한 연구 (Strategies Used by Young Children in Weight Measurement Tasks)

  • 이보영;김주영
    • 대한가정학회지
    • /
    • 제45권7호
    • /
    • pp.49-60
    • /
    • 2007
  • The purpose of this study was to analyze the weight measurement tasks according to children's ages and whether 4-to 6-year-old children use proper measurement equipment to measure weight. The study subjects were 105 preschool children: 37,38, and 30 4-, 5-, and 6-year-old children, respectively. The results showed that young children use 3 to 4 strategies. They used a strategy to estimate objects visually on the first step in measurement by direct comparison. On the second step, in measurement by nonstandard unit, they held up objects with one hand or two hands. That is, two strategies were shown in measuring objects with hands in this second step. On the third step, which is measured by standard unit, they used a strategy to choose the equal arm balance out of suggested measurement equipment.

Uncertainty assessment for a towed underwater stereo PIV system by uniform flow measurement

  • Han, Bum Woo;Seo, Jeonghwa;Lee, Seung Jae;Seol, Dong Myung;Rhee, Shin Hyung
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제10권5호
    • /
    • pp.596-608
    • /
    • 2018
  • The present study aims to assess test uncertainty assessment method of nominal wake field measurement by a Stereoscopic Particle Image Velocimetry (SPIV) system in a towing tank. The systematic uncertainty of the SPIV system was estimated from repeated uniform flow measurements. In the uniform flow measurement case, time interval between image frames and uniform flow speed were varied to examine the effects of particle displacement and flow around the SPIV system on the systematic standard uncertainty. The random standard uncertainty was assessed by repeating nominal wake field measurements and the estimated random standard uncertainty was compared with that of laser Doppler velocimetry. The test uncertainty assessment method was applied to nominal wake measurement tests of a very large crude oil carrier model ship. The nominal wake measurement results were compared with existing experimental database by other measurement methods, with its assessed uncertainty.

길이 소급성을 갖는 AFM을 이용한 150nm 피치 측정 (150 nm Pitch Measurement using Metrological AFM)

  • 진종한
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.264-267
    • /
    • 2003
  • Pitch measurements of 150 nm pitch one-dimensional grating standards were carried out using an contact mode atomic force microscopy(C-AFM) with a high resolution three-axis laser interferometer. It was called as 'Nano-metrological AFM' In Nano-metrological AFM, Three laser interferometers were aligned well to the end of AFM tip. Laser sources of the three-axis laser interferometer in the nano-metrological AFM were calibrated with an I$_2$-stablilzed He-Ne laser at a wavelength of 633 nm. So, the Abbe error was minimized and the result of the pitch measurement using the nano-metrological AFM has a traceability to the length standard directly. The uncertainty in the pitch measurement was estimated in accordance with the Guide to the Expression of Uncertainty in Measurement(GUM). The Primary source of uncertainty in the pitch-measurements was derived from repeatability of pitch-measurement, and its value was approx 0.186 nm. Expanded uncertainty(k=2) of less than 5.23 nm was obtained. It is suggested that the metrological AFM is a useful tool for the nano-metrological standard calibration.

  • PDF

Pitch Measurement of 150 nm 1D-grating Standards Using an Nano-metrological Atomic Force Microscope

  • Jonghan Jin;Ichiko Misumi;Satoshi Gonda;Tomizo Kurosawa
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제5권3호
    • /
    • pp.19-25
    • /
    • 2004
  • Pitch measurements of 150 nm one-dimensional grating standards were carried out using a contact mode atomic force microscopy with a high resolution three-axis laser interferometer. This measurement technique was named as the 'nano-metrological AFM'. In the nano-metrological AFM, three laser interferometers were aligned precisely to the end of an AFM tip. Laser sources of the three-axis laser interferometer in the nano-metrological AFM were calibrated with an I$_2$ stabilized He-Ne laser at a wavelength of 633 nm. Therefore, the Abbe error was minimized and the result of the pitch measurement using the nano-metrological AFM could be used to directly measure the length standard. The uncertainty in the pitch measurement was estimated in accordance with the Guide to the Expression of Uncertainty in Measurement (GUM). The primary source of uncertainty in the pitch-measurements was derived from the repeatability of the pitch-measurements, and its value was about 0.186 nm. The average pitch value was 146.65 nm and the combined standard uncertainty was less than 0.262 nm. It is suggested that the metrological AFM is a useful tool for the nano-metrological standard calibration.

성인여자 기성복의 치수실태에 관한 조사연구 (A Study on the Problems of Domestic Women Size in the Ready-Made Clothing)

  • 공민희
    • 대한가정학회지
    • /
    • 제20권1호
    • /
    • pp.23-36
    • /
    • 1982
  • The purpose of this study was to investigate the problems of consumer and producer in women's ready-made clothing through questionaires, and to solve the problems presented by questionaires. The point at problems of ready-made clothing indicated by the consumer and producer altogether focused on the size. Therefore this study on the size of ready-made clothing was carried out. The size selected for the research materials were producer's size, domestic researchers' measurement size, KS size in the '81, and foreign standard sizes. The results of this study were as follows: 1) As comparing three kinds of size the producers' size(A), domestic researchers' measurement size(B), and KS size(C) it follows that: ① To the same circumference of bust, the waist measurement showed in following order: B>C>A, and the hip measurement showed generally in following order: A>B. ② The extent of bust measurement showed in following order: B>C>A. ③ The sort numbers of size showed in following order: C>B>A. 2) As Comparing with foreign standard sizes, the sort numbers of our standard size were much less than foreigns as following order: DOB(102)>JIS(78)>BS(39)>PS(29)>KS(15)FNOR(10). 3) The reasonable size was made by referring to the producer's size, researchers' measurement size, and KS size.

  • PDF