• 제목/요약/키워드: Measure

검색결과 31,065건 처리시간 0.052초

Uncertainty in the dempster-shafer Theory - A Critical Re-examination

  • Klir, George J.;Ramer, Arthur
    • 한국지능시스템학회논문지
    • /
    • 제1권2호
    • /
    • pp.4-45
    • /
    • 1991
  • Measures of two types of uncertainty that coexist in the Dempster-Shafer theory are overivewed. A measure of one type of uncertainty, which expresses nonspecificity of evidential claims, is well justified on both intuitive and mathermatical grounds. Proposed measures of the other types of uncertainty, which attempt to capture conflicts among evidential claims, are shown to have some deficiencies. To alleviate these deficiencies, a new measure is proposed. This measure, which is called a measure of discord, is not only satisfactory on intuitive grounds, but has alos desirable mathematical properties. A measure of total uncertainty, which is defined as the sum of nonspecificity and discord, is also discussed. The paper focuses on conceptual issues. Mathematical properties of the measure of idscord are only stated ; their proofs are given in a companion paper.

  • PDF

POSITIVELY WEAK MEASURE EXPANSIVE DIFFERENTIABLE MAPS

  • Ahn, Jiweon;Lee, Manseob
    • 대한수학회보
    • /
    • 제57권3호
    • /
    • pp.569-581
    • /
    • 2020
  • In this paper, we introduce the new general concept of usual expansiveness which is called "positively weak measure expansiveness" and study the basic properties of positively weak measure expansive C1-differentiable maps on a compact smooth manifold M. And we prove that the following theorems. (1) Let 𝓟𝓦𝓔 be the set of all positively weak measure expansive differentiable maps of M. Denote by int(𝓟𝓦𝓔) is a C1-interior of 𝓟𝓦𝓔. f ∈ int(𝓟𝓦𝓔) if and only if f is expanding. (2) For C1-generic f ∈ C1 (M), f is positively weak measure-expansive if and only if f is expanding.

여유자유도 로봇에 있어서 성능지수 제한궤적을 이용한 부작업의 성능에 관한 연구 (A Study on the Subtask Performance Using Measure Constraint Locus for a Redundant Robot)

  • 최병욱;원종화;정명진
    • 전자공학회논문지B
    • /
    • 제28B권10호
    • /
    • pp.761-770
    • /
    • 1991
  • This paper suggests a measure constraint locus for characterization of the performance of a subtask for a redundant robot. The measure constraint locus are the loci of points satisfying the necessary constraint for optimality of measure in the joint configuration space. To uniquely obtain an inverse kinematic solution, one must consider both measure constraint locus and self-motion manifolds which are set of homogeneous solutions. Using measure constraint locus for maniqulability measure, the invertible workspace without singularities and the topological property of the configuration space for linding equilibrium configurations are analyzed. We discuss some limitations based on the topological arguments of measure constraint locus, of the inverse kinematic algorithm for a cyclic task. And the inverse kinematic algorithm using global maxima on self-motion manifolds is proposed and its property is studied.

  • PDF

A New Measure for Monitoring Intraoperative Somatosensory Evoked Potentials

  • Jin, Seung-Hyun;Chung, Chun Kee;Kim, Jeong Eun;Choi, Young Doo
    • Journal of Korean Neurosurgical Society
    • /
    • 제56권6호
    • /
    • pp.455-462
    • /
    • 2014
  • Objective : To propose a new measure for effective monitoring of intraoperative somatosensory evoked potentials (SEP) and to validate the feasibility of this measure for evoked potentials (EP) and single trials with a retrospective data analysis study. Methods : The proposed new measure (hereafter, a slope-measure) was defined as the relative slope of the amplitude and latency at each EP peak compared to the baseline value, which is sensitive to the change in the amplitude and latency simultaneously. We used the slope-measure for EP and single trials and compared the significant change detection time with that of the conventional peak-to-peak method. When applied to single trials, each single trial signal was processed with optimal filters before using the slope-measure. In this retrospective data analysis, 7 patients who underwent cerebral aneurysm clipping surgery for unruptured aneurysm middle cerebral artery (MCA) bifurcation were included. Results : We found that this simple slope-measure has a detection time that is as early or earlier than that of the conventional method; furthermore, using the slope-measure in optimally filtered single trials provides warning signs earlier than that of the conventional method during MCA clipping surgery. Conclusion : Our results have confirmed the feasibility of the slope-measure for intraoperative SEP monitoring. This is a novel study that provides a useful measure for either EP or single trials in intraoperative SEP monitoring.

Quantification of Entire Change of Distributions Based on Normalized Metric Distance for Use in PSAs

  • Han, Seok-Jung;Chun, Moon-Hyun;Tak, Nam-Il
    • Nuclear Engineering and Technology
    • /
    • 제33권3호
    • /
    • pp.270-282
    • /
    • 2001
  • A simple measure of uncertainty importance based on normalized metric distance to quantify the entire change of cumulative distribution functions (CDFs) has been developed for use in probability safety assessments (PSAs). The metric distance measure developed in this study reflects the relative impact of distributional changes of inputs on the change of an output distribution, white most of the existing uncertainty importance measures reflect the magnitude of relative contribution of input uncertainties to the output uncertainty. Normalization is made to make the metric distance measure a dimensionless quantity. The present measure has been evaluated analytically for various analytical distributions to examine its characteristics. To illustrate the applicability and strength of the present measure, two examples are provided. The first example is an application of the present measure to a typical problem of a system fault tree analysis and the second one is for a hypothetical non-linear model. Comparisons of the present result with those obtained by existing uncertainty importance measures show that the metric distance measure is a useful tool to express the measure of uncertainty importance in terms of the relative impact of distributional changes of inputs on the change of an output distribution.

  • PDF

연관성 규칙의 탐색을 위한 순수 대칭적 J 측도의 활용 (Utilizing Purely Symmetric J Measure for Association Rules)

  • 박희창
    • Journal of the Korean Data Analysis Society
    • /
    • 제20권6호
    • /
    • pp.2865-2872
    • /
    • 2018
  • 데이터 마이닝 분야에서 개발된 기법에는 연관성 규칙, 군집분석, 의사결정나무, 신경망 등 여러 가지가 있는데 이들 중에서 연관성 규칙은 지지도, 신뢰도, 그리고 향상도 등 여러 가지 연관성 평가 기준을 이용하여 항목들 간에 특정한 연관성을 탐색하는 기법이다(Park, 2014). 이러한 연관성 규칙은 Agrawal et al.(1993)이 처음 제안하였으며, 그 이후로 여러 연구자들에 의해 연구가 진행되고 있으며, 최근에는 교차 엔트로피와 관련된 연구들이 발표되고 있다(Park, 2016b). 본 논문에서는 기존에 발표된 J 측도에 방향성과 순수성을 고려한 순수 대칭적 J 측도를 제안하고 예제를 활용하여 그 유용성에 대해 알아보았다. 그 결과, 동시발생빈도가 증가함에 따라 순수 대칭적 J 측도가 기존의 J 측도와 대칭적 J 측도, 순수 교차 엔트로피 측도보다 훨씬 분명하게 변하는 것을 알 수 있었으며, 불일치빈도의 크기에 따라서도 순수 대칭적 J 측도가 변화하는 폭이 더 커짐에 따라 연관성 유무를 더 분명하게 파악할 수 있었다. 따라서 순수 대칭적 J 측도는 데이터가 존재하는 어느 분야에서든지 연관성 규칙의 평가에 적용이 가능할 것으로 생각된다.

Three-dimensional Teleoperation Performance Measures: Their correlations and effects of task difficulty

  • Park, Sung Ha
    • 대한인간공학회지
    • /
    • 제19권2호
    • /
    • pp.33-45
    • /
    • 2000
  • Present study was performed to compare different types of teleoperation performance measures. A modified Cooper-Harper rating scale and a distance measure were newly introduced and compared to two traditional measures, the error rate and time-to-completion. Participants performed a simulated telerobotic task with varying visual display interfaces. The results of correlation analyses revealed that the modified Cooper-Harper ratings had a close association with the error rate measure. The distance measure also appeared to be a consistent performance measure, which accounted for both the error rate and time-to-completion. A further analysis, however, showed that the effectiveness of each performance measure varied with the level of task difficulty. The results imply that the choice of performance measure should be made based on the task difficulty as well as the particular task being studied. The results revealed here also have implication for performance measures of various display and control systems including aircraft navigation displays and tactical displays.

  • PDF

Feature extraction with distance measures and fuzzy entropy

  • Lee, Sang-Hyuk;Kim, Sung-Shin;Hyeon Bae;Kim, Youn-Tae
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 2003년도 ISIS 2003
    • /
    • pp.543-546
    • /
    • 2003
  • Representation and quantification of fuzziness are required for the uncertain system modelling and controller design. Conventional results show that entropy of fuzzy sets represent the fuzziness of fuzzy sets. In this literature, the relations of fuzzy enropy, distance measure and similarity measure are discussed, and distance measure is proposed. With the help of relations of fuzzy entropy, distance measure and similarity measure, fuzzy entropy is proposed by the distance measure. Finally, proposed entropy is applied to measure the fault signal of induction machine.

  • PDF

호도법에 관한 교수학적 고찰 (A Didactical Analysis on Circular Measure)

  • 강미광
    • 한국수학교육학회지시리즈A:수학교육
    • /
    • 제50권3호
    • /
    • pp.355-365
    • /
    • 2011
  • The purpose of this study is to provide mathematical knowledge for supporting the didactical knowledge on circular measure and radian in the high school curriculum. We show that circular measure related to arcs can be mathematically justified as an angular measure and radian is a well defined concept to be able to reconcile the values of trigonometric functions and ones of circular functions, which are real variable functions. Radian has two-fold intrinsic attributes of angular measure and arc measure on the unit circle, in particular, the latter property plays a very important role in simplifying the trigonometric derivatives. To improve students's low academic achievement in trigonometry section, the useful advantage and the background over the introduction of radian should be preferentially taught and recognized to students. We suggest some teaching plans to practice in the class of elementary and middle school for enhancing teachers' and students' understanding of radian.