• 제목/요약/키워드: Materials for fire resistance

검색결과 220건 처리시간 0.022초

막재료의 설치높이와 발열량에 따른 화재연소특성 (Fire Combustion Characteristics of Membrane Materials According to the Height and Heat Generation Rate)

  • 조승호;최광호;노영숙
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제20권6호
    • /
    • pp.84-90
    • /
    • 2016
  • 최근 다양한 형태의 막구조물의 건설이 증가추세이지만 막구조물에 적합하지 않은 내화기준이 적용되어 활용성이 위축되고 있는 실정이다. 그렇기 때문에 막구조물의 건설 활성화에 맞추어서 이에 대한 내화기준의 제 개정이 필요한 상황이다. 따라서 본 연구에서는 일반적으로 많이 사용되는 막재료(ETFE, PVF, PTFE)를 선정하여 막구조물에 화재가 일어났을 때, 시간이 변화함에 따라 온도가 올라가는 막재료의 물리적인 특성 변화와 발열량과 막재료 설치높이와의 상관관계를 파악하여 막구조 내화기준에 기초 자료로 활용하고자 한다.

Effect of Fire Induced Spalling on the Response of Reinforced Concrete Beams

  • Kodur, V.K.R.;Dwaikat, M.B.
    • International Journal of Concrete Structures and Materials
    • /
    • 제2권2호
    • /
    • pp.71-81
    • /
    • 2008
  • A macroscopic finite element model is applied to investigate the effect of fire induced spalling on the response of reinforced concrete (RC) beams. Spalling is accounted for in the model through pore pressure calculations in concrete. The principles of mechanics and thermodynamics are applied to compute the temperature induced pore pressure in the concrete structures as a function of fire exposure time. The computed pore pressure is checked against the temperature dependent tensile strength of concrete to determine the extent of spalling. Using the model, case studies are conducted to investigate the influence of concrete permeability, fire scenario and axial restraint on the fire induced spalling and also on the response of RC beams. Results from the analysis indicate that the fire induced spalling, fire scenario, and axial restraint have significant influence on the fire response of RC beams. It is also shown that concrete permeability has substantial effect on the fire induced spalling and thus on the fire response of concrete beams. The fire resistance of high strength concrete beams can be lower that that of normal strength concrete beams due to fire induced spalling resulting from low permeability in high strength concrete.

구조체 보호를 위한 고내화성 마감재 적용에 관한 실험적 연구 (Development of Inorganic Fire Protection Materials for High Strength Concrete)

  • 정석조;송훈;권춘우;김영엽;추용식;이종규
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.885-888
    • /
    • 2006
  • Nowaday, High strength concrete(HSC) has been mainly used in high rise building. HSC have superior property as well as improvement in durability compared with ordinary strength concrete. In spite of durability of HSC, explosive spalling in concrete front surface near the source of fire occurs serious problem in structural safety. Thus, this study is concerned with experimentally investigation fire resistance of the inorganic fire protection materials at high temperatures up to $800^{\circ}C$. From the test result, developed inorganic binder becomes general that with rising temperature the compressive strength of the material increases in tendency. Therefore, the results indicate that it is possible to fireproof panels, fire protection of materials, etc.

  • PDF

프리캐스트 프리스트레스트 내화단면 중공슬래브의 부재두께에 따른 화재거동평가 (A Evaluation of Fire Behavior According to Member Thickness of Precast Prestressed Hollow Core Slab of Fire Resistance Section )

  • 부윤섭;배규웅;신상민
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제27권1호
    • /
    • pp.1-8
    • /
    • 2023
  • 최근 건설현장은 인건비 상승, 중대재해처벌법 등으로 인한 건설 현장 여건의 변화로 탈현장 여건으로 프리캐스트 부재 생산에 대한 관심이 증대되고 있다. 특히, 프리캐스트 프리스트레스트 중공슬래브는 단면 내 중공형상을 두어, 중량감소 및 강연선을 통한 처짐 제어 등으로 구조성능은 확보하고 있으나, 현재 내화 성능 개선에 대한 미비한 연구 뿐만 아니라, 기업들의 근거 없는 당연내화구조 기준을 적용함에 내화성능 확보에 대한 시급성이 대두되고 있다. 이 연구에서는 기존 중공 슬래브와 비교하여 동등이상 구조성능, 경제성을 갖기 위하여 슬래브단면 내 중공 형상 최적화를 통해 단면 내 콘크리트 충진률 감소 및 상하부 플랜지 형상 개선으로 내화단면을 개발하였다. 이를 적용한 PC 중공 슬래브에 대하여 단면두께를 변수로 하여 2시간 내화시험을 진행하여, 실험결과 내화 성능(하중지지력, 차열성, 차염성)을 확보 하였다. 실험 결과 기반으로, 수치해석 시뮬레이션을 통해 내화모델링을 정립하여, 추후 단면형상 변경에 따라 내화 해석 예측이 가능한 것으로 판단된다.

고성능 RC 기둥의 마감재 변화에 따른 폭열 및 내화특성에 관한 연구 (A Study on the Properties of Fire Endurance and Spalling of High Performance RC Column with the Finishing and Covering Material)

  • 한천구;황인성;지석원;김경민
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제10권2호
    • /
    • pp.143-152
    • /
    • 2006
  • 건축물의 초고층화에 따라 최근 고성능 콘크리트의 사용이 증가하고 있다. 이러한 고성능 콘크리트는 고강도, 고유동, 고내구성 등 다양한 성능을 발휘하지만, 화재시 폭열에는 약한 것으로 알려져 있다. 본 연구는 PP섬유 혼입 및 마감재 변화에 따른 고성능 RC 기둥의 폭열방지 성능을 검토한 것이다. 실험결과 내화시험 후 폭열특성으로, 먼저 플레인의 경우 심한 파괴 폭열과 함께 철근이 노출됐고 내화뿜칠로 마감한 고성능 콘크리트는 내부 수분의 영향으로 플레인보다 더욱 심한 폭열을 나타냈다. 또한, 마감재 변화에 따른 시험체의 폭열특성으로는 내화도료로 마감한 경우가 가장 우수한 폭열방지 효과를 나타냈으며 폴리프로필렌 섬유를 0.1%혼입한 콘크리트는 3시간 가력 내화시험 후 가장 안전한 폭열방지 성능을 입증하였다.

음향방출법에 의한 고강도 구조용 내화강의 열화특성에 관한 연구 (A Study on Degradation Characteristic of High Strength Fire Resistance Steel for Frame Structure by Acoustic Emission)

  • 김현수;강창룡;남기우;김부안
    • 열처리공학회지
    • /
    • 제13권5호
    • /
    • pp.309-317
    • /
    • 2000
  • Demand for new nondestructive evaluations is growing to detect tensile crack growth behavior to predict long term performance of materials and structure in aggressive environments, especially when they are in non-visible area. Acoustic emission technique is well suited to these problems and has drawn a keen interests because of its dynamic detection ability, extreme sensitivity and location of growing defects. In this study, we investigated the strength of fire resistance steel for frame structure by tensile test after degradation treatment and analysed acoustic emission signals obtained from tensile test with time frequency analysis methods. In the T and TN specimens(under $600^{\circ}C$-10min ) consisting of ferrite and pearlite structure, most of acoustic emission events were produced near yield point, mainly due to the dislocation activities during the deformation. However, B specimen under $600^{\circ}C$-10min had a two peak which was attribute to the presence of martensite phase. The first peak is before yield point and the second after yield point. The sources of second acoustic emission peak were the debonding of martensite-martensite interface and the micro-cracking of brittle martensite phase. In $600^{\circ}C$-30min to $700^{\circ}C$-60min, many signals were observed before yield point and were decreased after yield point.

  • PDF

옥내용 뿜칠내화피복재의 촉진내구성 시험방법 연구 (Development of Acceleration Duability Test Method for Fireproof Spray-Applocation)

  • 김대회;이건철;이세현
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 추계 학술논문 발표대회
    • /
    • pp.104-105
    • /
    • 2013
  • The buildings constructed with steel structure is coated with certified fire resistive material to resist from fire. Coating materials lose their initial performances as time passes, so they need some maintenance. Fireproof spray-application also loses its performance and this performance loss of thr fireproof spray-application is very important because fire resistance of buildings depends on fireproof spray-application. So this study is to develop Acceleration durability test method of Fireproof spray-application, and use the Certification of fire resistant coating system.

  • PDF

A60급 구획 적용 격벽 관통용 관의 열전달 특성 II: 관 재질 및 단열재 종류에 따른 방화시험 (Heat Transfer Characteristics of Bulkhead Penetration Piece for A60 Class Compartment II: Fire Resistance Test for Piece Material and Insulation Types)

  • 박우창;송창용
    • 한국해양공학회지
    • /
    • 제33권4호
    • /
    • pp.340-349
    • /
    • 2019
  • In the case of a fire accident on a ship or an offshore plant, the design of the bulkhead penetration piece must be verified via a fire test procedure (FTP), as specified by the Maritime Safety Committee (MSC). The purpose of this study is to verify both the numerical analysis results and the design specifications for penetration pieces that could be applied to the A60 class bulkhead division. In this study, the FTP was carried out in accordance with the test procedure prescribed in the MSC regulation. In order to review the fire resistance performance according to the material type, bulkhead penetration pieces for the FTP were made from brass, carbon steel for machine structures (S45C), and austenite stainless steel (SUS316). In addition, spray-type insulation and mechanical fastener-type insulation were applied to investigate the fire resistance performance according to the type of insulation. To verify the heat transfer numerical analysis results for the A60 class bulkhead penetrating piece from this test study, the design specifications of the penetrating piece material and the insulation type applicable to a ship and an offshore plant were identified.

무기발포체의 화재확산 방지용 외장재 적용을 위한 물성평가 (Physical Properties of Inorganic Foam Material for Exterior Fire Resistance Material)

  • 신현욱;김지현;송훈;추용식;이종규
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 춘계 학술논문 발표대회
    • /
    • pp.124-125
    • /
    • 2016
  • This study is to development of inorganic insulation material using by-product materials. The organic material is due to toxic gas emission, when a fire occurs. And it has lower water resistance. The inorganic material is heavy and worse thermal performance than organic materials.In this study, cullet and fly ash were used as basic materials in order to secure a recycling technology of by-products which was mostly discarded and reclimed, and measure of physical properties of light-weight ceramic insulator.

  • PDF

전기콘센트의 사용환경과 전류값에 따른 열적특성 및 절연저항 분석 (Analysis of Thermal Characteristics and Insulation Resistance based on Usage Environment and Current Value of Electrical Socket Outlet)

  • 김경천;김두현;김성철
    • 한국안전학회지
    • /
    • 제34권5호
    • /
    • pp.22-30
    • /
    • 2019
  • In 2018, overload, overcurrent, insulation aging, and a contact failure caused 659 electric fires. There is almost no failure of electrical socket outlets during their manufacturing or installation period. After several months or several years, overload or overcurrent of electrical socket outlets leads to a contact failure or short circuit which causes an electric fire. Therefore, this paper analyzed for thermal characteristics based on a current value and the change in insulation resistance along with a temperature rise caused by electrical socket outlets and the state of laboratory use in workplaces. As a results, regarding the thermal characteristics based on the current value of each installation year, a temperature increase was related to a current value, an installation year, and whether the contact unit is corroded. Insulation resistance began to decrease when a temperature increased to a certain level. With a lapse of installation year, the temperature at which insulation resistance began to decrease was lowered. This paper can be applicable for the survey data about electrical socket outlet induced fire accidents and management guidelines.