Browse > Article
http://dx.doi.org/10.4334/IJCSM.2008.2.2.071

Effect of Fire Induced Spalling on the Response of Reinforced Concrete Beams  

Kodur, V.K.R. (Dept., Michigan State University)
Dwaikat, M.B. (Dept., Michigan State University)
Publication Information
International Journal of Concrete Structures and Materials / v.2, no.2, 2008 , pp. 71-81 More about this Journal
Abstract
A macroscopic finite element model is applied to investigate the effect of fire induced spalling on the response of reinforced concrete (RC) beams. Spalling is accounted for in the model through pore pressure calculations in concrete. The principles of mechanics and thermodynamics are applied to compute the temperature induced pore pressure in the concrete structures as a function of fire exposure time. The computed pore pressure is checked against the temperature dependent tensile strength of concrete to determine the extent of spalling. Using the model, case studies are conducted to investigate the influence of concrete permeability, fire scenario and axial restraint on the fire induced spalling and also on the response of RC beams. Results from the analysis indicate that the fire induced spalling, fire scenario, and axial restraint have significant influence on the fire response of RC beams. It is also shown that concrete permeability has substantial effect on the fire induced spalling and thus on the fire response of concrete beams. The fire resistance of high strength concrete beams can be lower that that of normal strength concrete beams due to fire induced spalling resulting from low permeability in high strength concrete.
Keywords
fire induced spalling; pore pressure; numerical model; fire resistance; concrete beams;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Kodur, V. R. and Dwaikat, M. B., "Performance-Based Fire Safety Design of Reinforced Concrete Beams," Journal of Fire Protection Engineering, Vol. 17, No. 4, 2007, pp. 293-320   DOI
2 ASCE 7-05, "Minimum Design Loads for Buildings and Other Structures," American Society of Civil Engineers, Reston, VA, 2005
3 Lie, T. T. (Editor), "Structural Fire Protection," ASCE Manuals and Reports of Engineering Practice, No 78, American Society of Civil Engineers, New York, 1992
4 Bazant, Z. P., and Thonguthai, W., "Pore pressure and Drying of Concrete at High Temperature," Journal of the Engineering Mechanics Division, ASCE, Vol. 104, No. EM5, 1978, pp. 1059-1079
5 Phan, L. T., "Fire Performance of High-Strength Concrete," A Report of the State-of-the-Art. National Institute of Standards and Technology, Gaithersburg, MD, 1996, 105 pp
6 Diederichs, U., Jumppanen, U. M., and Schneider, U., "High Temperature Properties and Spalling Behaviour of HSC," Proceedings of 4th Weimar Workshop on HPC, HAB Weimar, Germany, 1995, pp. 219-235
7 Kodur, V. R. and Sultan, M. A., "Structural Behaviour of High Strength Concrete Columns Exposed to Fire," Proceedings: International Symposium on High Performance and Reactive Powder Concrete, Sherbrooke, Quebec, Vol. 4, 1998, pp. 217-232
8 Danielsen, Ulf., "Marine Concrete Structures Exposed to Hydrocarbon Fires," Report, SINTEF - The Norwegian Fire Research Institute, 1997, pp. 56-76
9 Anderberg, Y. and Thelandersson, S., "Stress and Deformation Characteristics of Concrete at High Temperatures, 2. Experimental Investigation and Material Behaviour Model," Lund Institute of Technology, Sweden, 1976
10 ASTM Test Method E1529, "Standard Test Methods for Determining Effects of Large Hydrocarbon Pool Fires on Structural Members and Assemblies," American Society for Testing and Materials, West Conshohocken, PA, 1993
11 Baroghel-Bouny, V., Mainguy, M., Lassabatere, T., and Coussy, O., "Chatacterization and Identification of Equilibrium and Transfer Moisture Properties for Ordinary and High-Performance Cementations Materials," Cement Concrete Research, Vol. 29, 1999, pp. 1225-1238   DOI   ScienceOn
12 ASTM Test Method E119-08a, "Standard Methods of Fire Test of Building Construction and Materials," American Society for Testing and Materials, West Conshohocken, PA, 2008
13 Kalifa, P., Chene, G., and Galle, C., "High-Temperature Behavior of HPC with Polypropylene Fibers: From Spalling to Microstructure," Cement and Concrete Research, Vol. 31, 2001, pp. 1487-1499   DOI   ScienceOn
14 Bazant, Z.P. and Thonguthai, W., "Pore Pressure in Heated Concrete Walls: Theoretical Prediction," Magazine of Concrete Research, Vol. 31, No. 107, 1979, pp. 67-76   DOI   ScienceOn
15 ACI 318-2008, "Building Code Requirements for Reinforced Concrete," ACI 318-02 and Commentary, American Concrete Institute, Detroit, MI, 2008
16 Hertz, K. D., "Limits of Spalling of Fire-Exposed Concrete," Fire Safety Journal, Vol. 38, 2003, pp. 103-116   DOI   ScienceOn
17 Harmathy, T. Z., "Fire Safety Design and Concrete," Concrete Design and Construction Series, Longman Scientific and Technical, UK, 1993
18 Bazant, Z. P., Chern, J. C., and Thonguthai, W., "Finite Element Program for Mositure and Heat Transfer in Heated Concrete," Nuclear Engineering and Design, Vol. 68, 1981, pp. 61-70
19 Kodur, V. K. R., Wang, T., and Cheng, F., "Predicting the Fire Resistance Behavior of High Strength Concrete Columns," Cement & Concrete Composites, Elsevier Ltd., Vol. 26, No. 2, 2004, pp. 141-153   DOI   ScienceOn
20 Gawin, D., Majorana, C. E., and Schrefler, B. A., "Numerical Analysis of Hygro-thermic Behaviour and Damage of Concrete at High Temperature," Magazine of Cohesive Frictional Material, Vol. 4, 1999, pp. 37-74   DOI   ScienceOn
21 Eurocode 1, "ENV 1991-2-2: Basis of Design and Design Actions on Structures," Part 2-2: Actions on Structures Exposed to Fire, European Committee for Standardization, 1994
22 Feasey, R. and Buchanan, A. H., "Post Flash-over Fires for Structural Design," Fire Safety Journal, Vol 37, No 1, 2002, pp. 83-105   DOI   ScienceOn
23 Dwaikat, M. B. and Kodur, V. K. R., "A Numerical Approach for Modeling the Fire Induced Restraint Effects in Reinforced Concrete Beams," Fire Safety Journal, Vol. 43, No. 4, 2008, pp. 291-307   DOI   ScienceOn
24 Harmathy, T. Z., "A comprehensive Creep Model," Journal of Basic Engineering, Vol. 89, No. 2,1967, pp. 496-502   DOI
25 Kodur, V. R., "Guidelines for Fire Resistance Design of High Strength Concrete Columns," Journal of Fire Protection Engineering, Vol. 15, No. 2, 2005, pp. 93-106   DOI
26 Kodur, V. K. R., "Spalling in High Strength Concrete Exposed to Fire-Concerns, Causes, Critical Parameters and Cures," ASCE Structures Congress Proceedings, Philadelphia, U.S.A., 2000, pp. 1-8
27 Bilodeau, A., Kodur, V. R., and Hoff, G. C., "Optimization of the Type and Amount of Polypropylene Fibres for Preventing the Spalling of Lightweight Concrete Subjected to Hydrocarbon Fire," Cement and Concrete Composites Journal, Vol. 26, No. 2, 2004, pp. 163-175   DOI   ScienceOn
28 Fire Prevention, "Channel Tunnel Fire Protection Measures Questioned after Fire on HGV Wagon, Fire Prevention, 296, 1997
29 Kodur, V. K. R. and Phan, L., "Critical Factors Governing the Fire Performance of High Strength Concrete Systems," Fire Safety Journal, Vol. 42, 2007, pp. 482-488   DOI   ScienceOn
30 Dwaikat, M. B. and Kodur, V. K., "Hydrothermal Model for Predicting Fire Induced Spalling in Concrete Structural Systems", Fire Safety Journal, in Press, 2008
31 Eurocode 2, "prEN1992-1-2: Design of Concrete Structures," Part 1-2: General Rules - Structural Fire Design, Comite Europeen de Normalisation (CEN), Brussels, 2004
32 Neves, I. C., Rodrigues, J. C., and Loureiro, A. P., "Mechanical Properties of Reinforcing and Prestressing Steels after Heating," Journal of Materials in Civil Engineering, Vol. 8, No. 4, 1996, pp. 189-194   DOI   ScienceOn
33 ACI Committee 216.1, "Standard Method for Determining Fire Resistance of Concrete and Masonry Construction Assemblies," American Concrete Institute, Detroit; 2007