• 제목/요약/키워드: Material Removal

검색결과 1,690건 처리시간 0.039초

촉매 담지 코디어라이트 다공성 필터의 NOx/SOx 동시제거에 대한 연구 (Simultaneous Removal of NOx/SOx by Catalyst-loaded Cordierite Porous Filter)

  • 이시희;정구춘;김지웅;신민철;이희수
    • 분석과학
    • /
    • 제15권3호
    • /
    • pp.256-262
    • /
    • 2002
  • 평균입자크기가 200 ${\mu}m$인 코디어라이트 분말을 사용하여 다공성 필터를 제조한 후, 진공함침법으로 $V_2O_5$, CuO, $LaCoO_3$ 촉매를 담지시킨 후 NO와 $SO_2$ 기체를 촉매 담지 세라믹필터에 동시 통과시키면서 NOx/SOx의 동시제거효율을 측정하였다. 제조된 다공성 필터의 기공률은 61.6%였고, 압축강도는 12.3 MPa이었으며, 면속도 5 cm/sec에서의 차압은 147 Pa이었다. NO와 $SO_2$의 동시제거효율을 분석해 본 결과, 페로브스카이트계 $LaCoO_3$ 촉매의 동시제거효율이 가장 우수함을 확인하였으며, $LaCoO_3$ 촉매의 NO에 대한 제거효율은 90% 이상, $SO_2$에 대해서는 80% 이상이었다.

Effectiveness and safety of rotary and reciprocating kinematics for retreatment of curved root canals: a systematic review of in vitro studies

  • Lucas Pinho Simoes;Alexandre Henrique dos Reis-Prado;Carlos Roberto Emerenciano Bueno;Ana Cecília Diniz Viana ;Marco Antonio Hungaro Duarte ;Luciano Tavares Angelo Cintra;Cleidiel Aparecido Araujo Lemos;Francine Benetti
    • Restorative Dentistry and Endodontics
    • /
    • 제47권2호
    • /
    • pp.22.1-22.18
    • /
    • 2022
  • Objectives: This systematic review (register-osf.io/wg7ba) compared the efficacy and safety of rotary and reciprocating kinematics in the removal of filling material from curved root canals. Materials and Methods: Only in vitro studies evaluating both kinematics during retreatment were included. A systematic search (PubMed/MEDLINE, Scopus, and other databases, until January 2021), data extraction, and risk of bias analysis (Joanna Briggs Institute checklist) were performed. Efficacy in filling removal was the primary outcome. Results: The search resulted in 2,795 studies, of which 15 were included. Efficacy was measured in terms of the remaining filling material and the time required for this. Nine studies evaluated filling material removal, of which 7 found no significant differences between rotary and reciprocating kinematics. Regarding the time for filling removal, 5 studies showed no difference between both kinematics, 2 studies showed faster results with rotary systems, and other 2 showed the opposite. No significant differences were found in apical transportation, centering ability, instrument failure, dentin removed and extruded debris. A low risk of bias was observed. Conclusions: This review suggests that the choice of rotary or reciprocating kinematics does not influence the efficacy of filling removal from curved root canals. Further studies are needed to compare the kinematics safety in curved root canals.

전기전도성 이방성 복합재료 방전가공의 수치 해석 (Numerical Analysis of the Electro-discharge Machining Process of a Conductive Anisotropic Composite)

  • 안영철;천갑제
    • Korean Chemical Engineering Research
    • /
    • 제47권1호
    • /
    • pp.72-78
    • /
    • 2009
  • 전기전도성 이방성 복합재료의 방전가공에 대하여 비정상상태 수식모델을 세우고 갤러킨의 유한요소법으로 해를 구하였다. 피삭재의 온도 분포와 분화구의 모양 및 공작물 제거 속도를 공정 매개변수에 관하여 구득하였다. 계산의 정확도와 효율을 위하여 앞선 연구에서 최적치로 선정된 $12{\times}12$ 요소의 비규칙 체눈을 사용하였다. 알루미나/티타늄 카바이드 복합재료의 물성을 재료의 물성으로 선정하였고 51.4 V의 전압과 7 A의 전류를 갖는 전력을 적용하였으며 제거 효율을 10%로 전열 이방성 계수를 2와 3으로 가정하였다. 불꽃이 일어나면서 피삭재는 즉시 녹기 시작하였고 열적 손상 영역이 형성되었다. 또한 시간이 흘러감에 따라서 분화구의 경계가 이동하는 것이 확인되었다. 반경 방향과 축 방향의 열전도도가 독립적으로 커지면 온도분포와 분화구의 모양이 각각 반경 방향과 축 방향으로 이동하였다. 공작물 제거 속도는 축 방향의 열전도도보다 반경 방향의 열전도도가 증가할 때 더욱 커지는 것으로 나타났다.

Experimental design approach for ultra-fast nickel removal by novel bio-nanocomposite material

  • Ince, Olcay K.;Aydogdu, Burcu;Alp, Hevidar;Ince, Muharrem
    • Advances in nano research
    • /
    • 제10권1호
    • /
    • pp.77-90
    • /
    • 2021
  • In the present study, novel chitosan coated magnetic magnetite (Fe3O4) nanoparticles were successfully biosynthesized from mushroom, Agaricus campestris, extract. The obtained bio-nanocomposite material was used to investigate ultra-fast and highly efficient for removal of Ni2+ ions in a fixed-bed column. Chitosan was treated as polyelectrolyte complex with Fe3O4 nanoparticles and a Fungal Bio-Nanocomposite Material (FBNM) was derived. The FBNM was characterized by using X-Ray Diffractometer (XRD), Scanning Electron Microscopy-Energy Dispersive X-Ray Spectroscopy (SEM-EDS), Fourier Transform Infrared spectra (FTIR) and Thermogravimetric Analysis (TGA) techniques and under varied experimental conditions. The influence of some important operating conditions including pH, flow rate and initial Ni2+ concentration on the uptake of Ni2+ solution was also optimized using a synthetic water sample. A Central Composite Design (CCD) combined with Response Surface Modeling (RSM) was carried out to maximize Ni2+ removal using FBNM for adsorption process. A regression model was derived using CCD to predict the responses and analysis of variance (ANOVA) and lack of fit test was used to check model adequacy. It was observed that the quadratic model, which was controlled and proposed, was originated from experimental design data. The FBNM maximum adsorption capacity was determined as 59.8 mg g-1. Finally, developed method was applied to soft drinks to determine Ni2+ levels. Reusability of FBNM was tested, and the adsorption and desorption capacities were not affected after eight cycles. The paper suggests that the FBNM is a promising recyclable nanoadsorbent for the removal of Ni2+ from various soft drinks.

Fire Behavior of Steel Columns Encased by Damaged Spray-applied Fire Resistive Material

  • Kwak, Yoon Keun;Pessiki, Stephen;Kwon, Kihyon
    • Architectural research
    • /
    • 제10권1호
    • /
    • pp.1-11
    • /
    • 2008
  • A Steel column with damaged spray-applied fire resistive material (SFRM) may exhibit reduced structural performance due to the effects of elevated temperature during fire events. Thus, the fire load behavior of steel columns with removed or reduced SFRM needs to be examined to predict the structural damage by fire. FEM analyses were performed for the flange thinning removal models in which the SFRM was reduced as a constant strip in thickness at the top flange of the column. The temperature results for all models obtained from the heat transfer analyses were included as an initial condition in the FEM structural analyses. In this study, the results of analysis show that even small remnants of SFRM led to an effective reduction of temperature at any given fire duration, and improved significantly the axial load capacity of a column as compared to the complete removal cases of SFRM.

원통형과 packed-bed형 반응기에서 NOx제거특성 (NOx removal in cylinder type reactor and Packed-bed type reactor)

  • 박재윤;박상현;이경호;하상태;송원섭;황보국
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.499-502
    • /
    • 2001
  • In this experiment, an attempt to use the sludge pellets as catalyst for NO removal from simulated gas is experimentally investigated by using cylinder type reactor and packed-bed reactor. An experimental investigation has been conducted for NO concentration of 50[ppm], 100[ppm], 200[ppm] balanced with air, a gas flow rate of 5[1/min]. Ac voltage to discharge the gases was supplied. In the result, NOx removal rate in packed bed reactor is higher than that in cylinder type reactor. it is thought that plasma density in contact point of BaTiO$_3$ is significantly higher than that in cylinder reactor.

  • PDF

알칼라인 오존수를 아용한 입자제거에 관한 연구 (The Study of Particle Removal Efficiency (PRE) with Alkaline Ozonized Water)

  • 이승호;김태곤;이재환;박진구;배소익;이건호;김인정
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 추계학술대회 논문집 Vol.19
    • /
    • pp.362-363
    • /
    • 2006
  • Ozonized DI water was supplied to make alkaline cleaning solutions to replace SCI chemicals in a bath with and without recirculation. With recirculation, low dissolved ozone and low pH cause lower particle removal efficiency (PRE) of 75%. However, direct supply of ozonized water with $NH_4OH$ to a bath without recirculation resulted in higher PRE over 93 %.

  • PDF

실리카 슬러리의 재활용 특성 (Recycling Characteristics of Silica Abrasive Slurry)

  • 박성우;김철복;이우선;장의구;서용진
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 추계학술대회 논문집 Vol.17
    • /
    • pp.723-726
    • /
    • 2004
  • In this work, we have studied the CMP characteristics by mixing of original slurry and used slurry in order to investigated the possibility of recycle of used silica slurry. The removal rate and within-wafer non-uniformity (WIWNU) were measured as a function of different slurry composition. Also, we compared the CMP characteristics between self-developed KOH-based silica abrasive slurry and the original slurry. Our experimental results revealed comparable removal rate and good planarity with commercial products.

  • PDF

대기오염 가스 제거효율 향상을 위한 저온 플라즈마 응용기구 연구 (Non Thermal Plasma Applicable Mechanisms for the Improvement of Air Pollutants Removal Efficiency)

  • 김대일;김형택
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 추계학술대회 논문집 Vol.17
    • /
    • pp.648-652
    • /
    • 2004
  • A comparative investigation of an experimental and a simulation of chemical kinetics for NOx removal from dielectric barrier discharges is presented. Several types of dielectric barrier discharges were implemented depending upon the configuration of electrodes. The simulation was based on an approximate mathematical model for plasma cleaning of waste gas. The influence of non uniform distributions of species due to the production of primary active particles in the streamer channel was taken into account. A comparison of observed experimental to the calculated removal efficiency of NOx showed acceptable agreement.

  • PDF

DOE 방법을 이용한 Cu CMP 공정 변수의 최적화 (Optimization of Cu CMP Process Parameter using DOE Method)

  • 최민호;김남훈;김상용;장의구
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 추계학술대회 논문집 Vol.17
    • /
    • pp.711-714
    • /
    • 2004
  • Chemical mechanical polishing (CMP) has been widely accepted for the global planarization of multi-layer structures in semiconductor manufacturing. However, it still has various problems to the CMP equipment, in particular, among the CMP components, process variables are very important parameters in determining the removal rate and non-uniformity. Using a design of experiment (DOE) approach, this study was performed investigating the interaction between the various parameters such as turntable and head speed, down force and back pressure during CMP. Using statistical analysis techniques, a better understanding of the interaction behavior between the various parameters and the effect on removal rate, no-uniformity and ETC (edge to center) is achieved.

  • PDF