• Title/Summary/Keyword: Mass measurement type

Search Result 156, Processing Time 0.024 seconds

Development of Calibration System of Helium Permeation Type Standard Leaks (헬륨 투과형 표준리크 교정장치 개발)

  • Hong S.S.;Lim I.T.;Shin Y.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.4
    • /
    • pp.347-353
    • /
    • 2006
  • A helium permeation type standard leak calibration system has newly developed by using dynamic gas expansion method. The measurement range was extended lower to $10^{-6}$ Pa L/s for participating CCM (Consultative Committee for Mass and Related Quantities) standard leak key comparison. For the system, pressure ratios of high and ultra-high vacuum chamber and porous plug conductance for helium gas were determined. By using the system, a permeation type standard leak of $5.6{\times}10^{-4}$ Pa L/s range was calibrated. The calibration result showed that the difference between standard commercial leak was 11.1 %.

An Experimental Study on the Mixing Flow Structure of Turbulent Cross Flow with Respect to the Ratio of Mass Flow Rate (난류충돌유동의 질량유량비에 따른 혼합유동구조에 관한 실험적 연구)

  • 이대옥;노병준
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.11
    • /
    • pp.2150-2158
    • /
    • 1992
  • This study was carried out to investigate the flow structure and mixing process of a cross mixing flow formed by two round jets with respect to the ratio of mass flow rate. This flow configuration is of great practical relevance in a variety of combustion systems, and the flow behaviour of a cross jet defends critically on the ratio of mass flow rate and the cross angle. The mass flow rate ratios of two different jets were controlled as 1.0, 0.8, 0.6, and 0.4, and the crossing angle of two round jets was fixed at 45 degree. The velocities issuing from jet nozzle with an exit diameter of 20mm were adjusted to 40m/s, 32m/s, 24m/s, and 16m/s, and the measurements have been conducted in the streamwise range of $1.1X_0$to $2.5X_0$ by an on-line measurement system consisted of a constant temperature type two channel hot-wire anemometry connected to a computer analyzing system. The original air flow was generated by a subsonic wind tunnel with reliable stabilities and uniform flows in the test section. For the analysis of the cross mixing flow structure in the downstream region after the cross point, the mean velocity profiles, the resultant velocity contours, and the three-dimensional profiles depending upon the mass flow rate ratio have been concentrately studied.

Development of the PDA Based Mobile System for Body Fat Measurement and Diagnosis Using Bioelectrical Impedance Method (체임피던스 방법을 이용한 PDA 기반의 휴대용 체지방 측정 및 진단 시스템 개발)

  • 권세윤;이상민;김재환;우지환;김인영;이형기;방석원;김선일
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.1
    • /
    • pp.21-26
    • /
    • 2004
  • Recently, many people want to know their state of health, such as a body fat rate, anywhere and anytime. The Personal Digital Assistance(PDA) is the portable wireless apparatus that has become widely popular. There are many application areas of the IDA to be in mobile care devices. In this study, we developed the PDA based body fat measurement system, composed of a cradle type measurement module and a WindowCE operated software module, a regression equation for predicting lean body mass (LBM). Sixty-three weight-stable subjects (53 men, 10 women) aged 20∼32yr participated in this study. A regression model, LBM = (0.0005*Height2 - 0.0160*Impedance + 0.3920*Weight - 0.0684*Age - 5.8141*Sex + 25.984, was found. The correlation coefficient( r) of body fat rate between developed system and HTM1000plus(BionetTM) was 0.928. HTM1000plus is a commercially available and approved by KFDA. These results indicated that developed system is reliable for estimation of body fat rate. Although developed system is the PDA based miniaturized, it shows good performance comparing with other commercial product.

Effective Measuring Method of Discontinuity Orientation (불연속면 방향의 효율적인 측정 방안)

  • 김해경;고영구
    • The Journal of Engineering Geology
    • /
    • v.13 no.3
    • /
    • pp.321-334
    • /
    • 2003
  • This study is aimed at the effective measurement plan of discontinuity orientation on rock mass. The discontinuity orientation is expressed as three methods. strike/dip. dipdirection/dip (a three digit number / a two digit number) and right hand rule. Generally, strike/dip is measured with clinometer. and dipdirection/dip with silva compass(type15). A sign of strike/dip. discontinuity orientation is used to geological survey. and dipdirection/dip to engineering. Dipdirection/dip converted by strike/dip measured with clinometer is useful on the statistical analysis of a lot of data. To measure the azimuth of the dip with clinometer and to change strike/dip to dipdirection/dip may have potential errors in each person. The newly designed apparatus, clinometer equipped by a rotational azimuth plate and an arrow to measuring strike and dipdirection, has been developed to measure effectively the discontinuity orientation with two method (strike/dip and dipdirection/dip). The measuring method of discontinuity orientation with clinometer having newly designed apparatus is effective one for accurate measurement of strike as well as dipdirection which is degrees counted clockwise from true north. Used by clinometer with newly designed apparatus, concurrent measuring strike/dip and dipdirecton/dip of discontinuity is possible. In application to measuring discontinuity orientation on rock slope, it has been recognized that the newly designed method, unambiguously, led to drop measuring errors comparing with existing measuring apparatuses. Therefore, it is considered that measuring method of discontinuity orientation (strike/dip and dipdirecton/dip) by the newly designed apparatus is useful to one in geological engineering investigation of road design, and to unskilled investigator.

Growth of GaAs/AlGaAs structure for photoelectric cathode (광전음극 소자용 GaAs/AlGaAs 구조의 LPE 성장)

  • Bae, Sung Geun;Jeon, Injun;Kim, Kyoung Hwa
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.27 no.6
    • /
    • pp.282-288
    • /
    • 2017
  • In this paper, GaAs/AlGaAs multi-layer structure was grown by liquid phase epitaxy with graphite sliding boat, which can be used as a device structure of a photocathode image sensor. The multi-layer structure was grown on an n-type GaAs substrate in the sequence as follows: GaAs buffer layer, Zn-doped p-type AlGaAs layer as etching stop layer, Zn-doped p-type GaAs layer, and Zn-doped p-type AlGaAs layer. The Characteristics of GaAs/AlGaAs structures were analyzed by using scanning electron microscope (SEM), secondary ion mass spectrometer (SIMS) and hall measurement. The SEM images shows that the p-AlGaAs/p-GaAs/p-AlGaAs multi-layer structure was grown with a mirror-like surface on a whole ($1.25mm{\times}25mm$) substrate. The Al composition in the AlGaAs layer was approximately 80 %. Also, it was confirmed that the free carrier concentration in the p-GaAs layer can be adjusted to the range of $8{\times}10^{18}/cm^2$ by hall measurement. In the result, it is expected that the p-AlGaAs/p-GaAs/p-AlGaAs multi-layer structure grown by the LPE can be used as a device structure of a photoelectric cathode image sensor.

A Study on the Emission of VOCs in Parking Lot Floor Coating (주차장 바닥 코팅제의 휘발성유기화합물 배출에 관한 연구)

  • Lee, Seung-Chan;Yoon, Gil-Ho;Park, Yong-Soon;Kil, Bae-Su;Yoon, Hyun-Do
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.4
    • /
    • pp.152-158
    • /
    • 2019
  • Measure the type and content of VOCs for A-company epoxy coating and B-company floor coating(Type A, B), which are used as flooring materials for parking lots. Than the VOCs used gas detectors to measure gas emissions, assuming the worst environment to reduce errors in external environments in the formaldehyde, toluene and xylene harmful to workers and tenants. As a result, A-company epoxy coating has the largest amount of VOCs, and compared to A-company epoxy coating, B-company floor coating of A type represented about 79% less and B type about 96% less. In addition, A-company epoxy coating was also the highest in gas emission measurement for formaldehyde, toluene and xylene using gas detector after 1 hour and 8 hours in closed environment conditions. B-company floor coating A type was less than A-company epoxy coating, which was about 42.3% less measured. And type B satisfied all TWA even in closed environment conditions.

Comparison of Muscle Fiber and Meat Quality Characteristics in Different Japanese Quail Lines

  • Choi, Y.M.;Hwang, S.;Lee, K.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.29 no.9
    • /
    • pp.1331-1337
    • /
    • 2016
  • The aim of this study was to compare the growth performance, fiber characteristics of the pectoralis major muscle, and meat quality characteristics in the heavy weight (HW) and random bred control (RBC) quail lines and genders. The HW male exhibited more than two times greater body (245.7 vs 96.1 g, p<0.05) and pectoralis major muscle (PMW; 37.1 vs 11.1 g, p<0.05) weights compared to the RBC female. This growth performance in the HW line was associated with a greater muscle fiber area (1,502 vs $663.0{\mu}m^2$, p<0.001) compared to the RBC line. Greater muscle mass of the HW male was accompanied by a higher percentage of type IIB fiber compared to the HW female (64.0% vs 51.0%, p<0.05). However, muscle fiber hyperplasia (increase in fiber number) has had a somewhat limited effect on PMW between the two lines. On the other hand, the HW line harboring a higher proportion of type IIB fiber showed rapid pH decline at the early postmortem period (6.23 vs 6.41, p<0.05) and lighter meat surface (53.5 vs 47.3, p<0.05) compared to the RBC line harboring a lower proportion of type IIB fiber. There were no significant differences observed in the measurement of water-holding capacity including drip loss (2.74% vs 3.07%, p>0.05) and cooking loss (21.9% vs 20.4%, p>0.05) between the HW and RBC lines. Therefore, the HW quail line developed by selection from the RBC quail, was slightly different in the meat quality characteristics compared to the RBC line, and a marked difference was found in growth performance between the two quail lines.

Effects of CF4 Plasma Treatment on Characteristics of Enhancement Mode AlGaN/GaN High Electron Mobility Transistors

  • Horng, Ray-Hua;Yeh, Chih-Tung
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.62-62
    • /
    • 2015
  • In this study, we study the effects of CF4 plasma treatment on the characteristics of enhancement mode (E-mode) AlGaN/GaN high electron mobility transistors (HEMTs). The CF4 plasma is generated by inductively coupled plasma reactive ion etching (ICP-RIE) system. The CF4 gas is decomposed into fluorine ions by ICP-RIE and then fluorine ions will effect the AlGaN/GaN interface to inhibit the electron transport of two dimension electron gas (2DEG) and increase channel resistance. The CF4 plasma method neither like the recessed type which have to utilize Cl2/BCl3 to etch semiconductor layer nor ion implantation needed high power to implant ions into semiconductor. Both of techniques will cause semiconductor damage. In the experiment, the CF4 treatment time are 0, 50, 100, 150, 200 and 250 seconds. It was found that the devices treated 100 seconds showed best electric performance. In order to prove fluorine ions existing and CF4 plasma treatment not etch epitaxial layer, the secondary ion mass spectrometer confirmed fluorine ions truly existing in the sample which treatment time 100 seconds. Moreover, transmission electron microscopy showed that the sample treated time 100 seconds did not have etch phenomena. Atomic layer deposition is used to grow Al2O3 with thickness 10, 20, 30 and 40 nm. In electrical measurement, the device that deposited 20-nm-thickness Al2O3 showed excellent current ability, the forward saturation current of 210 mA/mm, transconductance (gm) of 44.1 mS/mm and threshold voltage of 2.28 V, ION/IOFF reach to 108. As IV concerning the breakdown voltage measurement, all kinds of samples can reach to 1450 V.

  • PDF

Utilizing the grazing effect of fresh water clams (Unio douglasiae) for the remediation of algal bloom during summer

  • Nam, Ki-Woong;Lee, Jeong-Ryul;Park, Kyung-Il
    • The Korean Journal of Malacology
    • /
    • v.31 no.1
    • /
    • pp.61-67
    • /
    • 2015
  • The occurrence of 'algal bloom', caused by the mass proliferation of phytoplankton, causes serious problems in streams and lakes in Korea. Therefore, in this study, the phytoplankton filter-feeding trait of Unio douglasiae, a type of freshwater clam, was used to reduce the algal bloom in outdoor water tanks during the summer. This involved the construction of a U. douglasiae cultivation apparatus, wherein 1,000 clams were divided into 8 rectangular baskets arranged in the shape of an empty square. The control tank was manufactured in exactly the same shape within the water tank, but without the addition of clams. The algal bloom-reducing effect of U. douglasiae was confirmed by the measurement of (and comparing between) the water quality at the center and periphery of the test and control cultivation apparatus. Water quality measurements included the measurement of water temperature, pH, turbidity, dissolved oxygen (DO) content, and chlorophyll-${\alpha}$ concentrations; the water quality was measured twice a month between June and November 2014.The results of these analyses did not show a significant difference in water quality (temperature, pH, turbidity, DO) between the center and periphery of the test and control tanks. However, the chlorophyll-${\alpha}$ concentration was observed to be much lower at the center of the test tank compared to that at the center and periphery of the control tank, as well as at the periphery of the test tank. This was believed to be a result of the U. douglasiae surrounding the center of the test tank, which prevented the influx of plankton from the periphery. Accordingly, the results of these analyses suggest the possibility that U. douglasiae cultivation could reduce the proliferation of algal blooms in lakes and streams during the summer. In particular, these results indicate possible improvements in U. douglasiae activity (reduction in algal blooms) by their effective arrangement in the water bodies.

In Vivo Measurement of Site-Specific Peritoneal Solute Transport Using a Fiber-Optic-based Fluorescence Photobleaching Technique

  • Lee, Donghee;Kim, Jeong Chul;Shin, Eunkyoung;Ju, Kyung Don;Oh, Kook-Hwan;Kim, Hee Chan;Kang, Eungtaek;Kim, Jung Kyung
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.3
    • /
    • pp.228-236
    • /
    • 2015
  • Fluorescence recovery after photobleaching (FRAP) is a well-established method commonly used to measure the diffusion of fluorescent solutes and biomolecules in living cells or tissues. Here a fiber-optic-based FRAP (f-FRAP) system was developed, and validated using macromolecules in water and agarose gels of different concentrations. We applied f-FRAP to measure the site-specific diffusion of fluorescein (NaFluo) in peritoneal membranes (PMs) on the liver, cecum, and kidney of a living rat during peritoneal dialysis. Diffusion of fluorescein in PM varied in a time-dependent manner according to the type of organ ($D_{PM\;on\;Liver}/D_{NaFluo}=0.199{\pm}0.085$, $D_{PM\;on\;Cecum}/D_{NaFluo}=0.292{\pm}0.151$, $D_{PM\;on\;Kidney}/D_{NaFluo}=0.218{\pm}0.110$). The proposed method allows direct quantitative measurement of the three-dimensional diffusion in local PM in vivo, which was previously inaccessible by peritoneal function test methods such as peritoneal equilibration test (PET) and standardized PM assessment (SPA). f-FRAP is promising for local and dynamic assessments of peritoneal pathophysiology and the mass transport properties of PMs, presumed to be affected by variation of tissue structures over different organs and functional changes of the PM with years of peritoneal dialysis.