Browse > Article

Development of the PDA Based Mobile System for Body Fat Measurement and Diagnosis Using Bioelectrical Impedance Method  

권세윤 (한양대학교 의공학교실)
이상민 (한양대학교 의공학교)
김재환 (한양대학교 의공학교)
우지환 (한양대학교 의공학교)
김인영 (한양대학교 의공학교)
이형기 (삼성전자(주) 삼성종합기술원 HCI)
방석원 (삼성전자(주) 삼성종합기술원 HCI)
김선일 (한양대학교 의공학교실)
Publication Information
Journal of Biomedical Engineering Research / v.25, no.1, 2004 , pp. 21-26 More about this Journal
Abstract
Recently, many people want to know their state of health, such as a body fat rate, anywhere and anytime. The Personal Digital Assistance(PDA) is the portable wireless apparatus that has become widely popular. There are many application areas of the IDA to be in mobile care devices. In this study, we developed the PDA based body fat measurement system, composed of a cradle type measurement module and a WindowCE operated software module, a regression equation for predicting lean body mass (LBM). Sixty-three weight-stable subjects (53 men, 10 women) aged 20∼32yr participated in this study. A regression model, LBM = (0.0005*Height2 - 0.0160*Impedance + 0.3920*Weight - 0.0684*Age - 5.8141*Sex + 25.984, was found. The correlation coefficient( r) of body fat rate between developed system and HTM1000plus(BionetTM) was 0.928. HTM1000plus is a commercially available and approved by KFDA. These results indicated that developed system is reliable for estimation of body fat rate. Although developed system is the PDA based miniaturized, it shows good performance comparing with other commercial product.
Keywords
Lean body mass; Bioelectrical impedance analysis(BIA); PDA;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Densitometric analysis of body composition /
[ J. Brozek.;F. Grande;J.T. Anderson.;A. Keys. ] / Ann NY Acad Sci.
2 Assessment of abdominal fat content by computer tomography /
[ G.A. Borkan;S,G, Gerzof;A.H. Robbins;D.E. Hults;C.K. Silbert;J.E. Silbert ] / America Journal of Clinical Nutrition
3 Correlation of whole-body impedance with total body water volume /
[ E.C. Hoffer;C. Meador;D.C. Simpson ] / Journal of Applied Physiology
4 Total body electrical conductivity: New developments and expanded applications /
[ R.C. Funk;B.F. Kerekes;R.C. Lanphier;J.G Kral(ed.);T.B. Van Itallie(ed.) ] / Recent developments in body compostition analysis: Methods and applications
5 The specific resistance of biological material: A compendium of data for the biomedical engineer and physiologist /
[ L.A. Geddes;L.E. Baker ] / Medical and Biological engineering and Computing   DOI
6 Percent body fat by four terminal bio-electrical impedance and body density in coledge freshmen /
[ J. Nyboer ] / In Priceedings of the Vth International Coference in Electrical Bio-impedance
7 Measurement of body fat by Impedance Technique /
[ D.W. Kim;C.G. Song;S.K. Hwang ] / Journal of KOSOMBE
8 Lean body mass estimated by bioelectrical impedance alanysis: A four site cross validation study /
[ K.R. Segal;M.N. Van Loan.;P.I. Fitzgerald(et al.) ] / American Journal of Clinical Nutrition
9 /
[ Roche, Alex F.(et al.) ] / Human body composition
10 Assessment fat mass using bioelectric impedance measurements of the human body /
[ H.C. Lukaski;P.E. Johson;W.W. Bolonchuk;G.I. Lykken ] / American Journal of Clinical Nutrition
11 Measurement of total body electrical conductivity for the setimation of fat and fat-free mass /
[ M.L. Fiorotto;Whitechead(ed.);A. Prentice(ed.) ] / New technique in nutritional research
12 Nutritinal assessment: Whole body impedance and body fluid compartments /
[ R.G. Settle;K.R. Foster;B.R. Epstein;J.L. Mullen ] / Nutriton and Cancer   DOI
13 Skinfolds and body density and their relation to body fatness : a review /
[ S.G. Lohman ] / Human Biol
14 Validity of the ultrasonic technique as a method of measuring subcutaneous adipose tissue /
[ E.M. Haymes;H.M. Lundgreen;J.L. Loomis;E.R. Buskrik ] / Ann Human Biol   DOI   ScienceOn