• 제목/요약/키워드: Mass Measurement

검색결과 1,501건 처리시간 0.031초

매스콘크리트의 수화열 해석 및 현장 계측을 통한 수화발열량차 공법의 현장적용성 (Field Application of Foundation Mass Concrete Applying Hydration Heat Differential Method and Insulation Curing Method)

  • 한준희;임군수;신세준;전충근;김종;한민철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.229-230
    • /
    • 2023
  • In this study, the hydration heat differential method was applied to mass concrete structures, and the hydration heat analysis was compared and analyzed with on-site measurement results. The results showed that the temperature history measurements of mass concrete were managed at a difference of 8.4 ℃, and although there was some deviation in thermal stress, a similar trend was observed. Consequently, it was determined that the thermal stress on the surface of mass concrete is less than its tensile strength, which would prevent the occurrence of thermal cracks.

  • PDF

First Example of Monometallic Palladium(II) Compound with Trans-Chelating Tridentate Ligand: Synthesis, Crystal Structure, and Characterizations

  • Tae Hwan Noh
    • Mass Spectrometry Letters
    • /
    • 제14권3호
    • /
    • pp.110-115
    • /
    • 2023
  • The reaction of (COD)PdCl2 with new C3-symmetric tridentate L (COD = 1,5-cyclooctadien; L = 1,3,5-tris(picolinoyloxyethyl)cyanurate) in a mixture of acetone and dichloromethane produces single crystals consisting of unprecedented monometallacyclic [PdCl2(L)]. This cyclic compound arises from trans-chelation of two of three donating pyridyl groups of L, while the third pyridyl group remains uncoordinated. Electrospray ionization mass spectrometry (ESI-MS) data on L exhibited the major peak corresponding to [C27H24N6O9 + H+]+. Fast atom bombardment mass spectrometry (FABMS) data on [PdCl2(L)], however, showed the mass peak corresponding to the L instead of the present palladium(II) compound species, due to the insolubility and dissociation in solution. The physicochemical properties of the present palladium(II) compound were fully characterized by means of infrared (IR) and nuclear magnetic resonance (NMR) spectroscopy, thermal analysis, single-crystal X-ray diffraction (SC-XRD) measurement.

Ultrafine Particle의 독성, 측정방법 및 관리 (Ultrafine Particle Toxicities, Current Measurement Techniques and Controls)

  • 이수길;김성수
    • 한국산업보건학회지
    • /
    • 제20권3호
    • /
    • pp.203-215
    • /
    • 2010
  • This study is an overview of toxicities and measurement techniques of ultrafine particles (UFPs), and their exposure controls. UFPs are ubiquitous in many working situations. Exposure to UFPs is possibly causing adverse health symptoms including cardio-respiratory disease to humans. In order to measure exposure levels of airborne UFPs, there are current available measurement guidelines, instruments and other techniques (i.e. contour mapping, control banding). However, these risk assessment techniques including measurement techniques, controls and guidelines are dependent on background levels, metrics (e.g. size, mass, number, surface area, composition), environmental conditions and controls. There are no standardized measurement methods available and no generic and specific occupational exposure standards for UFPs. It is thought that there needs to be more effort to develop Regulations and Exposure Standards for generic UFPs should be based on more exposure data, health surveys, toxicological data and epidemiological data. A carefully considered hierarchy of controls can also reduce the maximum amount of airborne UFPs being emitted from diverse sources in industries.

정밀가공 부품 검사에 사용되는 3차원측정기의 측정불확도 연구 (A Study on Measurement Uncertainty of 3-dimensional Coordinate Measuring Machine used for Inspection of Precision Machined parts)

  • 이갑조;오상록;김종관
    • 한국공작기계학회논문집
    • /
    • 제14권2호
    • /
    • pp.55-61
    • /
    • 2005
  • The machining Parts must be Produced within the specification of drawing and those will be able to meet faction and efficiency. At that time, it is very important not only precision machine and machining technique but also the measurement technique. So, the improvement of measurement technique is to be joined together at once with improvement of machining technique. Finally, the quality and value of the parts are decided by precision measurement. This paper aims to study on the measurement uncertainty when the machined parts are inspected with 3-dimensional coordinate measuring machine. The objectives remove an error of measurement and remove a quality of mass products.

Non-invasive Methods for Determination of Cellular Growth in Podophyllum hexandrum Suspension Cultures

  • Chattopadhyay, Saurabh;Bisaria, V.S.;Scheper, T.;Srivastava, A.K.
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제7권6호
    • /
    • pp.331-334
    • /
    • 2002
  • Culture conductivity and on-line NADH fluorescence were used to measure cellular growth in plant cell suspension cultures of Podophyllum hexandrum. An inverse correlation between dry cell weight and medium conductivity was observed during shake flask cultivation. A linear relationship between dry cell weight and culture NADH fluorescence was obtained during the exponential phase of batch cultivation In a bioreactor under the pH stat (pH 6) conditions. It was observed that conductivity measurement were suitable for biomass characterisation under highly dynamic uncontrolled shake flask cultivation conditions. However, if the acid/alkali feeding is done for pH control the conductivity measurement could not be applied. On the other hand the NADH fluorescence measurement allowed online-in situ biomass monitoring of rather heterogenous plant cell suspension cultures in bioreactor even under the most desirable pH stat conditions.

Statistical analysis of KNHANES data with measurement error models

  • Hwang, Jinseub
    • Journal of the Korean Data and Information Science Society
    • /
    • 제26권3호
    • /
    • pp.773-779
    • /
    • 2015
  • We study a statistical analysis about the fifth wave data of the Korea National Health and Nutrition Examination Survey based on linear regression models with measurement errors. The data is obtained from a national population-based complex survey. To demonstrate the availability of measurement error models, two results between the general linear regression model and measurement error model are compared based on the model selection criteria which are Akaike information criterion and Bayesian information criterion. For our study, we use the simulation extrapolation algorithm for measurement error model and the jackknife method for the estimation of standard errors.

In Vitro에서 히스타민 측정 시 ELISA법과 HPLC-MS 분석법의 비교 (Comparison of Methods for Measuring Histamine by ELISA and HPLC-MS Assay In Vitro)

  • 이인희;김유현
    • 대한임상검사과학회지
    • /
    • 제47권4호
    • /
    • pp.306-312
    • /
    • 2015
  • 알러지 반응이 일어나면 histamine이 방출되기 때문에 histamine을 정량 측정함으로써 유발된 알러지의 정도를 확인 할 수 있다. 일반적으로는 항원-항체반응으로 microplate reader를 이용하여 흡광도를 측정하여 정량 한다. 본 연구에서는 histamine 방출량을 측정함에 있어서 일반적인 항원-항체반응과 분석 화학적인 방법으로 HPLC-MS를 이용한 방법을 비교하였다. 세포주는 RBL-2H3를 사용하였고, C48/80으로 자극시켜 알러지를 유발하였다. 유발된 알러지는 ${\beta}$-hexosaminidase의 측정으로 탈 과립을 확인하였으며 실험의 정당성을 위하여 세포독성 능을 확인하였다. Histamine 정량에서 항원-항체반응에 의한 측정의 정량한계는 10.257 ppm이었고, HPLC-MS에 의한 정량한계는 0.020 ppm으로 현저한 차이를 보였다. 알러지 활성 및 항 알러지 실험에 있어서 histamine의 측정은 HPLC-MS를 이용한 분석이 더 정밀하고 정확한 실험인 것을 확인하였다.

나프탈렌승화법을 이용한 사각관 주위에서의 물질전달에 관한 연구 (A Study on the Mass Transfer from a Square Cylinder Using Naphthalene Sublimation Technique)

  • 유성연
    • 대한기계학회논문집
    • /
    • 제14권5호
    • /
    • pp.1300-1310
    • /
    • 1990
  • 본 연구에서는 양각과 레이놀즈수를 변화시켜 가면서 사각관 각 면에서의 국 소물질전닭계수를 측정하여, 유동의 정체, 가속, 박리, 재부착, 와류유출등의 복잡한 유동현상이 물질전달에 미치는 영향을 고찰하고자 한다. 한편 Igarashi의 열전달 측 정 결과와 비교하여 열전달과 물질전달의 유사성을 고찰하고, 복잡한 유동이나 3차원 유동영역에서의 열전달해석에 나프탈렌승화법을 이용한 물질전달실험의 응용 가능성을 검토하고자 한다.

가상질량과 저주파통과필터에 의한 햅틱 시스템의 안정성 영역에 관한 연구 (A Study for the Effect of a Virtual Mass with a Low-Pass Filter on a Stability of a Haptic System)

  • 이경노
    • 융복합기술연구소 논문집
    • /
    • 제7권2호
    • /
    • pp.25-30
    • /
    • 2017
  • This paper presents the effects of a virtual mass with a low-pass filter on the stability boundary of a virtual spring in the haptic system. In general, a haptic system consists of a haptic device, a sampler, a virtual impedance model and zero-order-hold. The virtual impedance is modeled as a virtual spring and a virtual mass. However the high-frequency noise due to the sampling time and the quantization error of sampled data may be generated when an acceleration is measured to compute the inertia force of the virtual mass. So a low-pass filter is needed to prevent the unstable behavior due to the high-frequency noise. A finite impulse response (FIR) filter is added to the measurement process of the acceleration and the effects on the haptic stability are simulated. According to the virtual mass with the FIR filter and the sampling time, the stability boundary of the virtual spring is analyzed through the simulation. The maximum available stiffness to guarantee the stable behavior is reduced, but simulation results still show that the stability boundary of the haptic system with the virtual mass is larger than that of the haptic system without the virtual mass.

Estimation of Phosphorus Concentration in Silicon Thin Film on Glass Using ToF-SIMS

  • Hossion, M. Abul;Murukesan, Karthick;Arora, Brij M.
    • Mass Spectrometry Letters
    • /
    • 제12권2호
    • /
    • pp.47-52
    • /
    • 2021
  • Evaluating the impurity concentrations in semiconductor thin films using time of flight secondary ion mass spectrometry (ToF-SIMS) is an effective technique. The mass interference between isotopes and matrix element in data interpretation makes the process complex. In this study, we have investigated the doping concentration of phosphorus in, phosphorus doped silicon thin film on glass using ToF-SIMS in the dynamic mode of operation. To overcome the mass interference between phosphorus and silicon isotopes, the quantitative analysis of counts to concentration conversion was done following two routes, standard relative sensitivity factor (RSF) and SIMetric software estimation. Phosphorus doped silicon thin film of 180 nm was grown on glass substrate using hot wire chemical vapor deposition technique for possible applications in optoelectronic devices. Using ToF-SIMS, the phosphorus-31 isotopes were detected in the range of 101~104 counts. The silicon isotopes matrix element was measured from p-type silicon wafer from a separate measurement to avoid mass interference. For the both procedures, the phosphorus concentration versus depth profiles were plotted which agree with a percent difference of about 3% at 100 nm depth. The concentration of phosphorus in silicon was determined in the range of 1019~1021 atoms/cm3. The technique will be useful for estimating distributions of various dopants in the silicon thin film grown on glass using ToF-SIMS overcoming the mass interference between isotopes.