• Title/Summary/Keyword: Mask angle

Search Result 101, Processing Time 0.03 seconds

Improved Margin of Absorber Pattern Sidewall Angle Using Phase Shifting Extreme Ultraviolet Mask (위상변위 극자외선 마스크의 흡수체 패턴의 기울기에 대한 오차허용도 향상)

  • Jang, Yong Ju;Kim, Jung Sik;Hong, Seongchul;Ahn, Jinho
    • Journal of the Semiconductor & Display Technology
    • /
    • v.15 no.2
    • /
    • pp.32-37
    • /
    • 2016
  • Sidewall angle (SWA) of an absorber stack in extreme ultraviolet lithography mask is considered to be $90^{\circ}$ ideally, however, it is difficult to obtain $90^{\circ}$ SWA because absorber profile is changed by complicated etching process. As the imaging performance of the mask can be varied with this SWA of the absorber stack, more complicated optical proximity correction is required to compensate for the variation of imaging performance. In this study, phase shift mask (PSM) is suggested to reduce the variation of imaging performance due to SWA change by modifying mask material and structure. Variations of imaging performance and lithography process margin depending on SWA were evaluated through aerial image and developed resist simulations to confirm the advantages of PSM over the binary intensity mask (BIM). The results show that the variations of normalized image log slope and critical dimension bias depending on SWA are reduced with PSM compared to BIM. Process margin for exposure dose and focus was also improved with PSM.

Evaluation of the effects of mandibular angle sagittal ostectomy and botulinum toxin type A treatment using facial golden mask (황금마스크를 이용한 하악각시상골절제술과 보툴리눔독소 치료법의 평가)

  • Shin, Seung-Kyu;Kim, Yong-Ha;Kim, Tae-Gon;Lee, Jun-Ho;Ahn, Ki-Young
    • Archives of Plastic Surgery
    • /
    • v.36 no.4
    • /
    • pp.469-474
    • /
    • 2009
  • Purpose: A lower facial contouring surgery has become a commonly performed procedure in Asia. Currently, mandibular angle sagittal ostectomy and botulinum toxin type A treatment are main procedures for aesthetic correction of a broad lower face. There are a few date to show the differences in the mandibular contouring changes between mandibular angle splitting ostectomy and botulinum toxin type A treatment. Facial golden mask is easy to apply, inexpensive, and relatively objective for evaluation of facial contour analysis. This study was designed specifically to compare the changes in lower face width after two different forms of lower facial contouring procedure using facial golden mask. Methods: Seventeen patients, aged 18 to 55 years (mean, 28.6 years), 15 women and 2 men, consented to the study and receive a contouring procedure of lower face. The patients were classified in to 2 groups. In group A, the sample consisted of 10 patients with a prominent squared mandibular angle and mandibular angle splitting ostectomy was performed. In group B, the sample consisted of 7 patients with masseteric hypertrophy and botulinum toxin type A treatment was performed. Photographs of the face were taken to record the facial change at preoperative and postoperative. The postoperative photographs were taken to considered maximal effect at 2 years after surgery in group A and 4.8 months after treatment in group B. The authors applied the facial golden mask to preoperative and postoperative photographs and horizontal ratio, which compares facial width with golden mask width, were calculated. We made an analysis of the result of horizontal ratio using SPSS. Results: Overall average horizontal ratio of pre- and postoperative photos of group A were 1.24 and 1.11, whereas overall average horizontal ratio of pre- and postoperative photos of group B were 1.19 and 1.12. The horizontal ratio decreased 10.24% in group A and 5.93% in group B. There was a statistically significant change in before and after treatment, but there was no significant change in comparing the group A and group B. Conclusions: The result from this study suggest that mandibular angle sagittal ostectomy and botulinum toxin type A treatment showed relatively satisfactory clinical effects on lower facial contouring treatment. There was no statistical significant difference within two lower facial contouring treatment. Facial golden mask is easy to apply, inexpensive, and relatively objective, so we think that facial golden mask is a good method for evaluation of lower facial contouring treatment.

Refilled mask structure for Minimizing Shadowing Effect on EUV Lithography

  • Ahn, Jin-Ho;Shin, Hyun-Duck;Jeong, Chang-Young
    • Journal of the Semiconductor & Display Technology
    • /
    • v.9 no.4
    • /
    • pp.13-18
    • /
    • 2010
  • Extreme ultraviolet (EUV) lithography using 13.5 nm wavelengths is expected to be adopted as a mass production technology for 32 nm half pitch and below. One of the new issues introduced by EUV lithography is the shadowing effect. Mask shadowing is a unique phenomenon caused by using mirror-based mask with an oblique incident angle of light. This results in a horizontal-vertical (H-V) biasing effect and ellipticity in the contact hole pattern. To minimize the shadowing effect, a refilled mask is an available option. The concept of refilled mask structure can be implemented by partial etching into the multilayer and then refilling the trench with an absorber material. The simulations were carried out to confirm the possibility of application of refilled mask in 32 nm line-and-space pattern under the condition of preproduction tool. The effect of sidewall angle in refilled mask is evaluated on image contrast and critical dimension (CD) on the wafer. We also simulated the effect of refilled absorber thickness on aerial image, H-V CD bias, and overlapping process window. Finally, we concluded that the refilled absorber thickness for minimizing shadowing effect should be thinner than etched depth.

Effect of Impact Angle on the Etching of Glass by Powder Blasting (Powder Blasting 을 이용한 유리의 표면부식시 분사각도의 영향)

  • 김광현;박경호;박동삼
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.349-354
    • /
    • 2001
  • In this study, we investigated the effect of the impacting ang1e of particles, the scanning times and the stand-off distance on the surface roughness and the weight-loss rate of samples with no mask, and the wall profile and overetching of samples with different mask pattern in powder blasting of soda-lime glass. The varying parameters were the different impact angles between 50$^{\circ}$ and 90$^{\circ}$, scanning times of nozz1e up to 40 and the stand-off distances 70mm and 100mm. The widths of mask pattern were 0.2mm, 0.5mm and 1mm. The powder was alumina sharp particles, WA#600. The mass flow rate of powder during the erosion test was fixed constant at 175g/min and the blasting pressure of powder at 0.2MPa

  • PDF

Effects of Fit Factor and Visual Acuity of Eyeglasses Wearers when Wearing Particulate Filtering Facepiece Respirators (안경착용자 방진마스크 착용 시 밀착계수와 착용시력에 미치는 영향)

  • Eoh, Won Souk;Shin, Chang Sup
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.3
    • /
    • pp.105-115
    • /
    • 2020
  • This study compares the difference of fit factors (FF) and visual acuity according to masks and eyeglasses preferences for 54 participants. We the precautions and behaviors of discomfort when wearing masks of eyewear wearers. Contact lens discomfort and priority action of complaints was investigated Glasses fitting factors is Optical Center Height(OH), Vertex Distance(VD) and Pantoscopic Angle(PA). We measured those factors and expressed by the ratio of standard point and change point. Quantitative fit factor was measured by Portacount Pro+ 8038. Also, we selected to 6 exercises among 8 exercises OSHA QNFT (Quantitative Fit testing) protocol to measure the fit factors. The pass/ fail criterion of FF was set at 100. Visual acuity(VA) test chart is developed by Chunsuk Han was used, Descriptive statistics was performed. Descriptive statistics(SAS ver 9.2), it is used geometric means, Wilcoxon analysis(P=0.05) When wearing the mask preferentially, fit factor(FF) was high according to the step of glasses fitting parameter. on the other hand, when the glasses first choice, the visual acuity(VA) was high. there was no significant difference. In the case of fit factor (FF), mask first choice/ glasses first choice is OH (p=0.671/ p=0.332), VD (p=0.602/ p=0.571) and PA (p=0.549/ p=0.607). Visual acuity (VA), mask first choice/ glasses first choice is OH (p=0.753/ p=0.386), VD (p=0.815/ p=0.557) and PA (p=0.856/ p=0.562). The workers of workplace and office chose glasses but occupational health workers and students chose mask. In case of discomforts, it was suggested to remove the mask and tolerate discomforts. The main discomforts and usual action of lens were dryness, hyperemia, foreign body sensation, ophthalmodynia, decreased vision and glasses wearing. Therefore, it is necessary to develop a mask wearing method education program considering glasses fitting and develop a hybrid model that minimizes inconvenience when wearing glasses and a mask at the same time.

Study of ion beam shaping of an anode-type ion source coupled with a Whenelt mask

  • Huh, Yunsung;Hwang, Yunseok;Kim, Jeha
    • Applied Science and Convergence Technology
    • /
    • v.27 no.4
    • /
    • pp.70-74
    • /
    • 2018
  • We fabricated an anode-type ion source driven by a charge repulsion mechanism and investigated its beam shape controlled by a Whenelt mask integrated at the front face of the source. The ion beam shape was observed to vary by changing the geometry of the Whenelt mask. As the angle of inclination of the Whenelt mask was varied from $40^{\circ}$ to $60^{\circ}$, the etched area at a thin film was reduced from 20 mm to 7.5 mm at the working distance of 286 mm, and the light transmittance through the etched surface was increased from 78% to 80%, respectively. In addition, for the step height difference, ${\Delta}$ between the inner mask and the outer mask of ${\Delta}=0$, -1 mm, and +1 mm, we observed the ion beam shape was formed to be collimated, diverged, and focused, respectively. The focal length of the focused beam was 269 mm. We approved experimentally a simple way of controlling the electric field of the ion beam by changing the geometry of the Whenelt mask such that the initial direction of the ion beam in the plasma region was manipulated effectively.

Fall Situation Recognition by Body Centerline Detection using Deep Learning

  • Kim, Dong-hyeon;Lee, Dong-seok;Kwon, Soon-kak
    • Journal of Multimedia Information System
    • /
    • v.7 no.4
    • /
    • pp.257-262
    • /
    • 2020
  • In this paper, a method of detecting the emergency situations such as body fall is proposed by using color images. We detect body areas and key parts of a body through a pre-learned Mask R-CNN in the images captured by a camera. Then we find the centerline of the body through the joint points of both shoulders and feet. Also, we calculate an angle to the center line and then calculate the amount of change in the angle per hour. If the angle change is more than a certain value, then it is decided as a suspected fall. Also, if the suspected fall state persists for more than a certain frame, then it is determined as a fall situation. Simulation results show that the proposed method can detect body fall situation accurately.

Development of a Inspection System for the Metal Mask Using a Vision System

  • Choi, Kyung-jin;Park, Chong-Kug;Lee, Yong-Hyun;Park, Se-Seung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.140.2-140
    • /
    • 2001
  • In this paper, we develop the system which inspects the metal mask using area scan camera and belu type xy-table and introduce its inspection algorithm. Thes whole area of the metal mask is divides into several inspection block and the sixe of a inspection block is decided by FOV(Field of View). To compare with the camera image of each block, the reference image is made by gerber file. The ratation angle of the metal mask is calculated through the linear equation that is substituted two end points of horizontal boundary of a specific hole in a camera image for. To calculate the position error caused by belt type xy-table, hough-transform using the distances among the holes in two images os used. The center of the reference image is moved as much as the calculated position error to be coincide with the camera image ...

  • PDF

Machinability in Oblique Powder Blasting of Glass (유리의 경사 미립분사가공시 가공성)

  • 박동삼;서태일
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.6
    • /
    • pp.28-34
    • /
    • 2004
  • The old technique of sandblasting which has been used for decoration of glass surface has recently been developed into a powder blasting technique for brittle materials such as glass, silicon and ceramics, capable of producing micro structures larger than 100${\mu}{\textrm}{m}$. In this study, we introduced oblique powder blasting, and investigated the effect of the impacting angle of particles, the scanning times and the stand-off distance on the surface roughness and the weight-loss rate of samples with no mask, and the wall profile and overetching of samples with different mask pattern in powder blasting of soda-lime glass. The varying parameters were the different impact angles between 50$^{\circ}$ and 90$^{\circ}$, scanning times of nozzle up to 40 and the stand-off distances 70mm and 100mm. The widths of mask pattern were 0.2mm, 0.5mm and 1mm. The powder was alumina sharp particles, WA #600. The mass flow rate of powder during the erosion test was fixed constant at 175g/min and the blasting pressure of powder at 0.2Mpa.

RETROSPECTIVE STUDY OF FACE MASK THERAPY (FACE MASK의 치료 효과에 대한 후향적 고찰)

  • Kim, Tae-Woo;Chang, Young-Il;Nahm, Dong-Seok
    • The korean journal of orthodontics
    • /
    • v.26 no.5 s.58
    • /
    • pp.547-556
    • /
    • 1996
  • The purpose of this study was to evaluate the skeletal, dental and soft tissue profile changes following the face mask therapy in growing skeletal class III malocclusion patients. The fifteen patients with the good results were selected among the patients who visited the Department of Orthodontics in Seoul National University Hospital. The mean age was 10.63(range 7.25-13.25) years and the mean treatment duration was 9.84(range 2.00-27.00) months. Lateral cephalograms were taken just before and after face mask application. After tracing the cephalograms, thirty five items(twety angular and fifteen linear) were measured. The differences before and after the face mask therapy were compared statistically by the paired t-test(p<0.05). The results were as follows : SNA and Co-A(effective maxillary length) increased significantly after using the face mask(p<0.001), which reflects the orthopedic changes of maxilla. SNB and Co-Gn(effective mandibular length) also showed an increase(p<0.01), which may be a result of the strong growth trends of the samples. FMA, SN-GoGn and Y-axis angle increased significantly(p<0.01), which means the backward and downward rotation of the mandible. This positional change seemed to have compensated an increase of effective mandibular length. There was no statistically significant difference in angulation of upper and lower incisors between pre-treatment and post-treatment(p>0.05). In soft tissue profile, the upper lip was positioned anteriorly(p<0.01) after treatment and approximated to the normal standards.

  • PDF