DOI QR코드

DOI QR Code

안경착용자 방진마스크 착용 시 밀착계수와 착용시력에 미치는 영향

Effects of Fit Factor and Visual Acuity of Eyeglasses Wearers when Wearing Particulate Filtering Facepiece Respirators

  • 어원석 (재단법인 정해산업보건연구소 교육센터) ;
  • 신창섭 (충북대학교 안전공학과)
  • Eoh, Won Souk (Jeonghae Institute of Occupational Health, Training center) ;
  • Shin, Chang Sup (Chungbuk National University, Department of Safety Engineering)
  • 투고 : 2020.03.13
  • 심사 : 2020.06.04
  • 발행 : 2020.06.30

초록

This study compares the difference of fit factors (FF) and visual acuity according to masks and eyeglasses preferences for 54 participants. We the precautions and behaviors of discomfort when wearing masks of eyewear wearers. Contact lens discomfort and priority action of complaints was investigated Glasses fitting factors is Optical Center Height(OH), Vertex Distance(VD) and Pantoscopic Angle(PA). We measured those factors and expressed by the ratio of standard point and change point. Quantitative fit factor was measured by Portacount Pro+ 8038. Also, we selected to 6 exercises among 8 exercises OSHA QNFT (Quantitative Fit testing) protocol to measure the fit factors. The pass/ fail criterion of FF was set at 100. Visual acuity(VA) test chart is developed by Chunsuk Han was used, Descriptive statistics was performed. Descriptive statistics(SAS ver 9.2), it is used geometric means, Wilcoxon analysis(P=0.05) When wearing the mask preferentially, fit factor(FF) was high according to the step of glasses fitting parameter. on the other hand, when the glasses first choice, the visual acuity(VA) was high. there was no significant difference. In the case of fit factor (FF), mask first choice/ glasses first choice is OH (p=0.671/ p=0.332), VD (p=0.602/ p=0.571) and PA (p=0.549/ p=0.607). Visual acuity (VA), mask first choice/ glasses first choice is OH (p=0.753/ p=0.386), VD (p=0.815/ p=0.557) and PA (p=0.856/ p=0.562). The workers of workplace and office chose glasses but occupational health workers and students chose mask. In case of discomforts, it was suggested to remove the mask and tolerate discomforts. The main discomforts and usual action of lens were dryness, hyperemia, foreign body sensation, ophthalmodynia, decreased vision and glasses wearing. Therefore, it is necessary to develop a mask wearing method education program considering glasses fitting and develop a hybrid model that minimizes inconvenience when wearing glasses and a mask at the same time.

키워드

참고문헌

  1. M. J. Kim, H. J. Kim, S. Y. Kim and C. K. Joo, "The Wear Status of Soft Continuous Wear Contact Lens", Journal of Korean Academy Optometry Society, Vol. 4, No. 1, pp. 11-15, 2005.
  2. J. Y. Choi, Y. Y. Song and J. C. Byun, "The Status of Contact Lens Wearing, Management and Eye Health Awareness among Female University Students in Jeju Area", J. Korea Ophthalmic Opt. Soc. Vol. 21, No. 3, pp. 203-214, 2016. https://doi.org/10.14479/jkoos.2016.21.3.203
  3. H. J. Kim, M. J. Kim, S. Y. Kim, J. S. Choi and C. K. Joo, "Relationship between Proteins Adsorption of Soft Contact Lens and Ocular Health", Journal of Korean Academy Optometry Society, Vol. 4, No. 1, pp. 16-20, 2005.
  4. J. Y. Kim, T. I. Kim and J. W. Jung, "Evaluation of Pigment Location in Tinted Contact Lenses and Effects on the Ocular Surface", Journal of Korean Optometry Society, Vol. 16, No. 1, pp. 1-4, 2017.
  5. D. H. Lee, S. H. Jo and J. E. Lee, "Clinical Study of Infectious Keratitis Caused by Contact Lens Wearing", Journal of Korean Optometry Society, Vol. 14, No. 1, pp. 22-26, 2015.
  6. H. S. Lee and K. C. Yoon, "Diagnosis and Treatment of Contact Lens-Related Dry Eye", Journal of Korean Optometry Society, Vol. 14, No. 1, pp. 4-6, 2015.
  7. S. S. Chang, H. W. Kim, H. A. Kim and Y. M. Roh, "Current Status of Respirator Usage and Analysis of Factors Causing Discontinued Use of Respirator in the Small - Scale Industries in Korea", Journal of Korean Society of Occupational and Environmental Hygiene, Vol. 8, No 1, pp. 133-145, 1998.
  8. W. S. Eoh and C. S. Shin, "The Effects of Interrelationship after Wearing between Respirators and Glasses Simultaneously", J. Korea Soc. Saf., Vol. 33, No. 1, pp. 47-53, 2018. https://doi.org/10.14346/JKOSOS.2018.33.1.47
  9. S. E. Lee and Y. H. Jin, "The Congruity between the Optical Center of Spectacles and Pupillary Center", J. Korean Oph. Soc. Vol. 40, No. 4, 1999.
  10. Y. R. Cho, H. J. Park, G. C. Yoo, J. S. Sung and J. M. Kim, "A Study on Fitting Analysis of Spectacle Wearers", J. Korean Vis. Sci. Vol. 2, No. 2, pp. 205-209, 2000.
  11. W. S. Eoh, Y. B, Choi and C. S. Shin, "Effects of Wearing between Respirators and Glasses Simultaneously on Physical and Visual Discomforts and Quantitative Fit Factors", J. Korean Soc. Saf., Vol. 33, No. 2, pp. 52-60, 2018. https://doi.org/10.14346/JKOSOS.2018.33.2.52
  12. H. J. Kim, K. J. Lee, K. C. Mah, S. J. Chung and H. J. Oh, "A Study on the Complaints of Spectacle Wearers", Journal of Korean Vis. Sci., Vol. 2, No. 2, pp. 197-203, 2000.
  13. P. J. Sung, "Optometric dispensing", 3rd Ed. Seoul : Daihakseorim, pp. 17, 2010.
  14. H. Kim, S. A. Park, J. S. Baek, J. H. Park and E. H. Lee, "Measurement of Horizontal and Vertical Prism Diopter according to Difference between the Optical Center and Pupil Center", J. Korea Opt. Soc., Vol. 16, No. 1, pp. 1-5, 2005.
  15. W. J. Park, S. W. Kim, H. Y. Hwang, D. S. Yu and J. S. Son, "Induced Prism by the Categories of Spectacle Frames", J. Korea Opt. Soc. Vol. 17, No. 3, pp. 311-319, 2012.
  16. J. H. Kim and H. J. Lee, "Clinical Estimation of Corrected with Change in Vertex Distance", J. Korean Oph. Opt., Vol. 15, No. 1, pp. 25-30, 2010.
  17. H. D. Kim, E. K. Park and K. H. Kim, "Clinical Evaluation between the Optical Center of Spectacles and Pupillary Center", J. Korea Opt. Soc. Vol. 8, No. 2, pp. 19-24, 2003.
  18. D. Y. Ko, K. H. Kim and D. H. Lee, "Clinical Evaluation on Variation of Face Form Angle of Eyewear", Journal of Korean Oph. Opt. Vol. 20, No. 4, pp. 477-484, 2015.
  19. H. W. Kim, J. E. Baek, H. K. Seo, J. E. Lee, J. P. Myong, S. J. Lee and J. H. Lee, "Comparison of Fit for Healthcare Workers Before and After Training with the N95 Mask", Journal of Korean Industrial Hygiene Association Journal, Vol. 24, No. 4, pp. 528-535, 2014.
  20. D. H. Kim, J. S. Kim and J. H. Mun, "The Contact Lens Wear in College Students in Korea", Journal of Korea Opt. Soc. Vol. 9, No. 2, pp. 233-239, 2004.
  21. D. J. Kim, M. C. Park, S. H. Lee, H. W. Kim, W. J. Lee and J. W. Cha, "The Influence of Office Indoor Air Qualitys on the Dry Eye Symptom of Contact Lens Wearers", Journal of Korea Opt. Soc. Vol. 17, No. 2, pp. 215-222, 2012.
  22. W. S. Eoh, "Effects of Donning Training of Resprirators on Fit Factor and Visual Accuity of Eyeglasses Wears", Chungbuk National University, pp. 117-124, 2018.
  23. J. Y. Lee, J. S. Jung and W. Y. Jang, "Development of Gas-mask Spectacles", Journal of Korea Opt. Soc. Vol. 13, No. 4, pp. 9-12, 2008.
  24. J. H. Kwon, "A Study of Disposable Micro Dust-mask Design for Bicycle Users", Journal of Digital Convergence, Vol. 16, No. 12, pp. 571-577, 2018. https://doi.org/10.14400/JDC.2018.16.12.571
  25. Y. S. Kang, "Research on Uncomfortableness and Customer Needs of Life-type Protection Mask - Focused on UV Protection Mask and Dust Protection Mask -", Journal of Korea Society Clothing and Textiles, Vol. 40, No. 1, pp. 114-130, 2016. https://doi.org/10.5850/JKSCT.2016.40.1.114
  26. D. A. Lombardi, S. K. Verma, M. J. Brennan and M. J. Perry, "Factors Influencing Worker use of Personal Protective Eyewear", Accident Analysis & Prevention, Vol. 41, No. 4, pp. 755-762, 2009. https://doi.org/10.1016/j.aap.2009.03.017