• Title/Summary/Keyword: Mandibular premolar

Search Result 366, Processing Time 0.023 seconds

Experimental study on the periodontal regenerative capacity of moldable synthetic peptide domain gel in degree III furcation defect of beagles (성견의 3급 이개부 병변에서 성형성 합성 펩타이드 젤의 치주재생 능력에 관한 실험적 연구)

  • Kim, Jeong-Beom;Park, Yoon-Jeong;Lee, Sang-Cheol;Kim, Tae-Il;Seol, Yang-Jo;Lee, Yong-Moo;Gu, Young;Rhyu, In-Chul;Han, Soo-Boo;Chung, Chong-Pyoung
    • Journal of Periodontal and Implant Science
    • /
    • v.38 no.4
    • /
    • pp.621-628
    • /
    • 2008
  • Purpose: Osteopontin is one of the major non-collagenous protein of hard tissue. Use of peptide domain of biologically active protein has some advantages. The objective of this experimental study is evaluation of periodontal regenerative potency of synthetic peptide gel which containing collagen binding domain of osteopontin in the degree III periodontal defect of beagle dogs. Material and Methods: Experimental degree III furcation defect was made in the mandibular third and fourth premolar of beagles. Regenerative material was applied during flap operation. 8 weeks after regenerative surgery, all animals were sacrificed and histomorphometric measurement was performed to calculate the linear percentage of the new cementum formation and the volume percentage of new bone formation. Result: The linear percent of new cementum formation was 41.6% at control group and 67.1% at test group and there was statistically significant difference. The volume percent of new bone formation was 52.1% at control group and 58.9% at test group. Conclusion: As the results of present experiment, synthetic peptide gel containing collagen binding domain of osteopontin significantly increase new bone and cementum formation in the degree III furcation defect of canine mandible.

Evaluation of Microleakage with Retrograde Filling Materials in Blood Contamination (혈액 오염된 역충전 재료의 미세누출 평가)

  • Cho, Hye-Jin;Moon, Jhong-Hyun;Chon, Seong-Min;Yu, Mi-Kyung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.1
    • /
    • pp.85-93
    • /
    • 2007
  • The purpose of this study was to evaluate the microleakage of root-end filling material filled in blood contaminated root-end cavity and self-etching adhesive placed over blood contaminated resected root apices without root-end preparation. Extracted, human maxillary incisors, canines and mandibular premolar were randomly divided into four groups of 15 teeth each. After canal preparation, resection of the apex and root-end preparation, MTA and IRM were filled in the root-end cavity (A and B group). After canal preparation and resection of the apex, Clearfil SE Bond and Prompt L-Pop were applied over the contaminated root-end surfaces (C and D group). The roots were then subjected to 15cm of water pressure to simulate periapical microleakage stress. Data were analyzed using one-way ANOVA. The results were as follows : 1. All groups showed a tendency of decreasing microleakage in process of time after 2weeks later except IRM group. 2. After 2 weeks and 1 month, MTA group showed less microleakage significantly than other groups(p<0.05). After 2 months, Prompt L-Pop group showed less microleakage significantly than other groups(p<0.05). 3. After 9 months, there were no significant differences among four groups(p>0.05). Thus it is considered that apical sealing using adhesives system without root-end preparation is good method in endodontic surgery.

Qualitative and quantitative evaluation of root injury risk potentially burdening insertion of miniscrew implants

  • Antoszewska, Joanna;Trzesniewska, Paulina;Kawala, Beata;Ludwig, Bjorn;Park, Hyo-Sang
    • The korean journal of orthodontics
    • /
    • v.41 no.2
    • /
    • pp.112-120
    • /
    • 2011
  • Objective: Microscrew implants (MSls) offer many advantages, but some complications are known to occur during their insertion. One of the most commonly reported complications is root injury. Our aim was to identify factors associated with root injury and to evaluate their qualitative and quantitative values. Methods: Thirty-five orthodontists placed MSls (AbsoAnchor$AbsoAnchor^{(R)}$, Dentos Co. Ltd, Daegu, Korea) in the upper jaw of typodonts, labially between the second premolar and the first molar, in low and high vertical positions. Root contacts were counted, and distances between MSI apices and roots were measured. Fear level of the orthodontists was surveyed before and after the experiment. Wilcoxon's test, chi-square test, and Mann-Whitney test were used for statistical analysis. Results: Overall root contact rate of MSI insertion was 23.57%. The root contact rate was significantly higher in MSls inserted at $90^{\circ}$ (45.71%) than at $30^{\circ}$ (1.43%). The distance between the dental root and MSI also increased significantly in MSls inserted at $30^{\circ}$. Mean fear level before MSI insertion (4.6) significantly decreased after insertion (3.2); the causative factors were risk of injury to dental root and maxillary sinus or mandibular canal. Conclusions: Root injury is relatively rare, and oblique angulation reduces the risk of root and MSI contact.

THE STRESS ANALYSIS OF SUPPORTING TISSUE AND IMPLANT ACCORDING TO CROWN RESTORATIVE MATERIALS AND TYPE OF IMPLANT (수복재료와 임플랜트 종류에 따른 임플랜트 및 지지조직의 응력분포)

  • Choi Chang-Hwan;Oh Jong-Suk;Vang Mong-Sook
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.1
    • /
    • pp.53-67
    • /
    • 2002
  • This study was aimed to analyze the stress distribution of implant and supporting tissue in single tooth implant restoration using Branemark $system^{(R)}$(Nobel Biocare, Gothenberg, Sweden) and Bicon system(Bicon Dental Implants, Boston, MA). Two dimensional finite element analysis model was made at mandibular first premolar area As a crown materials porcelain, ceromer, ADA type III gold alloy were used. Tests have been performed at 25Kgf vertical load on central fossa of crown portion and at 10Kgf load with $45^{\circ}$ lateral direction on cusp inclination. The displacement and stresses of implant and supporting structures were analyzed to investigate the influence of the crown material and the type of implant systems by finite element analysis. The results were obtained as follows : 1. The type of crown material influenced the stress distribution of superstructure, but did not influence that of the supporting alveolar bone. 2. The stress distribution of ceromer and type III gold alloy and porcelain is similar. 3. Stress under lateral load was about twice higher than that of vertical load in all occlusal restorative materials. 4. In Bicon system, stress concentration is similar in supporting bone area but CerOne system generated about 1.5times eater stress more in superstructure material. 5. In Branemark models, if severe occlusal overload is loaded in superstvucture. gold screw or abutment will be fractured or loosened to buffer the occlusal overload but in Bicon models such buffering effect is not expected, so in Bicon model, load can be concentrated in alveolar bone area.

The effect of different adhesive system applications on push-out bond strengths of glass fiber posts

  • Kivanc, Bagdagul Helvacioglu;Arisu, Hacer Deniz;Uctasli, Mine Betul;Okay, Tufan Can
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.3
    • /
    • pp.305-311
    • /
    • 2013
  • PURPOSE. Over the past years, the adhesion of fiber posts luted with simplified adhesive systems has been a matter of great interest. The aim of this study was to assess the post retentive potential of a self-adhesive resin cement using different adhesive systems to compare the push-out bond strengths of fiber posts. MATERIALS AND METHODS. The post spaces of 56 mandibular premolar roots were prepared and divided into 4 experimental groups and further divided into 2 subgroups according to testing time (n=7). The fiber posts (Rely X Fiber Post) were luted with a self-adhesive resin cement (RelyX Unicem) and one of the following adhesive systems: no adhesive, a total-etch adhesive resin (Single Bond), a two-step self-etch adhesive resin (Clearfil SE Bond) and a one-step self-etch adhesive resin (Clearfil S3 Bond). Each root was cut horizontally, and 1.5 mm thick six root segments were prepared. Push-out tests were performed after one week or three months (0.5 mm/min). Statistical analysis were performed with three-way ANOVA (${\alpha}$=.05). RESULTS. Cervical root segments showed higher bond strength values than middle segments. Adhesive application increased the bond strength. For one week group, the total-etch adhesive resin Single Bond showed higher bond strength than the self-adhesive resin cement RelyX Unicem applied without adhesive resin at middle region. For 3 months group, the two-step self-etch adhesive resin Clearfil SE Bond showed the highest bond strength for both regions. Regarding the time considered, Clearfil SE Bond 3 months group showed higher bond strength values than one week group. CONCLUSION. Using the adhesive resins in combination with the self-adhesive resin cement improves the bond strengths. The bond strength values of two-step self-etch adhesive resin Clearfil SE Bond improved as time passes.

A CEPHALOMETRIC STUDY ON MESIODISTAL AXIAL INCLINATION OF POSTERIOR TEETH IN OPEN BITE AND DEEP BITE (개방교합과 과개교합에서 구치의 근원심 치축경사도에 관한 두부방사선계측학적 연구)

  • Jeon, Sang-Beom;Kim, Jin-Beom;Shon, Woo-Sung
    • The korean journal of orthodontics
    • /
    • v.23 no.3 s.42
    • /
    • pp.391-403
    • /
    • 1993
  • For the purpose of investigating mesiodistal axial inclination of posterior teeth in normal occlusion group, open bite and deep bite group and investigating the correlationship between the axial inclination of posterior teeth and overbite of anterior teeth, a cephalometric study was performed on the subjects consisted of normal occlusion group(40), open bite group(71 : Angle's Class I, Class II, division 1 25, Class III 25) and deep bite group(64 : Angle's Class I 23, Class II, division 1 21, Class III 20). Mesiodistal axial inclination of posterior teeth to occlusal, mandibular and palatal plane were measured. The findings of this study were as follows : 1. Upper and lower posterior teeth were more mesially inclined to occlusal plane in open bite group than in deep bite group. 2. Lower posterior teeth were more mesially inclined in deep bite group than in open bite group in Angle's Class II, division 1 malocclusion but there were no significant differences in Angle's Class I and Class III malocclusion. 3. There was no significant correlationship between the axial inclination of posterior teeth to each plane and overbite of anterior teeth in open bite group. 4. There was a significant correlationship between the axial inclination of upeer and lower second premolar to occlusal plane and overbite of anterior teeth in Angle's Class I, Class II, division 1 and Class III malocclusion.

  • PDF

THREE DIMENSIONAL FINITE ELEMENT STRESS ANALYSIS OF FIVE DIFFERENT TAPER DESIGN IMPLANT SYSTEMS (3차원 유한요소법적 분석을 이용한 5종의첨형 임플랜트에 발생하는 응력의 비교연구)

  • Byun, Sang-Ki;Park, Won-Hee;Lee, Young-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.5
    • /
    • pp.584-593
    • /
    • 2006
  • Statement of problem : Dental implant which has been developed gradually through many experiments and clinical applications is presently used to various dental prosthetic treatments. To conduct a successful function of implant prosthesis in oral cavity for a long time, it is important that not only structure materials must have the biocompatibility, but also the prosthesis must be designed for the stress, which is occurred in occlusion, to scatter adequately of load support. Therefore, it is essential to give the consideration about the stress analysis of supporting tissues for higher successful rates. Purpose : Recently, many implant manufacturing company produce various taper design of root form implant, the fixture is often selected. However, the stress analysis of taper form fixture still requires more studies. Material and method : This study we make the element models that five implant fixture; Branemark system(Nobel Biocare, Gothenberg, Sweden), Camlog system(Altatec, Germany), Astra system(Astra Tech, Sweden), 3i system(Implant Innovations Inc, USA), Avana system(Osstem, Korea) were placed in the area of mandibular first premolar and prosthesis fabricated, which we compared with stress distribution using the three-dimension finite element analysis under two loading condition. Results : This study compares the aspect of stress distribution of each system with the standard of Von mises stress, among many resulted from finite element analysis so that this research gets the following results. 1. In all implant system, oblique loading of maximum Von mises stress of implant, alveolar bone and crown is higher than vertical loading of those. 2. Regardless of loading conditions and type of system, cortical bone which contacts with implant fixture top area has high stress, and cancellous bone has a little stress. under the vertical loading, maximum Von mises stress is more higher in order of Branemark, Camlog, Astra, 3i, Avana. under the horizontal loading, maximum Von mises is more higher in order of Camlog, Branemark, Astra, 3i, Avana.

REGENERATIVE CAPACITY OF DEMINERALIZED BONE GRAFT AND GUIDED TISSUE REGENERATION ON DEHISCED ALVEOLAR BONE ADJACENT TO DENTAL IMPLANT (탈회이식골과 유도조직재생용 차폐막이 인공치아 매식채 주위의 골열개창 치유에 미치는 효과)

  • Chung, Kyeong-Uk;Choi, Sang-Mook
    • Journal of Periodontal and Implant Science
    • /
    • v.25 no.2
    • /
    • pp.341-356
    • /
    • 1995
  • The purpose of this study was to evaluate the effect of demineralized freeze dried bone and demineralized bone gel with guided tissue regeneration treatment around titanium implants with dehisced bony defects and also evaluate space maintaining capacity of demineralized bone gel type and DFDB powder type under e-PTFE membrane. In 3 Beagle dogs, mandibular premolar was extracted and four peri-implant osteotomies were formed for dehiscence. After insertion of implants, the four peri-implant defects were treated as follows. 1) In control group. no graft material and barrier membrane were applied. 2) In experimental group.1, the site was covered only with the e-PTFE membrane. 3) In experimental group 2,received DFDB powder and covered by the e-PTFE membrane. 4) In experimental group 3, demineralized bone gel and e-PTFE membrane were used. By random selection, animals were sacrificed at 4, 8, 12 weeks. The block sectioned specimens were prepared for decalcified histologic evaluation(hematoxylin and eosin staining) and undecalcified histologic evahiation(Von Kossa's and toluidine blue staining) with light microscopy. The results of this study were as follows. 1) In control group, there was a little new bone formation and connective tissue was completely filled in the defect area. 2) Experimental group 1 showed lesser quantity of bone formation as compared to the bone grafted group. Thin vertical growth of new bone formation around implant fixture was shown. 3) Experimental group 2 showed thick bucco-lingual growth of new bone formation and grafted bone particles were almost resorbed in 12 week group. 4) In experimental group 3, most grafted bone particles were not resorbed in 12 week group and thick bucco-lingual bone formation was shown in dehisced defect base area. 5) There was no remarkable differences in space making capacity and new bone formation procedure between demineralized freeze-dried bone powder type and demineralized bone gel type.

  • PDF

LANGERHANS CELL HISTIOCYTOSIS IN MANDIBLE : CASE REPORT (하악골에 발생한 Langerhans Cell Histiocytosis 환아의 증례보고)

  • Yoon, Hyun-Joo;Lee, Jae-Ho;Yoon, Jung-Hoon;Lee, Jong-Gap
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.1
    • /
    • pp.8-11
    • /
    • 2001
  • Langerhans Cell Histiocytosis (LCH) is characterized by proliferation of Langerhans cells. The clinical manifestation varies from solitary bone lesion to multi-system, life threatening disorder. The younger the patient is and the more system is involved, the worse the prognosis is. The jaw is involved $10\sim20$ percent of all LCH and it is involved usually in early stage of LCH. In this case the patient is three years old girl who suffered from pain of whole mandibular body and histological examination confirmed the diagnosis LCH. She is referred to pediatrics and managed with combined chemotherapy. Due to the possibility of recurrence, we follow up the girl and she need orthodontic and prosthodontic treatment in the future because of the loss of lower left 2nd premolar. We report this case because early recognized LCH in dental hospital result in good prognosis.

  • PDF

A Study on the Accuracy of the Electronic Apex Locator Using a Micro-Computed Tomography (미세단층촬영기(Micro-CT)를 이용한 전자 근관장 측정기의 정확성에 관한 연구)

  • Chun, Keyoung-Jin;Kim, Yang-Soo;Nam, Tae-Kye
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.8 s.197
    • /
    • pp.116-121
    • /
    • 2007
  • The length of root canal has to be measured for endodontic treatment. Several electronic apex locators were developed to measure the length of root canal by other researchers. And their accuracies were verified by X-ray or micrometer method. But these methods did not consider the non-linear bends of pulp and had ${\pm}0.5mm$ error which was large enough to measure the length of root canal. The purpose of this study is the introduction of a new method to measure the length of root canal and the verification of the accuracy of an electronic apex locator using a Micro-CT. The length of root canal of 6 teeth were measured with the electronic apex locator. When the electronic apex locator reads 0.5, 0.6, 0.7, 0.8, 0.9 and 1.0 mm length of the file which was inserted in the hole of the tooth to measure the length of root canal. The average (${\pm}$Standard deviation) length of root canal of 6 teeth measured by the Micro-CT was $0.49{\pm}0.03,\;0.59{\pm}0.04,\;0.68{\pm}0.03,\;0.78{\pm}0.03,\;0.90{\pm}0.04\;and\;1.01{\pm}0.03mm$, respectively. The maximum error of the electronic apex locator was 0.06 mm.