References
- Kanomi R. Mini-implant for orthodontic anchorage. J Clin Orthod 1997;31:763-7.
- Park HS. The skeletal cortical anchorage using titanium microscrew implants. Korean J Orthod 1999;29:699-706.
- Melsen B, Verna C. Miniscrew implants: The Aarhus anchorage system. Semin Orthod 2005;11:24-31. https://doi.org/10.1053/j.sodo.2004.11.005
- Papadopoulos MA, Tarawneh F. The use of miniscrew implants for temporary skeletal anchorage in orthodontics: a comprehensive review. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2007;103:e6-15. https://doi.org/10.1016/S1079-2104(07)00249-1
- Park HS, Kwon OW, Sung JH. Nonextraction treatment of an open bite with microscrew implant anchorage. Am J Orthod Dentofacial Orthop 2006;130:391-402. https://doi.org/10.1016/j.ajodo.2005.07.014
- Park HS, Kwon OW, Sung JH. Microscrew implant anchorage sliding mechanics. World J Orthod 2005;6:265-74.
- Kravitz ND, Kusnoto B. Risks and complications of orthodontic miniscrews. Am J Orthod Dentofacial Orthop 2007;31(4 Suppl):S43-51.
- Cho UH, Yu W, Kyung HM. Root contact during drilling for microimplant placement. Affect of surgery site and operator expertise. Angle Orthod 2010;80:130-6. https://doi.org/10.2319/011509-535.1
- Asscherickx K, Vannet BV, Wehrbein H, Sabzevar MM. Root repair after injury from mini-screw. Clin Oral Implants Res 2005;16:575-8. https://doi.org/10.1111/j.1600-0501.2005.01146.x
- Lee YK, Kim JW, Baek SH, Kim TW, Chang YI. Root and bone response to the proximity of a mini-implant under orthodontic loading. Angle Orthod 2010;80:452-8. https://doi.org/10.2319/070209-369.1
- Schnelle MA, Beck FM, Jaynes RM, Huja SS. A radiographic evaluation of the availability of bone for placement of miniscrews. Angle Orthod 2004;74:832-7.
- Kuroda S, Yamada K, Deguchi T, Hashimoto T, Kyung HM, Takano-Yamamoto T. Root proximity is a major factor for screw failure in orthodontic anchorage. Am J Orthod Dentofacial Orthop 2007;131(4 Suppl):S68-73. https://doi.org/10.1016/j.ajodo.2006.06.017
- Hernandez LC, Montoto G, Puente Rodriguez M, Galban L, Martinez V. 'Bone map' for a safe placement of miniscrews generated by computed tomography. Clin Oral Implants Res 2008;19:576-81. https://doi.org/10.1111/j.1600-0501.2007.01507.x
- Hu KS, Kang MK, Kim TW, Kim KH, Kim HJ. Relationships between dental roots and surrounding tissues for orthodontic miniscrew installation. Angle Orthod 2009;79:37-45. https://doi.org/10.2319/083107-405.1
- Hembree M, Buschang PH, Carrillo R, Spears R, Rossouw PE. Effects of intentional damage of the roots and surrounding structures with miniscrew implants. Am J Orthod Dentofacial Orthop 2009;135:280.e1-9. https://doi.org/10.1016/j.ajodo.2008.06.022
- Brisceno CE, Rossouw PE, Carrillo R, Spears R, Buschang PH. Healing of the roots and surrounding structures after intentional damage with miniscrew implants. Am J Orthod Dentofacial Orthop 2009;135:292-301. https://doi.org/10.1016/j.ajodo.2008.06.023
- Renjen R, Maganzini AL, Rohrer MD, Prasad HS, Kraut RA. Root and pulp response after intentional injury from miniscrew placement. Am J Orthod Dentofacial Orthop 2009;136:708-14. https://doi.org/10.1016/j.ajodo.2007.12.031
- Andreasen JO, Kristerson L. The effect of limited drying or removal of the periodontal ligament. Periodontal healing after replantation of mature permanent incisors in monkeys. Acta Odontol Scand 1981;39:1-13. https://doi.org/10.3109/00016358109162253
- Kang YG, Kim JY, Lee YJ, Chung KR, Park YG. Stability of mini-screws invading the dental roots and their impact on the paradental tissues in beagles. Angle Orthod 2009;79:248-55. https://doi.org/10.2319/122007-413.1
- Poggio PM, Incorvati C, Velo S, Carano A. "Safe zones": a guide for miniscrew positioning in the maxillary and mandibular arch. Angle Orthod 2006;76:191-7.
- Park HS, Bae SM, Kyung HM, Sung JH. Micro-implant anchorage for treatment of skeletal Class I bialveolar protrusion. J Clin Orthod 2001;35:417-22.
- Park HS, Jeong SH, Kwon OW. Factors affecting the clinical success of screw implants used as orthodontic anchorage. Am J Orthod Dentofacial Orthop 2006;130:18-25. https://doi.org/10.1016/j.ajodo.2004.11.032
- Miyawaki S, Koyama I, Inoue M, Mishima K, Sugahara T, Takano-Yamamoto T. Factors associated with the stability of titanium screws placed in the posterior region for orthodontic anchorage. Am J Orthod Dentofacial Orthop 2003;124:373-8. https://doi.org/10.1016/S0889-5406(03)00565-1
- Antoszewska J, Papadopoulos MA, Park HS, Ludwig B. Five-year experience withorthodontic miniscrew implants: a retrospective investigation of factors influencing success rates. Am J Orthod Dentofacial Orthop 2009;136:158.e1-10. https://doi.org/10.1016/j.ajodo.2009.03.032
Cited by
- Accuracy of a cone beam computed tomography-guided surgical stent for orthodontic mini-implant placement. vol.82, pp.2, 2011, https://doi.org/10.2319/060811-374.1
- Insertion torque recordings for the diagnosis of contact between orthodontic mini-implants and dental roots: protocol for a systematic review vol.4, pp.None, 2011, https://doi.org/10.1186/s13643-015-0014-6
- Insertion torque recordings for the diagnosis of contact between orthodontic mini-implants and dental roots: a systematic review vol.5, pp.1, 2011, https://doi.org/10.1186/s13643-016-0227-3
- Evaluation of miniscrew angulation in the posterior maxilla using cone-beam computed tomographic image vol.23, pp.1, 2018, https://doi.org/10.1590/2177-6709.23.1.046-053.oar