• 제목/요약/키워드: Main Gate

검색결과 326건 처리시간 0.024초

Series Compensated Step-down AC Voltage Regulator using AC Chopper with Transformer

  • Ryoo, H.J.;Kim, J.S.;Rim, G.H.
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제5B권3호
    • /
    • pp.277-282
    • /
    • 2005
  • This paper describes a step-down AC voltage regulator using an AC chopper and auxiliary transformer, which is a series connected to the main input. The detail design of the AC regulator, logic and PWM pattern of the AC chopper is described and the three-phase AC regulator using two single­phase AC choppers with a three transformer configuration is proposed for three-phase application. The proposed three-phase system has the advantages of lower system cost due to reduced switch number and gate driver circuit as well as advantages of decreased size and weight because it uses a series compensated scheme. The proposed AC regulator has many benefits such as fast voltage control, high efficiency and simple control logic. Experimental results indicate that it can be used as a step-down AC voltage regulator for power saving purposes very efficiently.

A Study On the Retention Time Distribution with Plasma Damage Effect

  • Yi Jae Young;Szirmay Laszlo;Yi Cheon Hee
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2004년도 학술대회지
    • /
    • pp.460-462
    • /
    • 2004
  • The control of the data retention time is a main issue for realizing future high density dynamic random access memory. There are several leakage current mechanisms in which the stored data disappears. The mechanisms of data disappear is as follow, 1 )Junction leakage current between the junction, 2) Junction leakage current from the capacitor node contact, 3)Sub-threshold leakage current if the transfer transistor is affected by gate etch damage etc. In this paper we showed the plasma edge damage effect to find out data retention time effectiveness. First we measured the transistor characteristics of forward and reverse bias. And junction leakage characteristics are measured with/without plasma damage by HP4145. Finally, we showed the comparison TRET with etch damage, damage_cure_RTP and hydrogen_treatment. As a result, hydrogen_treatment is superior than any other method in a curing plasma etch damage side.

  • PDF

MMC기반의 전압형 HVDC 밸브의 여유율 결정 (The Valve Redundancy Determination for HVDC Converter based on Modular Multilevel Converter)

  • 김찬기;최순호;강지원;윤용범
    • 전력전자학회논문지
    • /
    • 제21권4호
    • /
    • pp.328-334
    • /
    • 2016
  • This paper examines the reliability of a VSC-HVDC valve based on a modular multilevel converter (MMC) HVDC system. The main objective of this paper is to determine the redundancy of the MMC valve. Several prediction methods are introduced, but the binomial failure method is selected to be used. To determine the availability and reliability prediction of MMC valve, which comprises a DC/DC converter, a gate driver, a capacitor, and an IGBT, the failure data of the MMC module are used as the tracking data according to the experimental result. This method uses a simplified equation to find the valve redundancy by transforming the binomial function to De Moivre's formula. This method is the first to be used to find the valve margin.

주권선 전류검출에 의한 단상유도전동기의 구동시스템 구현 (The Starting System Implementation of SPIM with Detecting Main Winding Current)

  • 최낙일;박수강;오금곤;백형래;임양수;오기진
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1997년도 전력전자학술대회 논문집
    • /
    • pp.166-170
    • /
    • 1997
  • A Single phase induction motor is the predominant fractional horsepower power rated, extensively used in domestic and industrial application. For example, these motors provide the motive power to washing machines, fans, refrigerators, etc. In this paper, single phase induction motor input current was detected by a small current transformer and determined TRIAC gate signal by using op-amp analog circuit. The soft-start strategy is based on limited auxiliary current angle during starting period in the closed-loop control. The Simulation and experimental result show the motor's starting characteristics of the proposal starting system and are compared with centrifugal switch starting motor.

  • PDF

Effect of Coincidence Gamma-ray Spectroscopy to the Reduction of Background Spectrum

  • Kim, Taewook;Changsoo Yoou;Chongmook park;Kim, Byungtae
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1998년도 춘계학술발표회논문집(2)
    • /
    • pp.464-469
    • /
    • 1998
  • A coincidence gamma-ray spectroscopy method was applied to reduce the background radioactivity for measuring the activity of radioisotopes in a sample in the presence of environmental natural radioactivity. A HPGe detector was used for the coincident spectrum as a main detector and a NaI(Tl) scintillation detector for gating purposes as an associated detector. For coincidence spectroscopy the whole energy spectrum of associated detector was used instead of gate signals. The coincident events obtained from the gating spectrum was evaluated by a coincidence computer program in this study instead of timing circuit. In this work, the background of detection environment was reduced to factor 100 and peaks to be determined was reduced to factor 30 using the coincidence gamma-ray spectroscopy.

  • PDF

Short-circuit Protection for the Series-Connected Switches in High Voltage Applications

  • Tu Vo, Nguyen Qui;Choi, Hyun-Chul;Lee, Chang-Hee
    • Journal of Power Electronics
    • /
    • 제16권4호
    • /
    • pp.1298-1305
    • /
    • 2016
  • This paper presents the development of a short-circuit protection mechanism on a high voltage switch (HVS) board which is built by a series connection of semiconductor switches. The HVS board is able to quickly detect and limit the peak fault current before the signal board triggers off a gate signal. Voltage clamping techniques are used to safely turn off the short-circuit current and to prevent overvoltage of the series-connected switches. The selection method of the main devices and the development of the HVS board are described in detail. Experimental results have demonstrated that the HVS board is capable of withstanding a short-circuit current at a rated voltage of 10kV without a di/dt slowing down inductor. The corresponding short-circuit current is restricted to 125 A within 100 ns and can safely turn off within 120 ns.

자동 분수공의 개발 (Development of the Automatic Turnout)

  • 저하우;이남호;김성준;최진용;한형근;한휘남
    • 한국농공학회지
    • /
    • 제36권4호
    • /
    • pp.33-38
    • /
    • 1994
  • Floating-type automatic turnout was developed for the purpose of reducing labor cost and labor-working hours related to turnout management. The point of automation is to use a flexible-float within the turnout. The weight of float is changed by emptying and filling with water at the beginning and ending of irrigation. The turnout is controlled to open and close small bole on the float bottom using electromagnets. With the weight control of float. the gate of turnout is opened by the empty float to begin irrigatiom and is closed by the filled float to stop irrigation. The turnout was designed to be operated by the main computer and to minimize electric power consumption by sending an electric current at the beginning and ending of irrigation. The functional experiment was succesfully carried out and the rating curves for both free overflow condition and submerged flow condition were derived.

  • PDF

FPGA Based PWM Generator for Three-phase Multilevel Inverter

  • ;전태원;김흥근;노의철
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.225-227
    • /
    • 2008
  • This paper deals with the implementation on a Field Programmable Gate Array (FPGA) of PWM switching patterns for a voltage multilevel inverter. The reference data in main microcontroller is transmitted to the FPGA through 16 general purpose I/O ports. Herein, three-phase reference voltage signals are addressed by the last 2-bit (bit 15-14) and their data are assigned in remaining 14-bit, respectively. The carrier signals are created by 16-bit counter in up-down counting mode inside FPGA according to desirable topology. Each reference signal is compared with all carrier signals to generate corresponding PWM switching patterns for control of the multilevel inverter. Useful advantages of this scheme are easy implementation, simple software control and flexibility in adaptation to produce many PWM signals. Some simulations and experiments are carried out to validate the proposed method.

  • PDF

조선후기 경기도 지역 도시의 건축 및 도시적 특성에 관한 연구 - 상업발전이 시가지 가로에 미친 영향 - (A Study on the Characteristics of Architecture and Urban Form of Kyonggi-do Area in the Late Chosun Dynasty)

  • 김동욱;이상구
    • 건축역사연구
    • /
    • 제7권4호
    • /
    • pp.9-27
    • /
    • 1998
  • The urban form of Korean cities significantly changed in the late Chosun dynasty. The influence of commercial development was the main cause of these changes. Commerce became a important function of existing cities, and the new type of commercial towns emerged at the important spots of traffic routes. In both cases streets became dominant element of urban form. Mainly commercial buildings aggregated along the streets, and to obtain higher land use intensity shape of lots became narrow and deep. Koyang(高陽) shows the most significant example of this new type of lot and lot pattern. Approximately 30 narrow and deep type of lots lined on each side of street forming about 390 meters long linear commercial town. Similar examples were found at the outside of south gate of Suwon(水原), Nuwon(樓院), and Pangyo(板橋).

  • PDF

전력선 통신을 이용한 인터넷 기반 원격 제어 시스템 (Internet-Based Remote Control System Using Power Line Communication)

  • 차주헌;전희연;김재덕;김근영
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.523-528
    • /
    • 2001
  • In this paper, we describe the internet-based remote home automation system that con control and manage home appliances or digital devices bi-directionally through Internet. The platform-independency of VRML and Java applet enables users to access their home appliances and to check current state of them in t he virtual reality environment. The main focus is on three aspects. One is on the virtual reality technology to support the user interface efficiently by using 3D GUI in web-browser. Another is on the system architecture that consists of Home server and its manager server called Gate server in this paper. These servers have been implemented by Java RMI which is the basic single programming interface for distribution of objects and services using Java technology. The third, remote PLC controller and each digital devices are composed of home networking by PLC using CEBus protocol.

  • PDF