• Title/Summary/Keyword: Magnetic Object

Search Result 219, Processing Time 0.031 seconds

Design of Magnetic Circuit with Minimum Leakage Using Response Surface Methodology (반응표면분석법을 이용한 자계누설 최소화 설계)

  • Park, Jin-Hun;Kwon, Jung-Hak;Hwang, Sang-Mun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.1
    • /
    • pp.27-33
    • /
    • 2010
  • This paper focuses on the design of microspeakers with minimum flux leakage, for use in radiotelegraphy. The response surface methodology (RSM) is applied as the optimization technique for obtaining a large magnetic force and a small flux leakage on diaphragm. The object functions of this optimization are the magnetic force and the flux leakage along three factors; pole piece thickness, magnet grade and yoke thickness, which are determined by the design of the experiment. The magnetic force and the flux leakage are calculated for each condition and optimized by results evaluated with RSM. For a pole piece thickness of 0.9 mm, a magnet grade of N42H and a yoke thickness of 0.75 mm, the magnetic force is satisfied as initial model and flux leakage is decreased to 11.8% than initial model.

Robust Stability Analysis of Hybrid Magnetic Bearing System (하이브리드 자기베어링 시스템의 강인 안정도 해석)

  • Sung, Hwa-Chang;Park, Jin-Bae;Tark, Myung-Hwan;Joo, Young-Hoon
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.21 no.3
    • /
    • pp.372-377
    • /
    • 2011
  • This paper propose the robust stability algorithm for controlling a hybrid magnetic bearing system. The control object in the magnetic bearing system enables the rotor to rotate without any physical contact by using magnetic force. Generally, the system dynamics of the magnetic bearing system has severe nonlinearity and uncertainty so that it is not easy to obtain the control objective. For solving these problems, we propose the fuzzy modelling and robust control algorithm for hybrind magnetic bearing system. The sufficient conditions for robust controller are obtained in terms of solutions to linear matrix inequalities (LMIs). Simulation results for HMB are demonstrated to visualize the feasibility of the proposed method.

Inverse Scattering of Two-Dimensional Objects Using Linear Sampling Method and Adjoint Sensitivity Analysis

  • Eskandari, Ahmadreza;Eskandari, Mohammad Reza
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.308-313
    • /
    • 2015
  • This paper describes a technique for complete identification of a two-dimensional scattering object and multiple objects immersed in air using microwaves where the scatterers are assumed to be a homogenous dielectric medium. The employed technique consists of initially retrieving the shape and position of the scattering object using a linear sampling method and then determining the electric permittivity and conductivity of the scatterer using adjoint sensitivity analysis. Incident waves are assumed to be TM (Transverse Magnetic) plane waves. This inversion algorithm results in high computational speed and efficiency, and it can be generalized for any scatterer structure. Also, this method is robust with respect to noise. The numerical results clearly show that this hybrid approach provides accurate reconstructions of various objects.

Design and manufacture of mini loop coil magnetic curer for peripheral nervous system treatment (말초신경계 치료를 위한 미니 Loop - 코일 삽입형 자기치료시스템의 설계 및 제작)

  • Kim, Whi-Young
    • Proceedings of the KIEE Conference
    • /
    • 2007.04c
    • /
    • pp.153-155
    • /
    • 2007
  • It is as result that study to apply mini magnet nerve curer in peripheral nervous system disease treatment. Design and embodied action power and Control Unit in cylinder form of magnet roof object firstly. Yielded service area about special quality of probe of roof object cylinder style and treatment area dimension and distance of treatment pulse secondly. Embody pulse forming course energy value by Probe's form by third, could embody treatment pulse by disease. Specially, through a special quality experiment, saved Damping pulse form and treatment pulse form etc. variously Lately, embodied this to aid a little in disease treatment that follow that there is no invasion that there is no stimulation by medicine development Go amplitude treatment pulse (traditional magneto-therapy of greatly great that strong.) does curative effect greatest at short time and becomes thought that demand is magnified greatly at the future in this research.

  • PDF

Mini loop coil magnetic curer for peripheral nervous system treatment (말초신경계 치료를 위한 미니 Loop - 코일 삽입형 자기치료기)

  • Kim, Whi-Young
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.49-51
    • /
    • 2007
  • It is as result that study to apply mini magnet nerve curer in peripheral nervous system disease treatment. Design and embodied action power and Control Unit in cylinder form of magnet roof object firstly. Yielded service area about special quality of probe of roof object cylinder style and treatment area dimension and distance of treatment pulse secondly. Embody pulse forming course energy value by Probe's form by third, could embody treatment pulse by disease. Specially, through a special quality experiment, saved Damping pulse torn and treatment pulse form etc. variously. Lately, embodied this to aid a little in disease treatment that follow that there is no invasion that there is no stimulation by medicine development. Go amplitude treatment pulse (traditional magneto-therapy of greatly great that strong) does curative effect greatest at short time and becomes thought that demand is magnified greatly at the future in this research.

  • PDF

APPLICATIONS OF ASYMMETRIC HYSTERESIS LOOPS IN AMORPHOUS ALLOYS

  • Jr., C.D. Graham;Shin, K-H.;Zhou, Peter Y.
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.5
    • /
    • pp.579-582
    • /
    • 1995
  • The use of amorphous magnetic alloys as tags or targets in electronic article surveillance systems such as antishoplifting desvices is briefly reviewed. Improved tags became possible with the discovery in 1988 of asymmetric magnetization reversal (AMR) in certain amorphous alloys annealed in applied field approximately equal to the earth's field. These asymmetric hysteresis loops are highly unusual, if not unique, and so greatly diminish the probability of false alarms in a detection system. furthermore, the jump field Hj, which is the coercive field in negative applied fields, can be controlled over a useful range by controlling the field applied to the sample during annealing. By applying several tags to an object, each with a different jump field, it is possible to identify the object with a numeric code that can be remotely read by nonoptical means.

  • PDF

Embedded Object-Oriented Micromagnetic Frame (OOMMF) for More Flexible Micromagnetic Simulations

  • Kim, Hyungsuk;You, Chun-Yeol
    • Journal of Magnetics
    • /
    • v.21 no.4
    • /
    • pp.491-495
    • /
    • 2016
  • We developed an embedded Object-Oriented Micromagnetic Frame (OOMMF) script schemes for more flexible simulations for complex and dynamic mircomagnetic behaviors. The OOMMF can be called from any kind of softwares by system calls, and we can interact with OOMMF by updating the input files for next step from the output files of the previous step of OOMMF. In our scheme, we set initial inputs for OOMMF simulation first, and run OOMMF for ${\Delta}t$ by system calls from any kind of control programs. After executing the OOMMF during ${\Delta}t$, we can obtain magnetization configuration file, and we adjust input parameters, and call OOMMF again for another ${\Delta}t$ running. We showed one example by using scripting embedded OOMMF scheme, tunneling magneto-resistance dependent switching time. We showed the simulation of tunneling magneto-resistance dependent switching process with non-uniform current density using the proposed framework as an example.

Study on the Reduction Method of Magnetic Noise and Vibration in Home Electric Motors (가전기기용전동기의 전자소음과 진동의 방지대책에 관한 연구)

  • 황영문;조철제
    • 전기의세계
    • /
    • v.26 no.5
    • /
    • pp.74-82
    • /
    • 1977
  • This study is to present a method for reductin of noise and vibration of home electric motors coupled to the mechanical load causing relatively big amplitude of vibration. The noise and vibration factors have been analysed in the divisions such as the pattern related to the armature reaction, the pattern related to the circulating current by induction and the other patterns those are affected by a dditive magnetic field and have an effect on mechanical constants. From the systematic mutual relations between the patterns and daping effects, it is possible to derive the fundamental measure for reduction of noise and vibration. Vibration measurements and analysis were carried out in accordance with the planned experimentation and thre object model was chosen randomly from the production line in a factory where home electric machines were mass-produced. Based on the above-mentioned fundamental measure, suppression effects on noise and vibration have been analysed according to the number of slots, the amount of rotor skew and the way the stator winding connection was series or parallel.

  • PDF

A research of signal analysis using Magntic Inductance Tomography system according to a chance in an object's position and density (Magnetic inductance tomography system을 이용한 대상물체 위치와 밀도 변화 시의 신호해석에 관한 연구)

  • Lee, Sung-Ho;Seo, Kang;Park, Gwan-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.842_843
    • /
    • 2009
  • 본 논문에서는 Magnetic Inductance Tomography System(이하 MIDT System)을 이용하여 대상물체의 위치와 밀도 변화 시의 신호해석에 관한 연구를 하였다. MIDT System은 외부에서 자기장을 인가하고, 인가된 자기장에 의해 변화하는 자기장을 홀센서로 검출한다. MIDT System은 시스템이 간단하고 대상물체에 물리적인 손상을 가하지 않고 측정이 가능하다. 본연구에서는 MIDT System을 직접 구성하여 이론적인 해석신호와 실제 실험을 통한 해석신호의 일치여부를 비교 분석하고 MIDT System을 이용하여 대상물체 위치 변화시의 신호 해석할 수 있는 적합성 여부를 판단하였다.

  • PDF

Quasi-Periodic Oscillation of a Magnetic Cataclysmic Variable, DO Draconis

  • Han, Kiyoung;Kim, Yonggi;Andronov, Ivan L.;Yoon, Joh-Na;Chinarova, Lidia L.
    • Journal of Astronomy and Space Sciences
    • /
    • v.34 no.1
    • /
    • pp.37-44
    • /
    • 2017
  • In this paper, analysis results of the photometric data of DO Dra will be presented. DO Dra had been observed with 1 m LOAO telescope and 0.6 m CBNUO telescope from 2005 through 2014. The data shows kind of periodic oscillation behavior in the orbital period and also in the spin period. It has been found that these QPOs are not observed always and that the periods vary from 30 min to 80 min. We also found that the period variation seems to repeat itself with the period of 13.5 days. It is essential to monitor this object in the future as well as to carry out model calculation in order to have better understanding of these QPO phenomena.