무소음.무진동 스크류 PHC 말뚝공법에 관한 기술적 수준 고찰 (A State of the Art on a Noise & Vibration - Free PHC Screw Pile Method)

  • 하영민;정호영;김영필;김성수;최용규
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 춘계 학술발표회
    • /
    • pp.496-506
    • /
    • 2009
  • Various the low noise & vibration pile methods were developed and used in many construction sites. Low noise & vibration pile methods must be used essentially from the sites where popular complints would be expected. In this paper, low noise & vibration pile methods and screw pile methods were investigated, noise & vibration-free screw PHC pile method, also, was studied and its constructibility and applicability were analyzed.

  • PDF

소음 및 진동 저감을 위한 스크류콘크리트말뚝의 시공 중 소음과 진동 특성에 관한 연구 (A Study on the Noise and Vibration Characteristics during Construction of Screw Concrete Pile for Reduction of Noise and Vibration)

  • 김동철;최용규
    • 한국지반환경공학회 논문집
    • /
    • 제14권9호
    • /
    • pp.21-30
    • /
    • 2013
  • 국내의 소음 진동규제는 점점 더 강화되고 있어 현재의 저소음 저진동공법보다 더 환경친화적인 공법이 필요하게 되었다. 이 연구에서는 소음 및 진동 저감을 위한 스크류콘크리트말뚝공법의 특징에 대하여 설명하였으며 국내 특정 현장에서 시험시공을 실시하고 소음과 진동을 측정하였다. 진동의 경우 측정진동은 7.5m 내에서 진동규제기준을 만족하였다. 소음의 경우 측정소음은 15.0m에서 소음규제기준을 2dB(A) 정도 초과하는 것으로 나타났으나 이는 국내에서 시공되고 있는 기존 저소음 저진동 말뚝공법의 측정치보다 5~20dB(A) 정도 저감된 값이었다.

박막과의 연성에 의한 저주파 소음 저감 (Low frequency noise reduction by coupling with membrane)

  • 박수경;김양한
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1996년도 추계학술대회논문집; 한국과학기술회관, 8 Nov. 1996
    • /
    • pp.148-152
    • /
    • 1996
  • A method of deminishing low frequency noise by acoustic acoupling with compliant wall is described. The coupled governing equations and boundary conditions are derived and solved. The coupled system shows very interesting behavior in the low frequency region; in the low frequency, acoustic wave doesn't propagate, but decay to satisfy the boundary condition with the compliant wall. Henceforth using this mechanism, we propose a method of reducing low frequency noise, which is infact related with the physical properties of compliant wall. The method has been experimentally verified.

  • PDF

민원발생지역에서의 저진동$\cdot$저소음 Granular Pile의 시공사례 (Case History of Low Vibration and Low Noise Granular Pile Method in the Area of Incurred the Popular Enmity)

  • 천병식;김백영
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2003년도 추계학술대회 논문집(II)
    • /
    • pp.176-181
    • /
    • 2003
  • Damages by vibration and noise due to the construction performance are increasing. The rise of construction demand and enlargement of equipments are major reasons of this damage. As a result, the enmity of the people is provoked and this appears to be an obstacle of construction work. Especially, in case of ground improvement construction. Casing pipe is inserted into the Sand Drain, Sand Compaction Pile and Vibrated Crushed-stone Pile by vibration power when carrying out. Hence, a pillar is formed and it creates vibration and noise. This causes a lot of restrictions to construction condition. The low Vibration and low noise construction equipments uses earth auger and hydrulic cylinder for insertion and chopping operation instead of vibro hammer, which is the source of vibration and noise. This minimize ground disturbanceand decrease vibration and noise successfully, but increase chopping effect greatly. Thus, this new equipment is not only suitable for environment but also excellent engineering method of construction.

  • PDF

매입 말뚝공법의 항타공해 저감효과 (A Study on the reduction effect of noise and vibraton using auger-drilled piling)

  • 박찬국;박용부
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1995년도 가을 학술발표회 논문집
    • /
    • pp.1031-1040
    • /
    • 1995
  • Recently, a more strict regulation has become effective on ground vibration and noise induced by construction activities. Consequently the demand for the most widely used method of installing precast piles, i.e. driven piles, is declining. At the same time the demand for low noise and low vibration piling method increased sharply. Currently there are several different low noise and low vibration methods of installing precast piles, mostly preboring method. However, the actual level of ground vibration and noise of these method of construction has not yet been clearly understood. In this paper, through field measurement, suggestion has been made to meet the requirements of the revised regulation.

  • PDF

무소음.무진동 스크류콘크리트말뚝의 시공법 설정 (Determination of Construction Method for Noise & Vibration-Free Screw Concrete Piles)

  • 최용규;김동철;김성수;남문석
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.360-368
    • /
    • 2010
  • Noise and vibration triggered by pile driving in a construction site not only give hard time to the surrounding areas but could also cause residents nearby to file civil complaints to the extent of bringing construction to a halt. To deal with this issue, construction engineers have worked strenuously to develop low noise & low vibration pile methods. A noise & vibration-free screw concrete pile method proposed in this study is one of the successful outputs. It penetrates pile underground by rotating and pressing in body of the pile to avert noise and vibration while maximizing bearing capacity. A prototype of noise and vibration-free precast screw pile method was manufactured, which is not seen anywhere in Korea and elsewhere, and have undergone pilot tests twice to determine construction method.

  • PDF

무소음・무진동을 위한 스크류콘크리트말뚝의 시공법설정에 관한 연구 (A Study on the Determination of Construction Method of Screw Concrete Piles for Noise & Vibration-Free)

  • 최용규;김동철;김성수;남문석
    • 한국지반환경공학회 논문집
    • /
    • 제11권7호
    • /
    • pp.15-24
    • /
    • 2010
  • 말뚝 항타로 인한 소음 진동공해는 건설현장 주변에 피해를 주고 민원을 발생하게 하여 심한 경우에는 공사가 중단되는 사태까지 발생하게 된다. 이를 해결하기 위해 건설 기술자들은 저소음 저진동말뚝공법의 개발을 위해 부단한 노력을 해왔다. 이러한 노력 중의 하나인 무소음 무진동을 위한 스크류콘크리트말뚝공법은 말뚝 본체를 회전 압입시켜 지중에 말뚝을 관입시키는 방법으로 소음과 진동의 발생이 거의 없고 지지력을 극대화 할 수 있는 장점을 가지고 있다. 무소음 무진동을 위한 기성스크류말뚝공법은 국내 외에서 개발되어 있지 않으며 본 연구진에 의해 시제품 제작을 완료하였고 두차례 시험시공을 통하여 시공법을 설정하였다. 본 논문에서는 무소음 무진동을 위한 스크류콘크리트말뚝공법의 특징에 대해 설명하였고 두차례 시험시공 및 이를 통한 시공법 설정에 대하여 설명하였다. 그리고 이러한 시험시공 결과를 토대로 근입깊이와 지반조건에 따라 스크류콘크리트말뚝을 지중에 관입시키는 시공방법에 관한 연구를 수행하였다.

낮은 상관 관계를 갖는 자동차 공력 소음에 대한 음향 홀로그래피 (Application of Acoustic Holography to Automobile Aeroacoustic Noise of Low Coherence)

  • 남경욱;김양한
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.561-564
    • /
    • 2004
  • Acoustic holography is applied to automobile aeroacoustic noise. Automobile aeroacoustic noise has low coherence due to multiple independent sources and measurement noise. This paper discusses the reliability of acoustic holography on this low coherence condition. Main subjects are the number and position of reference microphones, which is used for a step-by-step scanning method, and measurement noise. A real automobile experiment verifies the results.

  • PDF

저진동 파일시공법에 따른 지반진동 응답 예측을 위한 실험적 연구 (Experimental Study for Prediction of Ground Vibration Responses by the Low-vibration Pile Driving Methods)

  • 강성후;정석규;박선준
    • 한국소음진동공학회논문집
    • /
    • 제21권4호
    • /
    • pp.299-306
    • /
    • 2011
  • This study investigated the SIP-method as a low-vibration, low-noise engineering method. The ground vibrations caused by the SIP-method were measured and analyzed in each step. From the analysis results, quantitative ground vibration values and reliable vibration estimation equations were proposed. Furthermore, the ground vibrations caused by the SIP-method were compared with the ground vibrations caused by other methods presented by existing studies. Based on the vibration estimation equation with 50 % reliability, the ground vibration values by the SIP-method at the distance of 10~150 m corresponded to 17~57 % of the ground vibration values by the equation proposed by Attewell & Famer, and 14~96 % of the ground vibration values by the equation proposed by Prof. Park in his study using a diesel drop hammer. These results showed that the ground vibration reduction effect of the SIP-method was higher those of other general engineering methods. Finally, the permissible scope of work using the SIP-method which meets the domestic vibration standards was presented.

저진동 파일시공법에 따른 지반진동 응답 예측을 위한 실험적 연구 (Experimental Study for Prediction of Ground Vibration Responses by the Low-Vibration Pile Driving Methods)

  • 강성후;박선준;정석규
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2010년도 추계학술대회 논문집
    • /
    • pp.201-207
    • /
    • 2010
  • In this study, the SIP (Soil-cement Injected precast Pile) method among the Low-vibration & Low-noise pile driving methods was decided into study compensation. Ground vibrations by the SIP methods step by step divide and were analyzed. Quantitative response values and ground vibration equations with reliability were presented from findings of this study. Also, vibration responses that are occurred by the SIP method of construction were compared as quantitative with vibration responses by general method of construction that are presented in existent study. Ground vibration values by the SIP method correspond to level of 17 ~ 57% of values that are assumed by the Attewell & Famer's equation, respectively, and these result compares in reliability 50% and separated distance 10 ~ 50 m. Also, those values were analyzed that correspond to level of 14 ~ 96% of ground vibration values by the Prof. Park's equation, respectively. Construction limit extents, separation distances from vibration occurs position, were presented that can satisfy domestic criteria for vibration control for the SIP methods. Those presented in this paper were divided newly according to reliability.

  • PDF