• Title/Summary/Keyword: Loss Analysis

Search Result 8,482, Processing Time 0.036 seconds

Stability Analysis of Networked Control System with Time Delay and Data Loss (시간 지연과 데이터 손실을 고려한 네트워크 제어시스템의 안정도 분석)

  • Jung Joonhong;Choi Sooyoung;Park Kiheon
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.53 no.10
    • /
    • pp.678-689
    • /
    • 2004
  • The major concern of networked control system is network uncertainties such as time delay and data loss. Because these uncertainties may degrade the performance of networked control system and destabilize the entire system. Therefore, the performance and the stability variation of networked control system due to network uncertainties must be considered first in designing networked control system. In particular, the stability analysis of networked control system is most important issue since time delay and data loss can make the overall systems unstable. In this paper, we present a new stability analysis method of networked control system with time delay and data loss, which is impossible in previous works. The proposed method can determine maximum time delay and allowable transmission rate that preserve stability performance of networked control system. The results of the simulation validate effectiveness of our stability analysis method.

Evaluation of health screening data for factors associated with peri-implant bone loss

  • Hyunjong Yoo;Jun-Beom Park;Youngkyung Ko
    • Journal of Periodontal and Implant Science
    • /
    • v.52 no.6
    • /
    • pp.509-521
    • /
    • 2022
  • Purpose: Systemic health has a profound effect on dental treatment. The aim of this study was to evaluate peri-implant bone loss and health screening data to discover factors that may influence peri-implant diseases. Methods: This study analyzed the panoramic X-rays of patients undergoing health screenings at the Health Promotion Center at Seoul St. Mary's Hospital in 2018, to investigate the relationship between laboratory test results and dental data. The patients' physical data, such as height, weight, blood pressure, hematological and urine analysis data, smoking habits, number of remaining teeth, alveolar bone level, number of implants, and degree of bone loss around the implant, were analyzed for correlations. Their associations with glycated hemoglobin, glucose, blood urea nitrogen (BUN), creatinine, and severity of periodontitis were evaluated using univariate and multivariate regression analysis. Results: In total, 2,264 patients opted in for dental health examinations, of whom 752 (33.2%) had undergone dental implant treatment. These 752 patients had a total of 2,658 implants, and 129 (17.1%) had 1 or more implants with peri-implant bone loss of 2 mm or more. The number of these implants was 204 (7%). Body mass index and smoking were not correlated with peri-implant bone loss. Stepwise multivariate regression analysis revealed that the severity of periodontal bone loss (moderate bone loss: odds ratio [OR], 3.154; 95% confidence interval [CI], 1.175-8.475 and severe bone loss: OR, 7.751; 95% CI, 3.003-20) and BUN (OR, 1.082; 95% CI, 1.027-1.141) showed statistically significant predictive value. The severity of periodontitis showed greater predictive value than the biochemical parameters of blood glucose, renal function, and liver function. Conclusions: The results of this study showed that periodontal bone loss was a predictor of peri-implant bone loss, suggesting that periodontal disease should be controlled before dental treatment. Diligent maintenance care is recommended for patients with moderate to severe periodontal bone loss.

Analysis of transport current loss in HTS tape (고온 초전도 선재에서의 통전 손실 해석)

  • 최세용;이준호;나완수;장석헌;주진호;정재훈;류경우
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.02a
    • /
    • pp.55-57
    • /
    • 2003
  • In this paper, we described the procedures of AC transport current loss in HTS tape. To carry out the calculation, A-$\Phi$ formulation was introduced and two dimensional FEM was used for computation. The results were showed that ellipse shape was higher loss compared to rectangle one and these were almost same behavior of analytical results predicted by Norris. A comparative analysis of loss for various n-value variation was also presented.

  • PDF

Analysis of the Plane-Concave Fabry-Perot cavity for a tunable filter (파장가변 필터를 위한 Plane-Concave Fabry-Perot 공진기의 해석)

  • Yeh YunHae
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.6
    • /
    • pp.495-502
    • /
    • 2004
  • We proposed an analysis model for a Fabry-Perot cavity constructed with a plane-mirrored optical fiber and a concave-mirrored one. We presented the analysis results calculated by inserting practical values into the equations derived. The coupling loss of the cavity and the mirror loss are the most important parameters in reducing the insertion loss of the filter. In order to build a filter of finesse 600, FSR 57 nm, and insertion loss < 3 dB, the plane-concave cavity using mirrors of loss < 0.09% should be aligned for the coupling loss to be less than 0.1 %.

Calculation of Iron Loss under Rotational Magnetic Field Using Finite Element Method (회전 자계에 의한 철손의 유한요소 해석)

  • Lee, H.Y.;Park, G.S.;Hahn, S.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.147-149
    • /
    • 1994
  • In designing high efficiency electrical machines, calculation of iron loss is very important. And it is reported that in the induction motor and in the T-joint of 3 phase transformer, there occurred rotational magnetic field and much iron loss is generated owing to this field. In this paper, rotational power loss in the electrical machine under rotational magnetic field is discussed. Until now, loss analysis is based on the magnetic properties under alternating field. And with this one dimensional magnetic propertis, it is difficult to express iron loss under rotational field. In this paper, we used two dimensional magnetic property data for the numerical calculation of rotational power loss. We used finite element method for calculation and the analysis model is two dimensional magnetic property measurement system. We used permeability tensor instead of scalar permeability to present two dimensional magnetic properties. And in this case, we cannot uniquely define energy functional because of the asymmetry of the permeability tensor, so Galerkin method is used for finite element analysis.

  • PDF

A Study on the Environmental Factors affecting Child Loss through Correlation Analysis between Child Loss and Pedestrian Density in Large-scale Parks - Focused on Busan Citizens Park and Dream Forest - (대규모 공원에서의 미아발생과 보행밀도와의 상관분석을 통한 미아발생 환경요인 도출 - 부산시민공원과 북서울 꿈의 숲을 중심으로 -)

  • Choi, Soyoung;Choi, Jaepil
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.36 no.5
    • /
    • pp.59-70
    • /
    • 2020
  • The purpose of this study is to derive the environmental factors affecting child loss through correlation analysis between child loss and pedestrian density. The status of lost children was identified through the lost child records and interviews in large parks. In addition, the behavior survey was conducted by photographing the entire outdoor of each park, and visitors was marked on the behavioral maps. Also, the pedestrian density was analyzed by GIS as 100㎡ and 1㎡ grid. As a result, child loss was related to the pedestrian density rather than the number of visitors or the area. Especially, 'Dynamic pedestrian density' and 'Ratio of pedestrian in high density to area' was related to child loss. In other words, the more dynamic behaviors such as play and movement appear, and the more the local area of high density, the higher the probability of child loss. In addition, environmental factors that induce such high density include bottlenecks, overlap of circulation due to multi-functionality of space, concentration of rides, and concentration of guardians due to visual obstacles.

A SEA Modeling of a compact car and Interior Noise Analysis (소형 승용차량의 SEA 모델링 및 내부 소음 연구)

  • Kim, Sang-Su;Kim, Kwan-Ju;Lim, Hyo-Suk;Kim, Young-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.824-828
    • /
    • 2007
  • In this paper Statistical Energy Analysis has been considered to predict middle, high frequency air borne interior noise. PIM method is used for verification. Damping loss factor and coupling loss factor have been derived from the response(SPL) of sub systems when the power is applied. The airborne SEA model of vehicle is modeled through AutoSea2. Insulation material's absorption coefficient and transmission loss are acquired from closed form solution and experiment.

  • PDF

On the Transmission Loss Measurement System (전달손실계수 측정 시스템에 대하여)

  • Ryu, Yun-Seon;Kim, Yoon-Seok;Callec, Philippe
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.166-171
    • /
    • 2002
  • The transmission loss coefficient is very important acoustic property in parallel with absorption and acoustic impedance categorizing the acoustical materials, which can control the acoustical problems. At the same time, the transmission loss coefficient is a key parameter to choose the optimum material for the analysis of acoustical characteristics of material using SEA(Statistical Energy Analysis). In this paper, the transmission loss coefficient measurement system using 4-microphone impedance tube is proposed, based on the idea calculating the full transfer matrix of the acoustical sample to test. The theoretical background and measurement system are introduced, and finally the measurement results are verified.

  • PDF

Analytical Model Improvement of Automotive Muffler using the Experimental Results of Transmission Loss (투과손실 실험결과를 이용한 자동차용 소음기의 해석모델 개선)

  • Jung, Jin-Nyon;Kim, Won-Jin
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.9
    • /
    • pp.204-209
    • /
    • 2001
  • The finite element model for automotive muffler analysis is improved by modifying the boundary condition of outlet and the mesh of finite element model. The model minimizes the difference between transmission loss from analysis and that from experiment. Four different boundary conditions and the four types of finite element model are tested to find out the best one of those. From the case study it is verified that the bevel of transmission loss can be changed by the variation of radiation impedance value. Also the resonance or anti-resonance frequencies of transmission loss can be shifted by the variation of finite element mesh. An improved finite element model of muffler is proposed in consideration with the accuracy and the computing time of analysis.

  • PDF

Performance analysis of mixed-flow fans considering the low flow characteristics (저유량 특성을 고려한 사류 송풍기의 성능 해석)

  • Oh, Hyoung Woo;Kim, Kwang-Yong
    • 유체기계공업학회:학술대회논문집
    • /
    • 2000.12a
    • /
    • pp.110-115
    • /
    • 2000
  • The mean streamline analysis using the empirical loss correlations has been developed for performance prediction of industrial mixed-flow fan impellers in the present study. New simple, but effective, models for the additional Euler input work characteristic and an internal recirculation loss due to internal flow reversal under the low flowrate conditions are proposed in this paper. Comparison of overall performance predictions with six sets of test data of mixed-flow fans is accomplished to demonstrate the accuracy of the proposed models. Predicted performance curves by the present set of loss models agree fairly well with experimental data for a variety of mixed-flow fan impellers over the entire operating conditions. The prediction method presented herein can be used efficiently in the conceptual design phase of mixed-flow fan impellers.

  • PDF