• 제목/요약/키워드: Loading tests

Search Result 2,323, Processing Time 0.027 seconds

Experimental investigation of the effects of pipe location on the bearing capacity

  • Bildik, Selcuk;Laman, Mustafa
    • Geomechanics and Engineering
    • /
    • v.8 no.2
    • /
    • pp.221-235
    • /
    • 2015
  • A series of laboratory model tests were conducted to investigate the effects of buried pipes location on the bearing capacity of strip footing in cohesionless soil. The variables examined in the testing program include relative density of the sand, loading rate of tests, burial depths of pipe and horizontal distance of pipe to footing. The test results showed a significant increase in bearing capacities when embedment ratio of pipe and horizontal distance of pipe to footing were increased. Based on the test results, it can be concluded that the location of pipes and relative density of sand are main parameters that affect the bearing capacity of strip footing. However, loading rate has not considerable effect on bearing capacity.

Settlement Characteristics of Short-fiber Reinforced Soil under Simulated Railroad Loading (열차모의하중에 대한 단섬유 보강토체의 침하특성)

  • 박영곤;김정기;김현기;황선근
    • Proceedings of the KSR Conference
    • /
    • 2002.10a
    • /
    • pp.596-600
    • /
    • 2002
  • To analyze the settlement characteristics of short-fiber reinforced soil(SFRS), which will be used as a new backfill material of reinforced retaining wall, under simulated railroad loading, a series of tests with loading condition of 5 Hz frequency and 500,000 cycles were performed. The materials used for tests are soils with SM or ML type, and polypropylene short-fibers with mono-filament(PPM) or fibrillated type(PPF). From the tests, average plastic settlement is low at PPF38(0.3%)(abbreviation of PPF with 38mm length and mixing ratio 0.3%), PPF38(0.5%), PPM60(0.2%) for SFRS using SM soil and at PPF38(0.3%), PPF60(0.2%) for SFRS using ML soil. Elastic settlement is low at PPM60(0.2%) for SFRS using SM soil and at PPM60(0.5%) for SFRS using ML soil.

  • PDF

A Basic Study on the Geobag System for Urgent Restoration of the Collapsed Roadbed (강우로 유실된 철도노반 긴급복구를 위한 지오백시스템 개발 기초연구)

  • 조삼덕;황선근;이대영;이광우
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.2
    • /
    • pp.255-265
    • /
    • 2003
  • A series of laboratory tests were performed to evaluate engineering properties of geobag system which is used for urgent restoration of the collapsed roadbed. In this study, the suitable geobag size was proposed as 44cm wide and 66cm long, and the suitable filling ratio of geobag was also proposed as 80% through the static loading tests. Also a series of model tests were carried out to investigate the characteristics of the engineering behavior and the distribution of earth pressure of the geobag roadbed under static and dynamic loading.

The behavior of high-speed rail roadbed reinforced by geogrid under cyclic loading (지오그리드로 보강한 고속철도 노반의 동적 거동)

  • 신은철;김두환;김종인
    • Proceedings of the KSR Conference
    • /
    • 1999.11a
    • /
    • pp.415-422
    • /
    • 1999
  • The general concept of reinforced roadbed in the high-speed railway is to cope with the soft ground for the bearing capacity and settlement of foundation soil. The cyclic plate load tests were performed to determine the behavior of reinforced ground with multiple layers of geogrid underlying by soft soil. Five series of test were conducted with varying the soil profile conditions including the ground level, type of soil, and the thickness of each soil layer. Based on these plate load tests, laboratory model tests under cyclic loading were conducted to know the effect of geogrid reinforcement in particular for the high-speed rail roadbed. The permanent settlement and the behavior of earth pressure in reinforced roadbed subjected to a combination of static and dynamic loading are presented.

  • PDF

Prediction of Crack Growth in 2124-7851 Al-Alloy Under Flight-Simulation Loading (비행하중하에서 2124-T851 알루미늄합금의 피로균열진전 예측)

  • Sim, Dong-Seok;Hwang, Don-Yeong;Kim, Jeong-Gyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.8
    • /
    • pp.1487-1494
    • /
    • 2002
  • In this study, to propose the prediction method of the crack growth under flight-simulation loading, crack growth tests are conducted on 2124-7851 aluminum alloy specimens. The prediction of crack growth under flight-simulation loading is performed by the stochastic crack growth model which was developed in previous study. First of all, to reduce the complex load history into a number of constant amplitude events, rainflow counting is applied to the flight-simulation loading wave. The crack growth, then, is predicted by the stochastic crack growth model that can describe the load interaction effect as well as the variability in crack growth process. The material constants required in this model are obtained from crack growth tests under constant amplitude loading and single tensile overload. The curves predicted by the proposed model well describe the crack growth behavior under flight-simulation loading and agree with experimental data. In addition, this model well predicts the variability of fatigue lives.

Fatigue Life Prediction for High Strength AI-alloy under Variable Amplitude Loading (변동하중하에서 고강도 알루미늄 합금의 피로수명 예측)

  • Sim, Dong-Seok;Kim, Gang-Beom;Kim, Jeong-Gyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.8 s.179
    • /
    • pp.2074-2082
    • /
    • 2000
  • In this study, to investigate and to predict the crack growth behavior under variable amplitude loading, crack growth tests are conducted on 7075-T6 aluminum alloy. The loading wave forms are generated by normal random number generator. All wave forms have same average and RMS(root mean square) value, but different standard deviation, which is to vary the maximum load in each wave. The modified Forman's equation is used as crack growth equation. Using the retardation coefficient D defined in previous study, the load interaction effect is considered. The variability in crack growth process is described by the random variable Z which was obtained from crack growth tests under constant amplitude loading in previous work. From these, a statistical model is developed. The curves predicted by the proposed model well describe the crack growth behavior under variable amplitude loading and agree with experimental data. In addition, this model well predicts the variability in crack growth process under variable amplitude loading.

Damage and fatigue quantification of RC structures

  • Sadeghi, Kabir;Nouban, Fatemeh
    • Structural Engineering and Mechanics
    • /
    • v.58 no.6
    • /
    • pp.1021-1044
    • /
    • 2016
  • Different versions of a damage index (DI) along with a formulation to find the number of cycles at failure due to fatigue, applicable to reinforced concrete (RC) structures are presented. These are based on an energetic analysis method and applicable to both global and local levels. The required data can be found either from the numerical simulation of structures or from the experimental tests. A computer program has been developed to simulate numerically the nonlinear behavior of RC columns under cyclic loading. The proposed DI gives a regular distribution of structural damages up to failure and is validated by the results of the tests carried out on RC columns subjected to cyclic loading. In general, the local and global damage indices give approximately similar results, while each of them has its own advantages. The advantage of the implicit version of DI is that, it allows the comparison of the results with those of the monotonic loading case, while the explicit version makes it possible to estimate the number of loading cycles at failure due to fatigue, and the advantage of the simplified version is that; the monotonic loading data is not needed for the cyclic loading case.

Comparison of Lateral Pile Behavior under Static and Dynamic Loading by Centrifuge Tests (원심모형 실험을 이용한 지반-말뚝 상호작용의 정적 및 동적 거동 평가)

  • Yoo, Min-Taek;Kwon, Sun-Yong
    • Journal of the Korean Geotechnical Society
    • /
    • v.34 no.7
    • /
    • pp.51-58
    • /
    • 2018
  • In this study a series of centrifuge tests were carried out in dry sand to analyze the comparison of lateral pile behavior for static loading and dynamic loading condition. In case of static loading condition, the lateral displacement was applied up to 50% of pile diameter by deflection control method. And the input sine wave of 0.1 g~0.4 g amplitude and 1 Hz frequency was applied at the base of the soil box using shaking table for dynamic loading condition. From comparison of experimental static p-y curve obtained from static loading tests with API p-y curves, API p-y curves can predict well within 20% error the ultimate subgrade reaction force of static loading condition. The ultimate subgrade reaction force of experimental dynamic p-y curve is 5 times larger than that of API p-y curves and experimental static p-y curves. Therefore, pseudo-static analysis applied to existing p-y curve for seismic design could greatly underestimate the soil resistance at non-linear domain and cause overly conservative design.

A Feasibility Study of Loading Test for Safety Assessment : Concrete Bridges (재하시험 수행에 관한 적정성 연구 : 콘크리트 교량)

  • Hwang, Jin Ha;An, Seoung Su;Kim, Ju Han
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.6
    • /
    • pp.147-155
    • /
    • 2011
  • The bridges where serious damages, defects, material degradations, etc. are not found can be presumed to have enough safety for the specified design loads, nevertheless, in many cases the loading carrying capacity is rated through loading tests. The safety specifications and manuals get no further than qualitative instructions for performing loading test or not. Some studies presented the improved appraisal methods for determining the load carrying capacity; however, the feasibility studies for loading test are scarcely carried out. This study examines an existing question, whether the loading tests are necessarily required in the safety assessment or not, and suggests an alternative for that via a statistical analysis for dozens of condition evaluation reports for concrete bridges.

Experimental Investigation on the Energy Dissipation of Friction-type Reinforcing Members Installed in a Transmission Tower for Wind Response Reduction (송전철탑의 풍응답 감소를 위한 마찰형 보강기구의 에너지 소산특성 분석 실험)

  • Park, Ji-Hun;Moon, Byoung-Wook;Lee, Sung-Kyung;Min, Kyung-Won
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.7 s.124
    • /
    • pp.649-661
    • /
    • 2007
  • Friction-type reinforcing members(FRM) to enhance the resistance to wind loads of a transmission tower through both stiffness strengthening and damping increase are energy dissipation devices that utilize bending deflection of a tower leg. In this paper, the hysteretic behavior of the transmission tower structure with FRMs was experimentally investigated through cyclic loading tests on a half scale substructure model. Firstly, the variation of friction forces and durability of the FRM depending on the type of friction-inducing materials used in the FRM were examined by performing the cyclic loading tests on the FRM. Secondly, cyclic loading tests of a half-scale two-dimensional substructure model of a transmission tower with FRMs were conducted. Test results show that the FRM, of which desired maximum friction force is easily regulated by adjusting the amplitude of the torque applied to the bolts, have stable hysteretic behaviors and it is found that there exists the optimum torque depending on a design load by investigating the amount of energy dissipation of the FRMs according to the increase of torque.