• Title/Summary/Keyword: Load-modulation

Search Result 326, Processing Time 0.029 seconds

Current Regulated Delta Modulator for Series Resonant Inverter with Transformer-Coupled Load (변압기-결합형 직렬공진 인버터의 델타변조 전류제어)

  • 안희욱;김학성
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.3
    • /
    • pp.231-239
    • /
    • 1999
  • An improved version of current-regulated delta modulator (CRDM) is investigated for the output cunent control of v voltage-source inverters that have transformer-coupled series resonant load and are operated at the resonant frequency. Conventional CRDM has not only CUlTent offset problem but also transformer flux saturation problem when i it is applied to induction heating systems that have transformel-coupled loads. To cope with these problems, the effect of flux saturation is analysed, and simple method to av이d the problem is proposed. And integral type of CRDM is a adopted to remove the cunent offset. The boundaries of integrator gain for stable operation is calculated using the c concept of sliding mode controL The validity of proposed strategy is vel퍼ed through simulations and prototype e experiments.

  • PDF

The Development of High-Current Power Supply System for Electrolytic Copper Foil

  • Luo, An;Ma, Fujun;Xiong, Qiaopo;He, Zhixing
    • Journal of Power Electronics
    • /
    • v.15 no.2
    • /
    • pp.399-410
    • /
    • 2015
  • A 6.5 V/50 kA high-frequency switching power supply (HSPS) system composed of 10 power modules is developed to meet the requirements of copper-foil electrolysis. The power module is composed of a two-leg pulse width modulation (PWM) rectifier and a DC/DC converter. The DC/DC converter adopts two full-wave rectifiers in parallel to enhance the output. For the two-leg PWM rectifier, the ripple of the DC-link voltage is derived. A composite control method with a ripple filter is then proposed to effectively improve the performance of the rectifier. To meet the process demand of copper-foil electrolysis, the virtual impedance-based current-sharing control method with load current full feedforward is proposed for n-parallel DC/DC converters. The roles of load current feedforward and virtual impedance are analyzed, and the current-sharing control model of the HSPS system is derived. Virtual impedance is used to adjust the current-sharing impedance without changing the equivalent output impedance, which can effectively reduce current-sharing errors. Finally, simulation and experimental results verify the structure and control method.

A Study on the Power Converter Control of Utility Interactive Photovoltaic Generation System (계통 연계형 태양광 발전시스템의 전력변환기 제어에 관한 연구)

  • Na, Seung-Kwon;Ku, Gi-Jun;Kim, Gye-Kuk
    • Journal of the Korea Society of Computer and Information
    • /
    • v.14 no.2
    • /
    • pp.157-168
    • /
    • 2009
  • In this paper, a photovoltaic system is designed with a step up chopper and single phase PWM(Pulse Width Modulation) voltage source inverter. Where proposed Synchronous signal and control signal was processed by one-chip microprocessor for stable modulation. The step up chopper operates in continuous mode by adjusting the duty ratio so that the photovoltaic system tracks the maximum power point of solar cell without any influence on the variation of insolation and temperature because solar cell has typical voltage and current dropping character. The single phase PWM voltage source the inverter using inverter consists of complex type of electric power converter to compensate for the defect, that is, solar cell cannot be developed continuously by connecting with the source of electric power for ordinary use. It can cause the effect of saving electric power. from 10 to 20[%]. The single phase PWM voltage source inverter operates in situation that its output voltage is in same phase with the utility voltage. In order to enhance the efficiency of photovoltaic cells, photovoltaic positioning system using sensor and microprocessor was design so that the fixed type of photovoltaic cells and photovoltaic positioning system were compared. In result, photovoltaic positioning system can improved 5% than fixed type of photovoltaic cells. In addition, I connected extra power to the system through operating the system voltage and inverter power in a synchronized way by extracting the system voltage so that the phase of the system and the phase of single-phase inverter of PWM voltage type can be synchronized. And, It controlled in order to provide stable pier to the load and the system through maintaining high lurer factor and low output power of harmonics.

A Study On High Power Factor Sine Pulse Type Power Supply For Atmospheric Pressure Plasma Cleaning System with 3-Phase PFC Boost Converter (3상 PFC 부스트 컨버터를 채용한 상압플라즈마 세정기용 고역률 정형파 펄스 출력형 전원장치에 관한 연구)

  • Han, Hee-Min;Kim, Min-Young;Seo, Kwang-Duk;Kim, Joohn-Sheok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.1
    • /
    • pp.72-81
    • /
    • 2009
  • This paper presents quasi-resonant type high power factor ac power supply for atmospheric pressure plasma cleaning system adopting three phase PFC boost converter and it's control method. The presented ac power supply consists of single phase H-bridge inverter, step-up transformer for generating high voltage and three phase PFC boost converter for high power factor on source utility. Unlikely to the traditional LC resonant converter, the propose one has an inductor inside only. A single resonant takes place through the inside inductor and the capacitor from the plasma load modeled into two series capacitor and one resistance. The quasi-resonant can be achieved by cutting the switching signal when the load current decrease to zero. To obtain power control ability, the propose converter controlled by two control schemes. One is the changing output pulse period scheme in the manner of PFM(Pulse Frequency Modulation) control. On the other, to provide more higher power to load, the DC rail voltage is directly controlled by the 3-phase PFC boost converter. The significant merits of the proposed converter are the uniform power providing capability for high quality plasma generation and low reactive power in AC and DC side. The proposed work is verified through digital simulation and experimental implementation.

Superheat Control of an Inverter-driven Heat Pump Using PI Control Algorithm

  • Park, Jong-Min;Kim, Yong-Chan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.10 no.2
    • /
    • pp.106-115
    • /
    • 2002
  • The performance of an inverter-driven water-to-water heat pump with an electronic expansion valve (EEV) was measured as a function of compressor frequency, load conditions, and EEV opening. Based on the test results, a controller using proportional integral (PI) feedback or PI feedforward algorithm was designed and tested to investigate capacity modulation and transient response control of the system. Although the relation between superheat and EEV opening of the heat pump showed nonlinear characteristics, a control gain obtained at the rated frequency was applicable to various operating conditions without causing large deviations. When the simple PI feedback control algorithm was applied, a large overshoot of superheat and wet compression were observed due to time delay effects of compressor frequency. However, applying PI feedforward control scheme yielded better system performance and higher reliability, compared to the PI feedback algorithm.

A novel controller for switching audio power amplifier with digital input (디지털 PWM 입력 D급 음향 증폭기를 위한 새로운 제어기법)

  • Park, Jong-Hu;Kim, C.G.;Cho, B.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.976-979
    • /
    • 2002
  • A new controller for switching audio power amplifier with digital PWM input is proposed- Bi-directional Saw-tooth Error Correction (BSEC). This control method for high quality switching amplifier is based on a pulsed edge correction approach using PWM audio signal input as a reference of power switching digital to analog converter. The proposed controller has excellent features such as wide error correction range and no limitation on the modulation index. The controller is implemented in the half-bridge class D amplifier and the performance is verified through hardware experiments. It delivers 100W into 4${\Omega}$ load with less than 0.2% of total harmonic distortion (THD) all over operating range and an maximum efficiency of 82%.

  • PDF

A study on Active Power Filter Available for DC-Link Boost and Power Factor Control (DC전압 충전 및 전원 역률 보상이 가능한 APF에 관한 연구)

  • Lee, Woo-Cheol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.1
    • /
    • pp.53-60
    • /
    • 2013
  • In this paper, a control algorithm for active power filter (APF), which compensates for the harmonics and power factor, boosting the DC-link voltage is proposed. The proposed scheme employs a pulse-width-modulation (PWM) voltage-source inverter. A simple algorithm to detect the load current harmonics is also proposed. The APF and charging circuit are implemented in one inverter system. Finally, the validity of the proposed scheme is investigated with simulated and experimental results for a prototype APF system rated at 3kVA.

ART2 Neural Network Applications for Diagnosis of Sensor Fault in the Indoor Gas Monitoring System

  • Lee, In-Soo;Cho, Jung-Hwan;Shim, Chang-Hyun;Lee, Duk-Dong;Jeon, Gi-Joon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1727-1731
    • /
    • 2004
  • We propose an ART2 neural network-based fault diagnosis method to diagnose of sensor in the gas monitoring system. In the proposed method, using thermal modulation of operating temperature of sensor, the signal patterns are extracted from the voltage of load resistance. Also, fault classifier by ART2 NN (adaptive resonance theory 2 neural network) with uneven vigilance parameters is used for fault isolation. The performances of the proposed fault diagnosis method are shown by simulation results using real data obtained from the gas monitoring system.

  • PDF

Dynamic Investigation of the Brushless DC Motor

  • Sirilappanich, Surachet;Somchaiwong, Nitipong;Pongswatd, Sawai;Ukakimapurn, Prapart
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1867-1870
    • /
    • 2003
  • The analysis and simulation are the method to study the behavior, response, and specification of the driver device. This paper proposes brushless DC drive which using the vector control technique. The encoder is used detect the rotor position and decode to Three-phase step signal. The step signal is modulated with triangle signal and change to the pulse width modulation (PWM) signal. The PWM signal is used for control the input power of the motor based on the vector control technique. The experimental results of the driver circuit and motor response performed under the following condition: as the motor was started, change the load torque, and vary the supply voltage. The experimental performs with a dynamometer and the test results are compared to the simulation method is the same result.

  • PDF

An Embedded system for real time gas monitoring using an ART2 neural network

  • Cho, Jung-Hwan;Shim, Chang-Hyun;Lee, In-Soo;Lee, Duk-Dong;Jeon, Gi-Joon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.479-482
    • /
    • 2003
  • We propose a real time gas monitoring system for classifying various gases with different concentrations. Using thermal modulation of operating temperature of two sensors, we extract patterns of gases from the voltage across the load resistance. We adopt the relative resistance as a pre-processing method and an ART2 neural network as a pattern recognition method. The proposed method has been implemented in a real time embedded system with tin oxide gas sensors, TGS 2611, 2602 and an MSP430 ultra-low power microcontroller in the test chamber.

  • PDF