Browse > Article
http://dx.doi.org/10.5207/JIEIE.2013.27.1.053

A study on Active Power Filter Available for DC-Link Boost and Power Factor Control  

Lee, Woo-Cheol (Hankyong National University Dept. of Electrical Electronic & Control Engineering/Institute for information technology convergence)
Publication Information
Journal of the Korean Institute of Illuminating and Electrical Installation Engineers / v.27, no.1, 2013 , pp. 53-60 More about this Journal
Abstract
In this paper, a control algorithm for active power filter (APF), which compensates for the harmonics and power factor, boosting the DC-link voltage is proposed. The proposed scheme employs a pulse-width-modulation (PWM) voltage-source inverter. A simple algorithm to detect the load current harmonics is also proposed. The APF and charging circuit are implemented in one inverter system. Finally, the validity of the proposed scheme is investigated with simulated and experimental results for a prototype APF system rated at 3kVA.
Keywords
APF; compensation; harmonics; charging circuit;
Citations & Related Records
연도 인용수 순위
  • Reference
1 S. Bhattacharya and D.M.Divan, "Synchronous frame based controller implementation for a hybrid series active filter system," IEEE IAS Ann. Mtg, pp. 2531-2540, 1995.
2 Koval, D.O., Bocancea, R.A., Kai Yao, Hughes, M.B. "Canadian national power quality survey: frequency and duration of voltage sags and surges at industrial sites", IEEE Transactions on Industry Applications, Vol. 34, Issue: 5, pp. 904-910, Sept.-Oct. 1998.   DOI   ScienceOn
3 Xiaoming Yuan, Me, W. Stemmler, H and Allmeling, J., "Stationary-frame generalized integrators for current control of active power filters with zero steady-state error for current harmonics of concern under unbalanced and distored operation conditions", IEEE Transactions on Industry Applications, Vol. 38, pp. 523-532, 2002.   DOI   ScienceOn
4 L. Mohan, J. W. Dixon, R. R. Wallace, ""A Three-phase Active power Filter Operation With Fixed Switching Frequency for Reactive Power and Current Harmonic Compensation,"" IEEE Trans. Indus. Appli, Vol. 42, No. 4, pp. 402-408, 1995.   DOI   ScienceOn
5 W. Lee, D. Lee, T. Lee, "New control scheme for a unified power quality compensator-Q with minimum active power injection," IEEE Trans. on Power Delivery, Vol.25, No.2, pp.1068-1076, Apr. 2010.   DOI   ScienceOn
6 C. Zhan, V. Ramachandaramurthy, A. Arulampalam, C. Fitzer, S. Kromlidis,M. Bames, N. Jenkins, "Dynamic voltage restorer based on voltage space vector PWM control," IEEE Trans. on Industry Applications, Vol.37, No.6, pp.1855-1863, Nov./Dec. 2001.   DOI   ScienceOn
7 S. Lee, T. Vu, H. Cha, "A new fast peak detector for single or three-phase unsymmetrical voltage sags," in Proc .IEEE-ECCE Conf., pp. 434-440, 2010.
8 Z. Yao, L Xiao, "Seamless transfer of single-phase grid-interactive inverters between grid-connected and stand-alone modes," IEEE Transactionson Power Electronics, Vol.25, No.6, pp.1597-1603, 2010.   DOI   ScienceOn
9 F. D. Freijedo, J. Doval-Gandoy, O. Lopez, P. Fernandez-Comesana, C. Martinez-Penalver, "A signalprocessing adaptive algorithm for selective current harmonic cancellation in active power filter," IEEE Trans. on Industrial Electronics, Vol. 56, No. 8, pp. 2829-2840, August 2009.   DOI   ScienceOn