• Title/Summary/Keyword: Lim Gyu

Search Result 1,212, Processing Time 0.027 seconds

Metastasis prognostic factors and cancer stem cell-related transcription factors associated with metastasis induction in canine metastatic mammary gland tumors

  • Kim, Saetbyul;Bok, Eunyeong;Lee, Sangyeob;Lee, Hyeon-Jeong;Choe, Yongho;Kim, Na-Hyun;Lee, Won-Jae;Rho, Gyu-Jin;Lee, Sung-Lim
    • Journal of Veterinary Science
    • /
    • v.22 no.5
    • /
    • pp.62.1-62.13
    • /
    • 2021
  • Background: Canine mammary gland tumor (MGT) is the most common cancer in aged female dogs. Although it's important to identify reliable metastasis or prognostic factors by evaluating related to cell division, adhesion, and cancer stem cell-related transcription factor (TF) in metastasis-induced canine MGT, but there are limited studies. Objectives: We aimed to identify metastasis prognostic factors and cancer stem cell-TFs in canine MGTs. Methods: Age-matched female dogs diagnosed with MGT only were classified into metastatic and non-metastatic groups by histopathological staining of MGT tissues. The mRNA levels of cancer prognostic metastasis molecular factors (E-cadherin, ICAM-1, PRR14, VEGF, HPRT1, RPL4 and hnRNP H) and cancer stem cell-related TFs (Oct4, Sox2, and Nanog) were compared between metastatic and non-metastatic canine MGT tissues using qRT-PCR analysis. Results: The mRNA levels of ICAM-1, PRR14, VEGF, hnRNP H, Oct4, Sox2, and Nanog in metastatic MGT group were significantly higher than those in non-metastatic MGT group. However, mRNA level of RPL4 was significantly lower in metastatic MGT group. Loss of E-cadherin and HPRT1 was observed in the metastatic MGT group but it was not significant. Conclusions: Consistent expression patterns of all metastasis-related factors showing elevation in ICAM-1, PRR14, VEGF, hnRNP H, Oct4, Sox2, and Nanog, but decreases in RPL4 levels occurred in canine MGT tissues, which was associated with metastasis. Thus, these cancer prognostic metastasis factors and TFs of cancer stem cells, except for E-cadherin and HPRT1, can be used as reliable metastasis factors for canine MGT and therapeutic strategy.

Enhancement of Ammonia Adsorption Performance by Impregnation of Metal Chlorides on Surface-Modified Activated Carbon (표면 개질 활성탄 위 금속 염화물의 첨착에 의한 암모니아 흡착 성능의 향상)

  • Song, Kang;Lim, Jeong-Hyeon;Kim, Cheol-Gyu;Park, Cheon-Sang;Kim, Young-Ho
    • Applied Chemistry for Engineering
    • /
    • v.32 no.6
    • /
    • pp.671-678
    • /
    • 2021
  • Effects of nitric acid treatment of an activated carbon and impregnation of metal chlorides on the activated carbon were investigated to improve ammonia adsorption performance. It was confirmed that functional groups such as hydroxyl and carboxyl groups were introduced onto a surface of the activated carbon with nitric acid treatment. Then, each metal chloride (NiCl2, MgCl2, CuCl2, MnCl2 or CoCl2) was impregnated onto the surface-modified activated carbon using an ultrasonic impregnation method. The physicochemical properties and ammonia adsorption performance of various impregnated activated carbons were observed. Metal chlorides were well dispersed by sonication and evenly distributed on the surface of the activated carbon. Despite the reduced specific surface area and pore volume, the surface-modified activated carbon impregnated with metal chlorides exhibited excellent ammonia adsorption performance. In particular, HNO3-NiCl2 AC prepared by impregnating NiCl2 showed the best ammonia adsorption capacity of 3.736 mmol·g-1, which was improved by about 57 times compared to that of an untreated activated carbon (0.066 mmol·g-1).

Structural and Electrical Properties of K(Ta,Nb)O3 Ceramics with Variation of Ag Contents for Electrocaloric Devices (전기열량소자용 Ag 첨가량에 따른 K(Ta,Nb)O3 세라믹스의 구조적·전기적 특성)

  • Lee, Min-Sung;Park, Byeong-Jun;Lim, Jeong-Eun;Lee, Sam-Haeng;Lee, Myung-Gyu;Park, Joo-Seok;Lee, Sung-Gap
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.34 no.6
    • /
    • pp.442-448
    • /
    • 2021
  • In this work, the (K1-xAgx)(Ta0.8Nb0.2)O3 (x=0.1-0.4) ceramics were fabricated using mixed-oxide method, and their structural and electrical properties were measured. All specimens represented a pseudo cubic structure with the lattice constant of 0.3989 nm. When 0.4 mol of Ag was added, second phases induced from metallic Ag and K2(Ta,Nb)6O16 phase were observed. Dielectric constant and dielectric loss of K(Ta0.8Nb0.2)O3 specimen doped with 0.3 mol of Ag were 2,737 and 0.446, respectively. The curie temperature was about -5℃, which does not change with Ag addition. The remanent polarization began to decrease sharply around 12~15℃, and the temperature at which the remanent polarization began to decrease as the applied voltage increased shifted to the high temperature side. The electrocaloric effect (ΔT) and electrocaloric efficiency (ΔT/ΔE) of the (K0.7Ag0.3)(Ta0.8Nb0.2)O3 ceramics were 0.01024℃ and 0.01825 KmV-1, respectively.

Real-time Monitoring of Temperature and Relative Humidity and Visualization of Pest Survey Data for Integrated Pest Management in Collection Storage Area (유물 공간의 종합적 유해생물 관리(Integrated Pest Management)를 위한 실시간(Real-Time) 온습도 모니터링 및 유해 생물 조사 자료의 시각화)

  • Im, Ik-Gyun;Lim, Seong-Duk;Han, Gyu-Seong
    • Journal of Conservation Science
    • /
    • v.37 no.5
    • /
    • pp.440-450
    • /
    • 2021
  • Temperature and humidity data collection using real-time sensors and data loggers was conducted for integrated pest management in the collection storage and exhibition space of the Jeongnimsaji Museum, Buyeo. The real-time temperature and humidity monitoring system collected measurement data every 30 minutes and enabled real-time confirmation of the data through a linked application. If the temperature and humidity data measured in the real-time temperature and humidity monitoring system exceeds the set range, a push notification was sent to the mobile phone of the person in charge to provide status information to establish a continuous management system. Through this, it was possible to immediately recognize and take action when the temperature range exceeded the recommended relic temperature in August. We performed data visualization on the concentration of airborne fungus in the storage area and the inflow path and density of insects. Based on the recommended criteria presented by the National Institute of Cultural Heritage, The data on the spatial and temporal concentration of airborne fungus inside the collection storage were found to be maintained at a value below the standard recommended by the National Institute of Cultural Heritage (80 CFU/m3). Also, as a result of the insect inflow survey, no insects were captured inside the storage area, and in the case of the exhibition space, insects such as Scutigera coleoptrata, Loxoblemmus arietulus, Diestrammena asynamora, Koreoniscus racovitzai were captured. Based on this, as a result of visualization according to the individual density of captured insects by area, it was confirmed that the main inflow paths of insects were the external entrance and the toilet area.

Difference in Characteristics in the Formation of Anti-E and Anti-E/-c in Patients with the CDe Phenotype (CDe 표현형의 환자에서 항-E와 항-E/-c 항체 생성 특이성의 차이)

  • An, Gyu-Dae;Kim, Kyeong-Hee;Lim, Hyeon-Ho;Jeong, In-Hwa
    • The Korean Journal of Blood Transfusion
    • /
    • v.29 no.3
    • /
    • pp.282-290
    • /
    • 2018
  • Background: Anti-E or paired anti-E/-c antibodies can develop in patients with the Rh CDe phenotype. This study examined the differences in transfusion in patients with the CDe phenotype according to formation of anti-E or anti-E/-c antibodies. Methods: Retrospective reviews were carried out on the results of antibody identification tests performed in 2014. The Rh phenotype and antibody specificity were investigated. The transfusion and medical records of patients with the CDe phenotype were examined. Results: In total, 76 patients were included in the review. Of these 76 patients, 38 (50.0%) were of the CDe phenotype. Anti-E antibodies were the most frequent (60.5%), followed by anti-E/-c antibodies (23.7%). The total transfusion units and platelet transfusion units were significantly higher in patients with anti-E/-c antibodies (P=0.028 and P=0.01, respectively). The distribution of categorized diseases was similar in the patients with the anti-E and anti-E/-c antibodies. A frequency of transfusion episodes greater than or equal to four was higher in patients with hepatobiliary diseases (85.7%). Conclusion: In CDe phenotype patients, platelet transfusion was significantly higher in the anti-E/-c positive group than the anti-E positive group, indicating that platelets play a role in red blood cell alloimmunization. Because E is the most immunogenic antigen in Korea, it is important to define the disease group, in which patients with CDe phenotype require a transfusion of E and c-negative blood.

Numerical Study of the Heat Removal Performance for a Passive Containment Cooling System using MARS-KS with a New Empirical Correlation of Steam Condensation (새로운 응축열전달계수 상관식이 적용된 MARS-KS를 활용한 원자로건물 피동냉각계통 열제거 성능의 수치적 연구)

  • Jang, Yeong-Jun;Lee, Yeon-Gun;Kim, Sin;Lim, Sang-Gyu
    • Journal of Energy Engineering
    • /
    • v.27 no.4
    • /
    • pp.27-35
    • /
    • 2018
  • The passive containment cooling system (PCCS) has been designed to remove the released decay heat during the accident by means of the condensation heat transfer phenomenon to guarantee the safety of the nuclear power plant. The heat removal performance of the PCCS is mainly governed by the condensation heat transfer of the steam-air mixture. In this study, the heat removal performance of the PCCS was evaluated by using the MARS-KS code with a new empirical correlation for steam condensation in the presence of a noncondensable gas. A new empirical correlation implemented into the MARS-KS code was developed as a function of parameters that affect the condensation heat transfer coefficient, such as the pressure, the wall subcooling, the noncondensable gas mass fraction and the aspect ratio of the condenser tube. The empirical correlation was applied to the MARS-KS code to replace the default Colburn-Hougen model. The various thermal-hydraulic parameters during the operation of the PCCS follonwing a large-break loss-of-coolant-accident were analyzed. The transient pressure behavior inside the containment from the MARS-KS with the empirical correlation was compared with calculated with the Colburn-Hougen model.

Consumer Preference Analysis of Korean Red Ginseng Tonic for Revitalizing Korean Ginseng Industry (국내 인삼산업 활성화를 위한 홍삼토닉 소비자 선호분석)

  • Jeong, Jae Won;Lim, Sungsoo;Kim, Tae-Kyun;Kim, Seung Gyu
    • Journal of agriculture & life science
    • /
    • v.52 no.6
    • /
    • pp.155-162
    • /
    • 2018
  • This study attempts to analyze the consumers' preference on Korean Red Ginseng Tonic, which is an essential product to revitalize Korean ginseng industry, using choice experiment method. The attributes used in the choice experiment were the ginseng age, good agricultural products(GAP), sugar, and price. A total of 1,796 experiments were collected and the value of each preferred attributes was estimated using a multinomial logistic model. The result shows that the products made from six-year-old and GAP(Good Agriculture Practice) approved Korean ginseng with less sugar were preferred. These estimated monetary values of marginal willingness to pay were about 94,000 KRW, 89,000 KRW, 5,000 KRW, respectively. Thus, the efforts to introduce and advertize GAP approved ginseng while developing new products with preferred attributes by general publics are necessary in the short run. In addition, we may need to consider developing the way to promote products using 4- and 5-year-old ginsengs, which are relatively underestimated in their health effectiveness but highly productive for farmers in the long run.

Investigation for the deformation behavior of the precast arch structure in the open-cut tunnel (개착식 터널 프리캐스트 아치 구조물의 변형 거동 연구)

  • Kim, Hak Joon;Lee, Gyu-Phil;Lim, Chul Won
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.1
    • /
    • pp.93-113
    • /
    • 2019
  • The behavior of the 3 hinged precast arch structure was investigated by comparing field measurements with numerical analyses performed for precast lining arch structures, which are widely used for the open-cut tunnel. According to the field measurements, the maximum vertical displacement occurred at the crown with upward displacements during the backfilling up to the crown of the arch and downward displacements at the backfill height above the crown. The final crown displacement was 19 mm upward from the original position. The horizontal displacement at the sidewall, which had a maximum horizontal displacement, occurred inward of the arch when compacting the backfill up to the crown and returned to the original position after completing the backfill construction. According to the analysis of displacement measurements, economical design is expected to be possible for precast arch structures compared to rigid concrete structures due to ground-structure interactions. Duncan model gave good results for the estimation of displacements and deformed shape of the tunnel according to the numerical analyses comparing with field measurements. The earth pressure coefficients calculated from the numerical analyses were 0.4 and 0.7 for the left and the right side of the tunnel respectively, which are agreed well with the eccentric load acting on the tunnel due to topographical condition and actual field measurements.

The Relationship Between Knowledge of Patient Safety, Nursing Professionalism and Patient Safety Management Activities in Nursing Students (간호대학생의 환자안전에 대한 지식, 간호전문직관과 환자안전관리활동의 관련성)

  • Kim, Chul-Gyu;Yu, Ha-Min;Kim, Hye-Won;Nam, A-Yeon;Roh, Hee-Sung;Bang, Da-Sol;Sin, Jin-Ui;Lee, A-Hyun;Lee, Eun-Gyeong;Jeon, Han-yong;Jeong, Se-Lim;Jung, You-Jung
    • Quality Improvement in Health Care
    • /
    • v.24 no.2
    • /
    • pp.26-40
    • /
    • 2018
  • Purpose: The objective of this study was to identify the relationship between knowledge of patient safety, nursing professionalism and patient safety management activities of nursing students with clinical practical experience. Methods: Self-administered questionnaires survey on knowledge of patient safety, nursing professionalism, and patient safety management activities were conducted for the $3^{rd}-year$ and $3^{th}-year$ nursing students. 139 questionnaires were distributed, of which, 131 were used for data analysis. Results: The scores of nursing students' knowledge of patient safety, nursing professionalism and patient safety management activities were $6.76{\pm}1.26$, $65.11{\pm}7.97$ and $67.99{\pm}7.26$, respectively. Knowledge of patient safety differed significantly according to the grade. Nursing professionalism had a difference with major satisfaction, clinical practical satisfaction, and experience of patient safety accident. Patient safety management activities were positively correlated (p<.01) with knowledge of patient safety and nursing professionalism. Patient safety management activities increased significantly with increase in the scores of knowledge of patient safety and nursing professionals. The factors that were related to patient safety management activities of nursing students were knowledge of patient safety and nursing professionalism. Knowledge of patient safety and nursing professionalism were selected as significant variables for explaining the patient safety management activities of nursing students, of which the coefficient of determination was 9.8%. Conclusion: To promote patient safety management activities of nursing students, training programs for patient safety management activities are required. Also, there is the need to increase the knowledge of patient safety and nursing professionalism of nursing students using various educational method.

Molten-Salt-Assisted Chemical Vapor Deposition for Growth of Atomically Thin High-Quality MoS2 Monolayer (용융염 기반의 화학기상증착법을 이용한 원자층 두께의 고품질 MoS2 합성)

  • Ko, Jae Kwon;Yuk, Yeon Ji;Lim, Si Heon;Ju, Hyeon-Gyu;Kim, Hyun Ho
    • Journal of Adhesion and Interface
    • /
    • v.22 no.2
    • /
    • pp.57-62
    • /
    • 2021
  • Recently, the atomically thin two-dimensional transition-metal dichalcogenides (TMDs) have received considerable attention for the application to next-generation semiconducting devices, owing to their remarkable properties including high carrier mobility. However, while a technique for growing graphene is well matured enough to achieve a wafer-scale single crystalline monolayer film, the large-area growth of high quality TMD monolayer is still a challenging issue for industrial application. In order to enlarge the size of single crystalline MoS2 monolayer, here, we systematically investigated the effect of process parameters in molten-salt-assisted chemical vapor deposition method. As a result, with optimized process parameters, we found that single crystalline monolayer MoS2 can be grown as large as 420 ㎛.