• Title/Summary/Keyword: Leakage signal

Search Result 342, Processing Time 0.021 seconds

Modeling and Control of ISOP Active-Clamp-Forward Converter for xEV Low Voltage DC/DC Converter

  • Naradhipa, Adhistira M.;Kim, Byeongwoo;Kim, Kangsan;Cho, Woosik;Choi, Sewan;Huh, Dongyoung;Kim, Soohong;Cho, Kyungrae
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.99-101
    • /
    • 2018
  • This paper present an input-series output-parallel active-clamp-forward converter for low voltage dc/dc xEV application. The converter can achieve ZVS turn-on for all switches. An accurate small signal model of the converter which includes the effect of leakage inductance is given and controller design based on modeling is described. Experimental and simulation results from a 3.2kW, 100kHz prototype are presented in order to verify the validity of the converter operation and the designed control parameters.

  • PDF

A study on cleaning process of RIE damaged silicon (반응성 이온 식각에 의해 손상된 실리콘의 세정에 관한 연구)

  • 이은구;이재갑;김재정
    • Electrical & Electronic Materials
    • /
    • v.7 no.4
    • /
    • pp.294-299
    • /
    • 1994
  • CHF$_{3}$/CH$_{4}$Ar 플라즈마에 의해 형성된 산화막 식각 잔류물의 화학구조와 이 잔류물의 제거를 위한 세정방법을 x-ray photoelectron spectroscopy를 이용하여 조사하였다. 잔류무르이 구조는 CF$_{x}$-polymer와 Si-C, Si-O 결합으로 이루어진 SiO$_{y}$ C$_{z}$ 이었다. CF$_{4}$O$_{2}$ 플라즈마에 의한 silicon light etch는 산화막 식각 잔류물인 SiO$_{y}$ C$_{z}$ 층과 손상된 실리콘 표면을 제거하엿으며 NH$_{4}$OH-H$_{2}$O$_{2}$과 HF용액으로 완전히 제거되는 CF$_{x}$-polymer/SiO$_{x}$층을 남겼다. 100.angs.정도의 silicon light etch는 minority carrier life time과 thermal wave signal값을 초기 웨이퍼 수준까지 회복시켰으며 접합누설 전류도 거의 습식 식각 공정수준까지 감소시켰다.

  • PDF

Study for shielded enclosure and rod grounding electrode (쉴딩차폐와 봉상접지에 관한 연구)

  • Kim, Ju-Chan;Kim, Sung-Sam;Choi, Jong-Gyu;Lee, Chung-Sik;Koh, Hee-Seog
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.414-417
    • /
    • 2006
  • Especially, the case which the facilities have been shielded in the building. In this case there must be suitable grounding system, and this case must be considered sufficiently to the one part of the design at the design. in addition there must be an electric leakage defense system and The case to be a criterion signal ground system. Rod type grounding electrodes is applied much and we studied the relation that rod type grounding method and shielding room as newly grounding object. in this paper, shield room is the object(target) to be established newly additionally, we try to describe about the flow of a grounding technology concept change and a ground facilities.

  • PDF

Interference Reduction Scheme for Mobile WiMAX in an Indoor environment (실내 환경의 Mobile WiMAX 시스템을 위한 간섭 완화 기술에 대한 연구)

  • Oh, Yong-Il;Ha, Kwang-Jun;Koo, Sung-Wan;Kim, Jin-Young
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2008.08a
    • /
    • pp.454-458
    • /
    • 2008
  • This article describes an interference reduction scheme for Mobile WiMAX in an indoor environment. The feasibility of user deployed femtocells in the same frequency channel as an existing macro cell network is investigated. One of the important requirements for co-channel operation of femtocells such as auto-configuration and self optimization are discussed. In femtocell deployments, leakage of the pilot signal to the outside of a house can result of the higher number of mobility events caused by passing user of macrocell. This interference effect can be minimized by reducing the pilot power using proper scheme. This paper introduces existing auto-configuration method of power control and proposed interference reduction scheme using power control for Mobile WiMAX in an indoor environment.

  • PDF

Rectifier with Comparator Using Unbalanced Body Biasing to Control Comparing Time for Wireless Power Transfer (비대칭 몸체 바이어싱 비교기를 사용하여 비교시간을 조절하는 무선 전력 전송용 정류기)

  • Ha, Byeong Wan;Cho, Choon Sik
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.11
    • /
    • pp.1091-1097
    • /
    • 2013
  • This paper presents a rectifier with comparator using unbalanced body biasing in $0.11{\mu}m$ RF CMOS process. It is composed of MOSFETs and two comparators. The comparator is used to reduce reverse leakage current which occurs when the load voltage is higher than input voltage. For the comparator, unbalanced body biasing is devised. By using unbalanced body biasing, reference voltage for comparator changing from high state to low state is increased, and it reduces time interval for leakage current to flow. 13.56 MHz 2 Vpp signal is used for input and $1k{\Omega}$ resistor and 1 nF capacitor are used for output load for simulation and experimental environment. In simulation environment, voltage conversion efficiency(VCE) is 87.5 % and Power conversion efficiency(PCE) is 50 %. When the rectifier is measured, VCE shows 90.203 % and PCE shows 45 %.

A Research on the Bandwidth Extension of an Analog Feedback Amplifier by Using a Negative Group Delay Circuit (마이너스 군지연 회로를 이용한 아날로그 피드백 증폭기의 대역폭 확장에 관한 연구)

  • Choi, Heung-Gae;Kim, Young-Gyu;Shim, Sung-Un;Jeong, Yong-Chae;Kim, Chul-Dong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.10
    • /
    • pp.1143-1153
    • /
    • 2010
  • In this paper, we propose an alternative method to increase the distortion cancellation bandwidth of an analog RF feedback power amplifier by using a negative group delay circuit(NGDC). A limited distortion cancellation bandwidth due to the group delay(GD) mismatch discouraged the use of feedback technique in spite of its powerful linearization performance. With the fabricated NGDC with positive phase slope over frequency, the feedback amplifier of the proposed topology experimentally achieved adjacent channel leakage ratio(ACLR) improvement of 15 dB over 50 MHz bandwidth at wideband code division multiple access(WCDMA) downlink band when tested with 2-carrier WCDMA signal. At an average output power of 28 dBm, ACLR of 25.1 dB is improved to obtain -53.2 dBc at 5 MHz offset.

A Novel CFR Algorithm using Histogram-based Code Domain Compensation Process for WCDMA Basestation (히스토그램 기반 코드 영역 보상 기법을 적용한 W-CDMA 기지국용 CFR 알고리즘)

  • Chang, Hyung-Min;Lee, Won-Cheol
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.12C
    • /
    • pp.1175-1187
    • /
    • 2007
  • This paper proposes a novel crest factor reduction (CFR) algorithm to be deployed on WCDMA basestation. Generally speaking, it is well described that the reduction of peak-to-average ratio (PAR) yields the possibility of using low cost power amplifier such that the basesation becomes economic However, the simple reduction of PAR could degrade the signal quality measured by either peak code domain error (PCDE) or error vector measurement (EVM), and the level of channel interference constrained by adjacent channel leakage ratio (ACLR). Regarding these imperfections, this paper introduces an effective CFR algorithm in which the function of filter-dependent CFR (FDCFR) incorporated with the histogram-based waterfilling code domain compensation (HBWCDC) carries out. To verify the performance of the proposed CFR technique, substantial simulations including comparative works are conducted with obeying W-CDMA basestation verification specification. To exploit the superiority, the performance of the proposed method is tentatively compared with that associated to the simple memoryless clipping method and the memory-required filter-dependent clipping method.

A Rapid Convergent Max-SINR Algorithm for Interference Alignment Based on Principle Direction Search

  • Wu, Zhilu;Jiang, Lihui;Ren, Guanghui;Wang, Gangyi;Zhao, Nan;Zhao, Yaqin
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.9 no.5
    • /
    • pp.1768-1789
    • /
    • 2015
  • The maximal signal-to-interference-plus-noise ratio (Max-SINR) algorithm for interference alignment (IA) has received considerable attention for its high sum rate achievement in the multiple-input multiple-output (MIMO) interference channel. However, its complexity may increase dramatically when the number of users approaches the IA feasibility bound, and the number of iterations and computational time may become unacceptable. In this paper, we study the properties of the Max-SINR algorithm thoroughly by presenting theoretical insight into the algorithm and by providing the potential of reducing the overall computational cost. Furthermore, a novel IA algorithm based on the principle direction search is proposed, which can converge more rapidly than the conventional Max-SINR method. In the proposed algorithm, it searches along the principle direction, which is found to approximately point to the convergence values, and can approach the convergence solutions rapidly. In addition, the closed-form solution of the optimal step size can be formulated in the sense of minimal interference leakage. Simulation results demonstrate that the proposed algorithm outperforms the conventional minimal interference leakage and Max-SINR algorithms in terms of the convergence rate while guaranteeing the high throughput of IA networks.

The Comparision of X-ray Detection Characteristics as Additive ratio of As in a-Se of $BrO_2/a-Se$ Film ($BrO_2/a-Se$ 필름의 a-Se에 첨가된 As 변화에 따른 X선 검출특성 비교)

  • Park, Ji-Koon;Choi, Jang-Yong;Kim, Dae-Hwan;Moon, Chi-Wung;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.424-427
    • /
    • 2002
  • In this papaer, there is a basic research for the development of the Hybrid digital radiation detector with a new system, make up for existing digital radiation detector of direct/indirect method with a weak point. for enhance the efficiency characteristics of signal response from X-ray detector using the a-Se, We make sample with various kinds of layer, through the ratio of As(0.l%,0.3%,0.5%,1%,1.5%,5%,10%). We measure net charge with a leakage current and photo current for electric charateristics. Ratio of As in a-Se consist of 7 stage, It made of using the thermal deposition system, In the made of samples, we made multi layer using the EFIRON optical adhesives from phosphor layer consist of Oxybromide$(BrO_2)$. As a result of X-ray measurement, the best result is ; leakage current(0.30nA/cm2), net charge(610.13pC/cm2/mR) when the condition is voltage(9V/um), 0.3% ratio of As in multi layer(BrO2 + a-Se)

  • PDF

Development of Wireless Real-Time Gas Detector System for Chemical Protection Performance Test of Personal Protective Equipment (화생방 보호의 성능평가를 위한 무선 실시간 가스 검출기 개발)

  • Kah, Dong-Ha
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.23 no.3
    • /
    • pp.294-301
    • /
    • 2020
  • Man-In-Simulant Test(MIST) provides a test method to evaluate chemical protective equipments such as protective garments, gloves, footwear and gas mask. The MIST chamber is built to control concentration of chemical vapor that has a activity space for two persons. Non-toxic methyl-salicylate(MeS) is used to simulate chemical agent vapor. We carried out to measure inward leakage MeS vapors by using passive adsorbent dosimeter(PAD) which are placed on the skin at specific locations of the body while man is activity according to the standard procedure in MIST chamber. But more time is required for PADs and there is concern of contamination in PADs by recovering after experiment. Therefore detector for measuring in real time is necessary. In order to analyze in real time the contamination of the personal protective equipment inside the chemical environment, we have developed a wireless real-time gas detector. The detector consists of 8 gas-sensors and 1 control-board. The control-board includes a CPU for processing a signal, a power supply unit for biasing the sensor and Bluetooth-chipset for transmission of signals to external PC. All signals from gas-sensors are converted into digital signals simultaneously in the control-board. These digital signals are stored in external PC via Bluetooth wireless communication. The experiment is performed by using protective equipment worn on manikin. The detector is mounted inside protective equipment which is capable of providing a real-time monitoring inward leakage MeS vapor. Developed detector is demonstrated the feasibility as real-time detector for MIST.