A Study on the Construction Management in Apartment Housing's Underground Parking Lot for Reduction of Water Leakage (공동주택 지하주차장 누수저감을 위한 시공관리에 관한 연구)

  • Lee, Jae-Hyun;Choi, Il-Ho;Bang, Jung-Seok;Kim, Hyo-Rak
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.11a
    • /
    • pp.181-183
    • /
    • 2011
  • This study was carried out about construction management plan to reduce water leakage of underground parking lot in the apartment housing. To minimize effect of upper working load, installation position of jack support and paving with rubble on the top of underground parking lot were studied. By calculation shrinkage strain of underground parking lot scale, water leakage risk in design of level difference was studied. In this study, the basic data about construction management was provided to reduce water leakage of underground parking lot in the apartment housing.

  • PDF

A Study on the Development of Calculation Tables and Formulas for Determining Separation Distance in Case of Cl2・HF Tank-lorry Leakage (염소・불화수소 탱크로리 누출사고 시 이격거리 산정을 위한 산정표 및 산정식 개발 연구)

  • Jeon, Byeong-Han;Kim, Hyun-Sub;Lim, Sang-Min;Lee, Joo-Chan;Lee, Gang-San
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.4
    • /
    • pp.212-219
    • /
    • 2021
  • Chemical accidents caused by transport vehicles account for 20% of all chemical accidents every year, but there are difficulties in the accident-response process due to repeated situations where the impact assessment information is unknown. In this study, we developed a calculation table and formula for predicting the range of damage for chlorine and hydrogen fluoride, which have a high domestic usage, high risk of accidents, and high accident frequency in the last 7 years. The calculation table is based on the leakage rate, wind speed, and temperature, and the calculation formula was derived using R software for special situations where it is difficult to apply the calculation table. The calculation table and formula could be used on site by related organizations to obtain important information for decision making, which could help in minimizing damage from chemical accidents, setting separation distances, and deciding to evacuate residents.

The Loss Calculation of Eddy Current of the Tank and Winding Supports in Transformers by the Leakage Flux (누설자속에 의한 대용량 변압기의 권선지지구조 및 외함의 와전류손실 계산에 관한 연구)

  • Heo, Woo-Heng;Lee, Dong-Yeup;Kim, Gyu-Tak
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.948-950
    • /
    • 2005
  • This paper compared the test data with the loss when a conductor is exposed to the magnetic fieldof reactors after generating external magnetic field in specimen by means of an air core reactor model and the calculation of loss came from a tying the combination of FEM and integral method. It was applied to the loss measurement of transformers due to leakage flux.

  • PDF

Simple Calculation Method as a Supplementary Radiation Safety Assessment for Facility with Radiation Generator

  • Kim, Sang-Tae
    • International Journal of Contents
    • /
    • v.14 no.4
    • /
    • pp.65-69
    • /
    • 2018
  • The objective of this study was to conduct a radiation shielding analysis for the facility equipped with radiation generator. The analysis was carried out in two aspects. First, from the aspect of the effect caused by primary and leakage radiation. Second, effect of scattered radiation was evaluated by applying a simple calculation method based on a scattering rate concept since effect of scattered radiation is significantly important at maze entrance of the radiation facility. The calculated results obtained using the simple method were compared to the results calculated using Geant4 code and the measured values. The results calculated by the suggested method indicate that slight error exists in a radiation shielding analysis done at the maze entrance comparing to other two results, while the results evaluated at the outside of the maze entrance door are relatively consistent with other values.

Dynamic Behavior Analysis of a Orbiting Scroll in Scroll Compressor with Tangential Leakage (접선방향의 누설이 고려된 스크롤 압축기 선회 스크롤의 동적 거동 해석)

  • 김태종;한동철
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1996.05a
    • /
    • pp.41-46
    • /
    • 1996
  • For a vertical type crankshaft-journal bearing system used in scroll compressor, nonlinear transient response analysis is applied includung nonlinear fluid film reaction forces of journal beatings. By a connected behavior analysis of crankshaft and orbiting scroll, the radial clearance of scroll wraps is calculated. Considering tangential leakage for this clearance, a coupled analysis model for leakage and dynamic behavior of the orbiting scroll is made, and analyzed by iterative calculation. By regarding clearances of main, sub bearing of crankshaft and orbiting scroll shaft bearing clearance as design parameters, the radial clearance of scroll wraps is analyzed.

  • PDF

High performance 3D pin-by-pin neutron diffusion calculation based on 2D/1D decoupling method for accurate pin power estimation

  • Yoon, Jooil;Lee, Hyun Chul;Joo, Han Gyu;Kim, Hyeong Seog
    • Nuclear Engineering and Technology
    • /
    • v.53 no.11
    • /
    • pp.3543-3562
    • /
    • 2021
  • The methods and performance of a 3D pin-by-pin neutronics code based on the 2D/1D decoupling method are presented. The code was newly developed as an effort to achieve enhanced accuracy and high calculation performance that are sufficient for the use in practical nuclear design analyses. From the 3D diffusion-based finite difference method (FDM) formulation, decoupled planar formulations are established by treating pre-determined axial leakage as a source term. The decoupled axial problems are formulated with the radial leakage source term. To accelerate the pin-by-pin calculation, the two-level coarse mesh finite difference (CMFD) formulation, which consists of the multigroup node-wise CMFD and the two-group assembly-wise CMFD is implemented. To enhance the accuracy, both the discontinuity factor method and the super-homogenization (SPH) factor method are examined for pin-wise cross-section homogenization. The parallelization is achieved with the OpenMP package. The accuracy and performance of the pin-by-pin calculations are assessed with the VERA and APR1400 benchmark problems. It is demonstrated that pin-by-pin 2D/1D alternating calculations within the two-level 3D CMFD framework yield accurate solutions in about 30 s for the typical commercial core problems, on a parallel platform employing 32 threads.

Numerical Analysis on the Blade Tip Clearance Flow in the Axial Rotor (II) - Variation of Leakage Vortex with Tip Clearance and Attack Angle - (축류 회전차 익말단 틈새유동에 대한 수치해석(II) - 틈새변화 및 영각변화에 따른 누설와류의 변화 -)

  • Ro, Soo-Hyuk;Cho, Kang-Rae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.9
    • /
    • pp.1106-1112
    • /
    • 1999
  • Substantial losses behind axial flow rotor are generated by the wake, various vortices in the hub region and the tip leakage vortex in the tip region. Particularly, the leakage vortex formed near blade tip is one of the main causes of the reduction of performance, generation of noise and aerodynamic vibration in downstream. In this study, the three-dimensional flow fields in an axial flow rotor were calculated with varying tip clearance under various flow rates, and the numerical results were compared with experimental ones. The numerical technique was based on SIMPLE algorithm using standard $k-{\varepsilon}$ model(WFM) and Launder & Sharma's Low Reynolds Number $k-{\varepsilon}$ model(LRN). Through calculations, the effects of tip clearance and attack angle on the 3-dimensional flow fileds behind a rotor and leakage flow/vortex were investigated. The presence of tip leakage vortex, loci of vortex center and its behavior behind the rotor for various tip clearances and attack angles was described well by calculation.

The Leakage Crack Calculation of the Fire Door and the Stack Effect Analysis (방화문의 누설틈새 계산 및 연돌효과 분석)

  • Kim, Il-Young;Kwon, Chang-Hee
    • Fire Science and Engineering
    • /
    • v.27 no.2
    • /
    • pp.46-53
    • /
    • 2013
  • The architecture environment has changed. The corresponding design criteria should be changed. From July 27th, 2005 the Korea Standard of the fire door changed concerning the smoke resistance test which made the door gap structure more elaborate. However the National Fire Safety Codes are applied by the old data's of England. Which in case differs in the actual construction to the blue print, making the safety standard too excessive. Analyze the results and the phenomenon that occurs due to the difference between design and reality. The National Fire Safety Codes should be revised to leakage crack calculation is presented. Difference of the air flow for the smoke protection due to the stack effect analyzed. Living patterns and evacuation patterns of the apartment reflect and reasonable air flow measurement method are presented.

PWR core calculation based on pin-cell homogenization in three-dimensional pin-by-pin geometry

  • Bin Zhang;Yunzhao Li;Hongchun Wu;Wenbo Zhao;Chao Fang;Zhaohu Gong;Qing Li;Xiaoming Chai;Junchong Yu
    • Nuclear Engineering and Technology
    • /
    • v.56 no.6
    • /
    • pp.1950-1958
    • /
    • 2024
  • For the pressurized water reactor two-step calculation, the traditional assembly homogenization and two-group neutron diffusion calculation have been widely used. When it comes to the core pin-by-pin simulation, many models and techniques are different and unsettled. In this paper, the homogenization methods based on the pin discontinuity factors and super homogenization factors are used to get the pin-cell homogenized parameters. The heterogeneous leakage model is applied to modify the infinite flux spectrum of the single assembly with reflective boundary condition and to determine the diffusion coefficients for the SP3 solver which is used in the core simulation. To reduce the environment effect of the single-assembly reflective boundary condition, the online method for the SPH factors updating is applied in this paper, and the functionalization of SPH factors based on the least-squares method will be pre-made alone with the table of the group constants. The fitting function will be used to update the thermal-group SPH factors with a whole-core pin-by-pin homogeneous solution online. The three-dimensional Watts Bar Nuclear Unit 1 (WBN1) problem was utilized to test the performance of pin-by-pin calculation. And numerical results have demonstrated that PWR pin-by-pin core calculation has more accurate results compared with the traditional assembly-homogenization scheme.

Fractal Analysis of the Carbonization Pattern Formed on the Surface of a Phenolic Resin (페놀수지 표면에 형성된 탄화패턴에 대한 프랙탈 해석)

  • Kim, Jun-Won;Park, Sang-Taek;Roh, Young-Su
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.1
    • /
    • pp.124-129
    • /
    • 2010
  • When a phenolic resin is carbonized by the leakage current flowing along its surface, the carbonization pattern is one of the most important factors to determine its carbonization characteristics. However, the typical carbonization pattern of a phenolic resin is too complicated to be analyzed by conventional Euclidean geometry. In most cases, such a complicated shape shows a fractal structure. It is possible, therefore, to examine the characteristics of the carbonization pattern regarding a given phenolic resin. In order to quantitatively investigate the carbonization pattern of the phenolic resin carbonized by a leakage current, in this paper, the fractal dimension of the carbonization pattern has been calculated as a function of the magnitude of a leakage current and the distance between two electrodes. For reliability of calculation, the correlation function as well as the box counting method has been used to calculate the fractal dimension. According to the result of calculation, the fractal dimension increases as the current increases at the constant electrode gap distance. However, there is no significant relation between the fractal dimension and the electrode gap distance at a constant current.