Watertightness Property Evaluation of Rain-Block System (개폐식 대공간 구조물에서 지붕 맞댐부 우수차단 시스템의 수밀성 평가에 관한 연구)

  • Kim, Yun-Ho;Baek, Ki-Youl;Kim, Jong-Su;Lee, Sun-Gyu;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2010.05a
    • /
    • pp.13-16
    • /
    • 2010
  • This study is an Investigation on the Watertightness Properties of Rain-Block System on the Sliding-Roof Joint of Large-Span Membrane Structures. In this experimental, we test the watertightness performance of joint part of sliding door in roof of large span membrane structure(for pilot project) under environment of rain and wind. A shape of rain water blocking systems of joint part in sliding door verifies the defects and effects of water leakage prevention in precipitation with the wind conditions. For obtaining watertightness of large span membrane structures, it is necessary quality of joints and performance, and quality of membrane material of a retractable roof as well as a closed roof. Also, for obtaining quality in joints, it is essential to make a watertightness guideline for design of large-span membrane.

  • PDF

A Study on Compressor Seal for Automotive Air-conditioner using Polymer Resin (고분자 수지를 이용한 자동차 에어컨용 압축기의 씰에 관한 연구)

  • 정태형;하영욱
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.11 no.5
    • /
    • pp.81-87
    • /
    • 2002
  • The existing compressor steel seal used in automotive air-conditioner has the problem of oil leakage and deterioration in shielding performance, due to the abrasion and corrosion of the material. A new type of polymer resin seal studied in this research has the characteristics of high anti-abrasiveness and anti-corrosiveness, which can oversome the defects of the steel seal. In addition, the seal needs lower manufacturing cost and is appropriate to mass production, because it is made by the injection molding method requiring no mechanical processing. The profile generation program for seal mold has been developed using the gradient method, and the molding characteristics of the seal have analyzed through the flow analysis and the warpage analysis. The program has been verified by comparing the analysis results with the measured data of the test product. The research might be said to provide the basic method to produce the polymer resin seals with various types and dimensions.

Comparison of shallow junction properties depending on ion implantation and annealing conditions (이온주입 및 열처리 조건에 따른 박막접합의 특성 비교)

  • 홍신남;김재영
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.7
    • /
    • pp.94-101
    • /
    • 1998
  • To form 0.2 .mu.m p$^{+}$-n junctions, BF$_{2}$ ions with the energy of 20keV and the dose of 2*10$^{15}$ cm$^{-2}$ were implanted into the crystalline and preamorphized silicon substrates. Th epreamorphization was performed using 45keV, 3*10$^{14}$ cm$^{-2}$ As or Ge ions. Th efurnace annealing and rapid thermal annealing were empolyed to annihilate the implanted damage and to activate the implanted boron ions.The junction properties were analyzed with the measured values of the junction depth, sheet resistances, residual defects, and leakage currents. The thermal cycle of furnace annela followed by rapid thermal annela shows better characteristics than the annealing sequence of rapid thermal anneal and furnace annela.Among the premorphization species, Ge ion exhibited the better characteristics than the As ion.n.

  • PDF

Image Processing Technique for an Automatic Inspection of the Surface Outlook of High Speed Moving Plate. (고속 이동 판재의 자동 외관 검사를 위한 영상처리)

  • 부광석;임성현;조현춘
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.219-219
    • /
    • 2000
  • A Plate type pipe is used for heat exchange in radiator of a vehicle. The pipe has several rooms through which water flows and heat is dissipated into outside . In the case that there are small holes, cracks or some scratches on the plate, the radiators lost their functions due to Leakage. This may result in overheating of engine in a car. Thus, we need to perform the entire inspection of the plate type pipe in advance before assembling the radiator. In manufacturing process of the plate type pipe, the productive speed is very high and that may be performed continuously. So, there is no room to perform the outlook inspection by typical image processing techniques. This paper proposes a new method to inspect the outlook surface of the plate type pipe automatically with high speed. Especially, the sequential processing technique of an algorithm which detects defects on the surfaces of the plate type pipe is proposed for line scan camera which captures line image. To evaluate the inspection performance, a series of experiments is performed.

  • PDF

Application Method of Integrated Information System on waterproofing Quality for Improving Structure Durability (구조물 내구성 향상을 위한 방수품질 관련 통합정보시스템 활용방안에 관한 연구)

  • Kang, Hyo-Jin;An, Ki-Won;Kim, Byoung-il;Oh, Sang-keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.339-340
    • /
    • 2018
  • Contemporary concrete structures make use of underground spaces as parking lots and other comfort facilities for efficiency purposes. As underground environmental conditions are in constant exposure to degradation factors from the environment such as groundwater, hydraulic and soil pressure, structural movement and settlement, structural defects in the form of leakage occur. Current maintenance regulations and regimes are unable to respond to this field, as degradation mechanisms in underground environments are still unclear. In this regard, this study proposes the utilization of integrated information sharing system that can provide various technical information for construction designs to prevent leakages in underground concrete structures.

  • PDF

Activation of Implanted tons by Microwave Annealing (마이크로 웨이브를 이용한 이온의 활성화 방법에 관한 연구)

  • Kim, Cheon-Hong;Yoo, Juhn-Suk;Park, Cheol-Min;Han, Min-Koo
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1630-1632
    • /
    • 1997
  • We have investigated activation phenomena of implanted ions on silicon wafers using microwave(2.45GHz). It is found that the higher concentration of impurities makes the better activation effects by microwave annealing. We have exposed poly-Si TFTs by microwave in order to anneal and improved the device performance. Microwave activates source/drain ions and lowers the contact resistance so that the current of the poly-Si TFTs increases. In addition, the leakage current of hydrogen passivated poly-Si TFTs is decreased after microwave annealing, due to the diffusion of hydrogen ions and curing the defects in the poly-Si active channel.

  • PDF

High Dose $^{60}Co\;{\gamma}$-Ray Irradiation of W/GaN Schottky Diodes

  • Kim, Jihyun;Ren, F.;Schoenfeld, D.;Pearton, S.J.;Baca, A.G.;Briggs, R.D.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.4 no.2
    • /
    • pp.124-127
    • /
    • 2004
  • W/n-GaN Schottky diodes were irradiated with $^{60}Co\;{\gamma}-rays$ to doses up to 315Mrad. The barrier height obtained from current-voltage (I-V) measurements showed minimal change from its estimated initial value of ${\sim}0.4eV$ over this dose range, though both forward and reverse I-V characteristics show evidence of defect center introduction at doses as low as 150 Mrad. Post irradiation annealing at $500^{\circ}C$ increased the reverse leakage current, suggesting migration and complexing of defects. The W/GaN interface is stable to high dose of ${\gamma}-rays$, but Au/Ti overlayers employed for reducing contact sheet resistance suffer from adhesion problems at the highest doses.

An Experimental Study on the Outside Waterproofing Construction Method of Underground Structures Using the High-Adhesion and High-Elasticity of Unvulcanized Sheet (비가황 고점착.고탄성의 균질시트를 이용한 지하 외방수공법에 관한 실험적 연구)

  • Shao, Xu-Dong;Kim, Seon-Hwa;Kwon, Ki-Joo;Kwak, Kyu-Sung;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.05b
    • /
    • pp.225-229
    • /
    • 2009
  • It has been found that existing detects at the junction between waterproofing layer as well as the material and the surfaces of the construction when waterproofing sheet is employed in the currently used unground structures waterproofing technology, causing a series of problems such as the high cost to the maintenance for leakage and the durability. The purpose of this study is about reducing the waterpoofing defects in underground structures. consequently, the homogeneous sheet which has some quality such as the unvulcanizate, high-adhesion and high-elastic was examined on physical properties. As a test result, it was confirmed to have satisfied performance about the ks. However, it must be continued to study through mock-up test for confirming of site application.

  • PDF

Electrical Characteristics Test of Distribution Polymer Lightening Arresters (배전용 폴리머 피뢰기의 전기적 특성시험)

  • Kwon, Tae-Ho;Lee, Byung-Sung;Song, Il-Keun;Kim, Dong-Myung;Yoon, Tae-Sang;Jung, Sang-Bong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.546-549
    • /
    • 2004
  • This paper describes the electrical characteristics of the polymer lightning arresters(L.As) used to protect distribution lines and power facilities from surge. For the relative comparison, the characteristics assessment was done for 2 states of L.As before and after water immersion treatment. The L.As for the comparative test were immersed with water of $95[^{\circ}C]$ considered a severe condition. After the immersion treatment, the assessment was carried out for material analyses in chemical structure(FTIR : fourier transform infrared spectrophotometer). Electrical performance measured insulation resistance measurement, leakage current measurement, critical operation voltage measurement etc.. In addition to, the results were compared with those for the L.As deteriorated in the field. Thus, the accelerative deterioration degree of polymer materials by immersion treatment was evaluated, by which the structural defects of the polymer L.As could be inferred.

  • PDF

Bonding Property of Silicon Wafer Pairs with Annealing Method (열처리 방법에 따른 실리콘 기판쌍의 접합 특성)

  • 민홍석;이상현;송오성;주영창
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.5
    • /
    • pp.365-371
    • /
    • 2003
  • We prepared silicon on insulator(SOI) wafer pairs of Si/1800${\AA}$ -SiO$_2$ ∥ 1800${\AA}$ -SiO$_2$/Si using water direct bonding method. Wafer pairs bonded at room-temperature were annealed by a normal furnace system or a fast linear annealing(FLA) equipment, and the micro-structure of bonding interfaces for each annealing method was investigated. Upper wafer of bonded pairs was polished to be 50 $\mu\textrm{m}$ by chemical mechanical polishing(CMP) process to confirm the real application. Defects and bonding area of bonded water pairs were observed by optical images. Electrical and mechanical properties were characterized by measuring leakage current for sweeping to 120 V, and by observing the change of wafer curvature with annealing process, respectively. FLA process was superior to normal furnace process in aspects of bonding area, I-V property, and stress generation.