• Title/Summary/Keyword: Leak noise

Search Result 79, Processing Time 0.026 seconds

A Study on the Evaluation of Internal Leak in Valve for Nuclear Power Plant Using Acoustic Emission Method (음향방출법에 의한 원자력발전소 밸브내부 누설평가에 관한 연구)

  • Lee, Sang-Guk;Lee, Sun-Ki;Lee, Jun-Shin
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.284-289
    • /
    • 2004
  • The objective this study is to estimate the feasibility of acoustic emission method for the internal leak from the valves in nuclear power plants. From the experimental results, it was suggested that the acoustic emission method for monitoring of leak was feasible. When the background levels are higher than the acoustic signals from leak, we can detect the leak analyzing the spectrum of the remainders which take the background noise from the acoustic signals.

  • PDF

Development of leakage test facility for leak signal characteristic analysis in water pipeline (상수도관로 누수신호의 특성 분석을 위한 누수 실험시설 개발)

  • Park, Sanghyuk;Kwak, Philljae;Lee, Hyundong;Choi, Changho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.5
    • /
    • pp.459-469
    • /
    • 2017
  • A real scale leakage test facility was developed to study the leak signal characteristics of water supply pipelines, and then leak tests were carried out. The facility was designed to overcome the limited experimental circumstances of domestic water supply pipeline experimental facilities. The length of the pipeline, which was installed as a straight line, is 280m. Six pipes were installed on a 70m interval with different pipe material and diameters that are DCIP(D200, D150, D100, D80), PE(D75) and PVC(D75).The intensity of the leakage is adjusted by changing the size of the leak hole and the opening rate of ball valve. Various pressure conditions were simulated using a pressure reducing valve.To minimize external noise sources which, deteriorate the quality of measured leak signal, the facility was built at a quiet area, where traffic and water consumption by customers is relatively rare. In addition, the usage of electric equipment was minimized to block out noise and the facility was operated using manual mode. From the experimental results of measured leakage signal at the facility, it was found that the signal intensity weakened and the signal of high frequency band attenuated as the distance from the water leakage point increased.

Oil leak detection on a plant by using CCTV camera (CCTV 카메라를 이용한 플랜트 오일 누설 감시)

  • Son, Ki-Sung;Jeon, Seop-Hyeong;Choi, Young-Chul;Park, Jong-Won
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.136-141
    • /
    • 2011
  • In a power plant, an oil and steam leakage is generated once in a while. This is because the operating temperature and pressure of oil are very high. It is very difficult to monitor oil leakage, because oil leakage is almost invisible. Therefore a method to oil leakage detecting quickly and accurately is needs. In this paper, we proposed the method for the detecting oil leakage by using image processing and CCTV. To test the performance of this technique, experiments have been performed for simple case. Results show that the proposed technique is quite powerful in the oil leak detection.

  • PDF

A Study on Leak Detection Technique of a Pipe In a Noisy Environment (기계잡음 환경에서의 배관 누설탐지기법에 관한 연구)

  • Yoon, Doo-Byung;Park, Jin-Ho;Shin, Sung-Hwan
    • The Journal of the Acoustical Society of Korea
    • /
    • v.31 no.7
    • /
    • pp.449-460
    • /
    • 2012
  • The importance of the leak detection of a buried pipe in a power plant of Korea is being emphasized as the buried pipes of a power plant are more than 20 years old. The objective of this work is to enhance the capability of the leak detection technique in a noisy environment. For this purpose, a modified cross-correlation method that can effectively remove the rotating machinery noise component is suggested. In addition, a method for leak point detection using phase information of cross-spectrum is suggested. The validity of the proposed method is verified by performing an experiment. The experimental result demonstrates that the performance of the cross-correlation method can be enhanced by reducing the periodic noise components due to mechanical equipment.

Leak Location Detection of Underground Water Pipes using Acoustic Emission and Acceleration Signals (음향방출 및 가속도 신호를 이용한 지하매설 상수도배관의 누수지점 탐지연구)

  • Lee, Young-Sup;Yoon, Dong-Jin;Jeong, Jung-Chae
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.3
    • /
    • pp.227-236
    • /
    • 2003
  • Leaks in underground pipelines can cause social, environmental and economical problems. One of relevant countermeasures against leaks is to find and repair of leak points of the pipes. Leak noise is a good source to identify the location of leak points of the pipelines. Although there have been several methods to detect the leak location with leak noise, such as listening rods, hydrophones or ground microphones, they have not been so efficient tools. In this paper, acoustic emission (AE) sensors and accelermeters are used to detect leak locations which could provide all easier and move efficient method. Filtering, signal processing and algorithm of raw input data from sensors for the detection of leak location are described. A 120m-long pipeline system for experiment is installed and the results with the system show that the algorithm with the AE sensors and accelerometers offers accurate pinpointing of leaks. Theoretical analysis of sound wave propagation speed of water in underground pipes, which is critically important in leak locating, is also described.

Study on the Comparison of Piezoelectric Property of Acoustic Sensor for Valve Leak Diagnosis (밸브누설 진단용 PZT 및 Pb-Free 음향센서의 압전특성 비교 연구)

  • Lee, Sang-Guk;Park, Sung-Keun
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3383-3388
    • /
    • 2007
  • To compare the sensor performance of AE leak diagnosis system which can measure valve leak conditions, AE activities such as RMS voltage level, AE signal trend, leak rate degree according to AE database, FFT spectrum were measured on valve of the simulated test system for power plant. AE activities were recorded and analyzed from various operating conditions including different temperature, pressure difference, valve size and fluid using both piezoelectric acoustic emission sensor and Pb-Free acoustic emission sensor. The results of this study are utilized to select the type of sensors, the frequency band for filtering and thereby to improve the signal-to-noise ratio for diagnosis or monitoring of valves in operation. As the final result of application study above, portable type leak diagnosis system by AE was developed. The outcome of the study can be definitely applied as a means of the diagnosis or monitoring system for energy saving and prevention of accident for power plant valve.

  • PDF

Leak detection in a pipeline based on estimation theory

  • Jeong, Sang-Hun;Bang, Sung-Ho;Lee, Kwang-Soon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10b
    • /
    • pp.170-175
    • /
    • 1992
  • A leak detection method for diagnosis of the leak position in a pipeline was developed using an estimation theory with the assumption that the measured flow rates and pressures are stochastic processes. A notch filter was designed using power spectral density analysis of measurements to reduce the effects of disturbances. The noise model dimension was determined by hypothesis testing and then recursive extended least square method was applied to estimate the leak position in real time. The proposed method was applied to an experimental system for evaluation of its performance.

  • PDF

Improvement of Acoustic Emission Signal Processing Method and Source Location using Wavelet Transform (웨이블릿 변환을 이용한 음향방출 신호의 처리기법 개선 및 위치표정)

  • Kim, Dong-Hyun;Park, Il-Suh;Chung, Won-Yong;Park, Yong-Suk
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.9 no.1
    • /
    • pp.10-17
    • /
    • 2008
  • The purpose of this thesis is to reduce of error for source location through acoustic emission(AE) signal, generated elastic wave from crack growth to leak for facility diagnosis. Especially, in order to overcome noise from original signal, this paper proposed enhancement of source location by using noise reduction based on wavelet transform. To evaluate actual performance in experiments, Pencil Lead Break is used crack signal source on the aluminum plate and drain valve of air compressor is used as substitute pressure vessel to generate leak signal. In signal processing, wavelet shrinkage and soft threshold are used to discriminate signal source and then source location techniques have been effectively used with group velocity using material property and time difference between sensor using cross correlation. Source location for crack and leak test have some difference, but the result show that improved 30% with a average length within 10.46mm in crack test and improved 2% compare with average filter in leak test when we applied wavelet transform.

  • PDF