• Title/Summary/Keyword: LC/MS analysis

Search Result 751, Processing Time 0.036 seconds

Determination of acidic pharmaceuticals in aquatic environmental samples by LC/ESI-MS/MS (LC/ESI-MS/MS를 이용한 수질 환경 시료 중 산성의약물질 분석방법 비교)

  • Sim, Young-Eun;Cho, Hyun-Woo;Myung, Seung-Woon
    • Analytical Science and Technology
    • /
    • v.21 no.3
    • /
    • pp.191-200
    • /
    • 2008
  • Pharmaceuticals and personal care products (PPCPs) are emerging contaminants in aquatic environmental samples. Therefore, it required rapidly and certainly analytical method for pharmaceuticals which are existed in environment. In this study, Liquid chromatography/tandem mass spectrometry (LC-MS/MS) with electrospray ionization (ESI) was used to measure the concentrations of 7 pharmaceuticals (quinoxaline-2-carboxylic acid, acetylsalicylic acid, diclofenac-Na, naproxen, ibuprofen, mefenamic acid, talniflumate) from environmental water or aquatic samples simultaneously. Effective sample clean-up by solid-phase extraction (SPE) prior to LC-MS/MS analysis is necessary. For further purification, Mixed Cation eXchange (MCX) and Hydrophilic-Lipophilic Balance (HLB) solid-phase extraction (SPE) cartridges were used to eliminate the remaining interferences. LODs (Limits of Detection) and MDLs (Method Detection Limits) for the spiked sample in fresh water were in the range of 0.05~1.50 pg/mL and 0.17~4.90 pg/mL, respectively. The absolute recovery in the concentration of 1.0 ng/mL were between 81.9 and 116.3%. The acidic pharmaceuticals were detected in concentrations of 0.018~16.925 ng/mL in aquatic environmental samples.

LC-MS/MS Profiling-Based Secondary Metabolite Screening of Myxococcus xanthus

  • Kim, Ji-Young;Choi, Jung-Nam;Kim, Pil;Sok, Dai-Eun;Nam, Soo-Wan;Lee, Choong-Hwan
    • Journal of Microbiology and Biotechnology
    • /
    • v.19 no.1
    • /
    • pp.51-54
    • /
    • 2009
  • Myxobacteria, Gram-negative soil bacteria, are a well-known producer of bioactive secondary metabolites. Therefore, this study presents a methodological approach for the high-throughput screening of secondary metabolites from 4 wild-type Myxococcus xanthus strains. First, electrospray ionization mass spectrometry (ESI-MS) was performed using extracellular crude extracts. As a result, 22 metabolite peaks were detected, and the metabolite profiling was then conducted using the m/z value, retention time, and MS/MS fragmentation pattern analyses. Among the peaks, one unknown compound peak was identified as analogous to the myxalamid A, B, and C series. An analysis of the tandem mass spectrometric fragmentation patterns and HR-MS identified myxalamid K as a new compound derived from M. xanthus. In conclusion, LC-MS/MS-based chemical screening of diverse secondary metabolites would appear to be an effective approach for discovering unknown microbial secondary metabolites.

A Study on Contents of Anti-impotence drug/drug-like compounds in Food (식품중 발기부전 치료제 및 유사물질 함량에 관한 조사연구)

  • Hong, Hae-Geun;Bang, Seon-Jae;Park, Kwang-Hee;Lee, In-Sook;Park, In-Jung;Park, Jeung-Hwa;Kim, Jong-Chan
    • Journal of environmental and Sanitary engineering
    • /
    • v.22 no.3
    • /
    • pp.89-96
    • /
    • 2007
  • To determine 8 anti-impotence drug/drug-like compounds such as sildenafil, vardenafil, tadalafil, homosildenafil, hydroxyhomosildenafil, aminotadalafil, pseudovardenafil and hongdenafil in foods, simultaneously, high performance liquid chromatography(HPLC) and liquid chromatography-mass spectrometry (LC/MS) were used. The HPLC/UV analysis was performed on a column of capcellpak $C_{18}$ with 0.1% sodium-1-hexansulfonate in 0.2M ammonium formate/acetonitrile as a mobile phase. Mass spectra of the compounds by LC/MS were investigated with SCAN mode(Mass range and Fragment voltage) and SIM(Selected Ion Monitoring) mode (Ion target and Fragment voltage). The results follow as; 1. The HPLC/UV analysis was detected from 5 out of 63 samples. The content of sildenafil was in the range of 32.80 ppm ${\sim}$ 60.13 ppm from 4 out of 5 samples. The contents of sildenafil, vardenafil, homosildenafil were in the range 47.14 ppm from 1 out of 5 samples. 2. The conformed result of LC/MS was equal of detected from 5 out of 63 samples in HPLC/UV analysis. An easily available, simultaneous determination of 8 standards in adulterated health related foods was established by using a combination of LC/MS methods.

A New Analytical Method for Erythromycin in Fish by Liquid Chromatography/Tandem Mass Spectrometry

  • Park, Mi-Jung;Park, Mi-Seon;Lee, Tae-Seek;Shin, Il-Shik
    • Food Science and Biotechnology
    • /
    • v.17 no.3
    • /
    • pp.508-513
    • /
    • 2008
  • Erythromycin has been used to treat Streptococosis, Edwardsiel1osis, Vibriosis, Bacterial enteritis in the cultured fish. In this study, a rapid and effective erythromycin analysis method with new sample treatment protocol and liquid chromatography/tandem mass spectrometry (LC/MS/MS) system for fish products was developed. For the erythromycin extraction from fish muscle, the solvent mixture composed of 0.2% meta-phosphoric acid and methanol (6:4) showed good recovery rate, and the optimum extraction solvent volume was 20 mL. Erythromycin detection using LC/MS/MS were carried out under electro spray ionization (ESI) positive condition and erythromycin mass value 576.2 and 157.9. And the detection limit of the established method was 0.005 mg/kg in fish products. The recovery rate of the developed method applied to the fish species were as following, olive flounder, $87.6{\pm}5.0%$; black rockfish, $87.2{\pm}6.4%$; eel, $85.2{\pm}4.8%$; and rainbow trout, $86.0{\pm}6.2%$. In the established method in this study, the correlation of coefficient values ($R^2$) of erythromycin calibration curve (n=11) was 0.9998.

Quantitative Analysis of the Twenty Marker Components in Gwakhyangjeonggi-san using Ultra-Performance Liquid Chromatography with Mass Spectrometer (LC-MS/MS를 이용한 곽향정기산(藿香正氣散) 추출물 중 20종 성분의 함량분석)

  • Seo, Chang-Seob;Shin, Hyeun-Kyoo
    • Korean Journal of Pharmacognosy
    • /
    • v.45 no.2
    • /
    • pp.113-120
    • /
    • 2014
  • Generally, Gwakhyangjeonggi-san has been used for treatment of diarrhea-predominant irritable bowel syndrome. In this study, an ultra-performance liquid chromatography-electrospray ionization-mass spectrometer method was established for the simultaneous quantification of marker compounds 1-20 in Gwakhyangjeonggi-san water extract. All analytes were separated by gradient elution using two mobile phases on a UPLC BEH $C_{18}$ ($100{\times}2.1mm$, $1.7{\mu}m$) column and maintained at $45^{\circ}C$. The injection volume was $2.0{\mu}L$ and the flow rate was 0.3 mL/min with detection at mass spectrometer. Regression equations of the compounds 1-20 were acquired with $r^2$ values ${\geq}0.9950$. The values of limit of detection and quantification of all analytes were 0.01-2.79 ng/mL and 0.03-8.37 ng/mL, respectively. The amounts of the compounds 1-20 in Gwakhyangjeonggi-san water extract were not detected $-3,236.67{\mu}g/g$. The established LC-MS/MS methods will be valuable to improve quality control of traditional herbal formula, Gwakhyangjeonggi-san.

Liquid Chromatography-Tandem Mass Spectrometry Analysis of Riboflavin in Beagle Dog Plasma for Pharmacokinetic Studies

  • Jeong, Hyeon Myeong;Shin, Beom Soo;Shin, Soyoung
    • Mass Spectrometry Letters
    • /
    • v.11 no.1
    • /
    • pp.10-14
    • /
    • 2020
  • Riboflavin is a water-soluble vitamin, which serves as a precursor to flavin mononucleotide and flavin adenine dinucleotide. This study aimed to develop a simple and rapid liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis for the quantification of riboflavin in the Beagle dog plasma. This method utilized simple protein precipitation with acetonitrile and 13C4, 15N2-riboflavin was used as an internal standard (IS). For chromatographic separation, a hydrophilic interaction liquid chromatography (HILIC) column was used with gradient elution. The mobile phase consisted of 0.1% (v/v) aqueous formic acid with 10 mM ammonium formate and acetonitrile with 0.1% (v/v) formic acid. Since riboflavin is an endogenous compound, 4% bovine serum albumin in phosphate buffered saline was used as a surrogate matrix to prepare the calibration curve. The quantification limit for riboflavin in the Beagle dog plasma was 5 ng/mL. The method was fully validated for its specificity, sensitivity, accuracy and precision, recovery, and stability according to the US FDA guidance. The developed LC-MS/MS method may be useful for the in vivo pharmacokinetic studies of riboflavin.

Determination of cut-off value by receiver operating characteristic curve of norquetiapine and 9-hydroxyrisperidone concentrations in urine measured by LC-MS/MS

  • Kim, Seon Yeong;Shin, Dong Won;Kim, Jin Young
    • Analytical Science and Technology
    • /
    • v.34 no.2
    • /
    • pp.78-86
    • /
    • 2021
  • The objective of this study was to investigate urinary cut-off concentrations of quetiapine and risperidone for distinction between normal and abnormal/non-takers who were being placed on probation. Liquid chromatography-tandem mass spectrometric (LC-MS/MS) method was employed for determination of antipsychotic drugs in urine from mentally disordered probationers. The optimal cut-off values of antipsychotic drugs were calculated using receiver operating characteristic (ROC) curve analysis. The sensitivity and specificity of the method for the detection of antipsychotic drugs in urine were subsequently evaluated. The area under the ROC curve (AUC) was 0.927 for norquetiapine and 0.791 for 9-hydroxyrisperidone, respectively. These antipsychotic drugs are classified readily in the ROC curve analysis. The cut-off values for distinguishing regular and irregular/non-takers were 39.1 ng/mL for norquetiapine and 67.9 ng/mL for 9-hydroxyrisperidone, respectively. The results of this study suggest the cut-off values of quetiapine and risperidone were highly useful to distinguish regular takers from irregular/non-takers.

Simultaneous Quantification of Urinary L-, and D-Lactate by Reversed-Phase Liquid Chromatography Tandem Mass Spectrometry (액체크로마토그래프-탠덤질량분석기(LC-MS/MS)를 이용한 소변 내 D-, L- Lactate 분리 및 정량)

  • Moon, Chul Jin;Yang, Song Hyun
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.15 no.2
    • /
    • pp.59-64
    • /
    • 2015
  • Purpose: Lactate has two optical isomers, L-lactate and D-lactate. In human L-lactate is the most abundant enantiomer of lactate. As plasma and urinary levels of L-lactate is associated with inherited metabolic disorders in general, D-lactate have been linked to the presence of diabetes and inflammatory bowel disease. Previously developed techniques have shown several limitations to further evaluate D-lactate as a biomarker for this condition. In this paper, we describe a highly sensitive, specific and fast liquid chromatography tandem mass spectrometry (LC-MS/MS) method for the analysis of D-, L-lactate in urine. Methods: D- and L-lactate were quantified using high performance liquid chromatography tandem mass spectrometry (LC-MS/MS) with labelled internal standard. Samples were derivatized with (+)-O,O'-diacety-L-tartaric anhydride (DATAN) and seperated on a Poroshell 120 EC-C18 column. Results: Quantitative analysis of D-, and L-lactate was achieved successfully. Calibration curves were linear (r>0.999) over $0.5-100{\mu}g/mL$. Stabilities for samples were within the 10% varation. Inter- and Intra-day assay variations were below 10%. Conclusion: The presented method proved to be suitable for the quantitation of D- and L-lactate and opens the possibility to explore the use of D-lactate as a biomarker.

Analysis of residual neomycin in honey by LC-MS/MS (LC-MS/MS에 의한 벌꿀 중 잔류 네오마이신의 분석)

  • Shim, Young-Eun;Jeong, Ji-Yoon;Myung, Seung-Woon
    • Analytical Science and Technology
    • /
    • v.22 no.4
    • /
    • pp.319-325
    • /
    • 2009
  • An effective and specific procedure for confirmation of neomycin, aminoglycoside antibiotic in honey was developed and validated. Honey was adjusted to pH 2 with 0.1M HCl and applied to weak cation-exchange SPE cartridge. Neomycin was eluted with basified methanol. Following separation by ion-pairing liquid chromatography, neomycin was analysed with positive electrospray ionization and MRM mode. Quantification was linear over the range of $5.0{\sim}250.0{\mu}g/kg$ ($r^2$ >0.9951). The precision (R.S.D.) and accuracy (as a bias) of quality control samples in honey ranged 11.5~18.7% and 10.9~20.9%, respectively. Established method can be applied to analysis of neomycin in honey.

Food safety analytical techniques used in food industry (식품산업에서 활용되는 식품안전 분석기술의 현황)

  • Kim, Young-Jun
    • Food Science and Industry
    • /
    • v.51 no.1
    • /
    • pp.16-25
    • /
    • 2018
  • Recently, the importance of analytical techniques related to food safety is emerging in the food industry due to changes in diet patterns, environmental changes, climate change and consumer's interest in food safety. In particular, food safety accidents in the food industry may cause economic losses such as media reports, product recalls, consumer distrust, and so on. Therefore, a systematic, proactive and comprehensive food safety management system is increasingly required to prevent food safety issues. Efforts to ensure the reliability of food safety are essential by introducing various analysis instruments such as LC, GC, ICP, LC/MS/MS, GC/MS/MS, ICP/MS, PCR, and RT-PCR. In addition, recent food safety analytical techniques used in food industry should be shifted paradigm by developing multi-component simultaneous analytical method, low cost with high efficient analytical method, and eco-friendly method.